scholarly journals Plasma 99th Percentile Reference Limits for Cardiac Troponin and Creatine Kinase MB Mass for Use with European Society of Cardiology/American College of Cardiology Consensus Recommendations

2003 ◽  
Vol 49 (8) ◽  
pp. 1331-1336 ◽  
Author(s):  
Fred S Apple ◽  
Heidi E Quist ◽  
Patrick J Doyle ◽  
Angela P Otto ◽  
MaryAnn M Murakami

Abstract Background: The European Society of Cardiology/American College of Cardiology (ESC/ACC) consensus document for definition of myocardial infarction (MI) is predicated on increased cardiac troponin or creatine kinase (CK) MB mass above the 99th percentile reference limit. The purpose of this study was to determine the plasma (heparin) 99th percentile reference limits for the leading in vitro diagnostic cardiac troponin and CKMB mass assays. Methods: Blood (heparin plasma) was obtained from healthy adults (n = 696; age range, 18–84 years) stratified by gender and ethnicity. Cardiac troponin I (cTnI) and T (cTnT) and CKMB mass concentrations were measured by eight assays. Reference limits were determined by nonparametric statistical analysis. Results: Two cTnI assays demonstrated at least a 1.2- to 2.5-fold higher 99th percentile for males vs females, with the mean concentrations significantly higher for males (P <0.05). Two cTnI assays also demonstrated a 1.1- to 2.8-fold higher 99th percentile for blacks vs Caucasians, with the mean concentrations significantly higher for blacks (P = 0.05). There was a 13-fold variance between the lowest measured 99th percentile (0.06 μg/L) and the highest (0.8 μg/L). All CKMB assays demonstrated a 1.2- to 2.6-fold higher 99th percentile for males vs females, with mean concentrations significantly higher for males (P <0.0001). Four CKMB assays also showed significantly higher (1.2- to 2.7-fold) mean concentrations for blacks (P <0.02) vs Caucasians. Conclusions: The heparin-plasma 99th percentile reference limits for cardiac troponin and CKMB mass provide an evidence base in support of the ESC, ACC, and American Heart Association guidelines for detection of myocardial injury. Selective gender and ethnic differences were demonstrated. These data allow clinicians, trialists, and epidemiologists a common point for operational use.

2021 ◽  
pp. 096032712110434
Author(s):  
Yusuf K Tekin ◽  
Gülaçan Tekin ◽  
Naim Nur ◽  
İlhan Korkmaz ◽  
Sefa Yurtbay

Introduction The present study was undertaken to investigate the prognostic value of the frontal QRS-T angle associated with adverse cardiac outcomes in patients with carbon monoxide (CO) poisoning in early stages in the emergency department. Materials and methods The data of 212 patients with CO poisoning who were admitted to the ED between January 2010 and May 2020 were retrospectively analyzed. The frontal QRS-T angle was obtained from the automatic reports of the EKG device. Results Compared to patients without myocardial damage, among patients with myocardial damage, statistically high creatinine, creatine kinase MB, cardiac troponin I, and frontal QRS-T angle values were found ( p < 0.001 for all parameters), while the saturation of arterial blood pH and arterial oxygen values were found to be lower ( p = 0.002 and p < 0.001, respectively). The frontal QRS-T angle values were correlated with creatine kinase, creatine kinase-MB, cardiac troponin I, and oxygen saturation (SpO2) in arterial blood (r = 0. 232, p = 0.001; r = 0. 253, p = < 0.001; r = 0. 389, p = < 0.001; r = −0. 198, p = 0.004, respectively). The optimum cut-off value of the frontal QRS-T angle was found to be 44.5 (area under the curve: 0.901, 95% confidence interval: 0.814–0.988, sensitivity: 87%, specificity: 84%). Conclusions The frontal QRS-T angle, a simple and inexpensive parameter that can be easily obtained from 12-lead surface electrocardiography, can be used as an early indicator in the detection of myocardial damage in patients with CO poisoning.


1999 ◽  
Vol 45 (6) ◽  
pp. 822-828 ◽  
Author(s):  
David J Newman ◽  
Yemi Olabiran ◽  
William D Bedzyk ◽  
Suzette Chance ◽  
Eileen G Gorman ◽  
...  

Abstract Background: Available assays for cardiac troponin I (cTnI) yield numerically different results. The aim of this study was to compare patient values obtained from four cTnI immunoassays. Methods: We studied the Stratus® II assay, the Opus® II assay, the Access® assay, and a research-only cTnI heterogeneous immunoassay that uses the Dade Behring aca® plus immunoassay system equipped with two new noncommercial monoclonal antibodies. Because the aca plus cTnI assay is for research only, we first evaluated and analytically validated it for serum and citrated plasma. Initially, each method was calibrated using the method-specific calibrator supplied by each manufacturer; however, the aca plus cTnI assay was calibrated using patient serum pools containing cTnI and selected on the basis of increased creatine kinase MB isoenzyme and with values assigned by use of the Stratus cTnI assay. For method comparisons, individual patient sample cTnI values were determined and compared with the Stratus II assay. Results: Passing and Bablock regression analysis yielded slopes of 1.44 (r = 0.96; n = 72) for the Opus II vs Stratus II assays; 0.07 (r = 0.91; n = 72) for the Access vs Stratus II assays; and 0.90 (r = 0.91, n = 72) for the aca plus vs Stratus II assays. The recalibration of each method with a Stratus II-assigned serum pool improved, but did not entirely eliminate, the slope differences between the different assays (range, 1.00–1.16). The observed scatter in the correlation curves remained. Conclusion: There is a need to further explore the specificities of these assays with respect to the different circulating forms of cTnI.


1994 ◽  
Vol 40 (7) ◽  
pp. 1291-1295 ◽  
Author(s):  
J E Adams ◽  
K B Schechtman ◽  
Y Landt ◽  
J H Ladenson ◽  
A S Jaffe

Abstract Although measurement of cardiac troponin I (cTnI) is, in some situations, more specific for detection of cardiac injury than is measurement of the MB isoenzyme of creatine kinase (MBCK), its sensitivity and specificity relative to MBCK for detection of myocardial infarction has not been established. Accordingly, we studied prospectively 199 consecutive patients admitted to the coronary care unit. Values of MBCK and cTnI mass were determined in all samples. Of the 188 patients admitted with a suspicion of acute myocardial ischemia, 89 were diagnosed as having an acute myocardial infarction on the basis of the patterns of MBCK values. Eighty-six of these patients also had increased cTnI (concordance, 96.6%); three did not. Of the patients diagnosed as without infarction, five with unstable angina and symptoms in the day(s) prior to admission had increased cTnI, for a cTnI specificity of 94.9%. Receiver operating characteristic curve analysis indicated that cTnI and MBCK had statistically indistinguishable diagnostic accuracies for the detection of acute myocardial infarction.


1997 ◽  
Vol 134 (4) ◽  
pp. 622-630 ◽  
Author(s):  
Milenko J. Tanasijevic ◽  
Christopher P. Cannon ◽  
Donald R. Wybenga ◽  
George A. Fischer ◽  
Christine Grudzien ◽  
...  

1997 ◽  
Vol 4 (1) ◽  
pp. 6-12 ◽  
Author(s):  
Gerard X. Brogan ◽  
Judd E. Hollander ◽  
Charles F. McCuskey ◽  
Henry C. Thode ◽  
Jeffrey Snow ◽  
...  

Angiology ◽  
2001 ◽  
Vol 52 (5) ◽  
pp. 317-322 ◽  
Author(s):  
Niyazi Güler ◽  
Mehmet Bilge ◽  
Beyhan Eryonucu ◽  
Kürcat Uzun ◽  
Mehmet Emin Avci ◽  
...  

Cardiac troponin levels are regarded as the most specific of currently available biochemical markers of myocardial damage. Elevated levels of troponin have been previously reported in patients with left heart failure, reflecting small areas of undetected myocardial cell death. The aim of this study was to compare the levels of the cardiac troponin I (cTnl) in patients with left- and right-sided heart failure. Cardiac troponin I levels were studied with immunochemical methods in patients with right heart failure (n = 17) resulting from chronic obstructive pulmonary disease, ischemic left heart failure (n = 23), and nonischemic left heart failure (n = 18) who were admitted to departments of cardiology and chest diseases. Also, cTnl levels were measured in 32 healthy subjects as control group. Protein markers of myocardial injury (cTnl and myoglobin) in patients with left and right heart failure were collected approximately 12 to 36 hours after onset of obvious symptoms. Serum creatine kinase MB band was determined on admission and thereafter twice a day during the first 3 days. Elevated levels of serum cTnl were found in patients with nonischemic (0.83 ±0.6 ng/mL, p<0.01) and ischemic left heart failure (0.9 ±0.5 ng/mL, p<0.01) when compared to healthy subjects, whereas serum cTnl levels in patients with right heart failure due to chronic obstruc tive pulmonary disease were not significantly different from those of control subjects (0.22 ±0.1 vs 0.16 ±0.1 ng/mL, p> 0.05). In addition, creatine kinase MB band and myoglobin levels were not significantly different between patient and healthy groups. The mean of cTnl levels in ischemic and even nonischemic left heart failure were increased compared to the mean of values in healthy individuals but without significant creatine kinase MB band and myoglobin elevations. But cTnl levels were not increased in patients with right heart failure due to chronic obstructive pulmonary disease. These data indicate that the cTnl levels are abnormal in left heart failure but not in cor pulmonale.


Author(s):  
Maha A. Hilal ◽  
Sharaf E. D. Mahmoud ◽  
Meray M. Shokry ◽  
Ahmed M. Said

Background: In spite speedy development of clinical toxicology researches and protocols cardiovascular failure in severe acute intoxication remains a leading cause of death. Early cardiovascular risk assessment in acutely intoxicated patients is a must nowadays. This study aims to evaluate the role of ECG, serum cardiac troponin I (cTnI) and creatine kinase myocardial band (CK-MB) for early detection of cardio-toxicity in acutely poisoned patients. Methods: Prospective study was carried on100 patients with acute cardiotoxicity by drugs and toxins known to cause cardiac injury admitted to Sohag University hospitals, informed written consent has been obtained from each patient; ECG and biochemical analysis of serum cTnI and CK-MB were estimated in all studied patients. Results: (90%) of studied patients had complete free recovery, (4%) discharged with complications and (6%) of patients died. ECG test can be used as a predictor of mortality and had sensitivity 100%, specificity 46.8% and negative predictive value (NPV) 100%. Serum cTnI was highly significantly increased with death hence could be used as predictors of outcome. While serum CK-MB couldn't be used as an outcome predictor. ROC curve analysis to assess serum cTnI as a predictor of mortality of acute cardiovascular toxicity with cut off > 1.0 ng/ml had sensitivity 100%, specificity 89.4% and NPV 100% with excellent diagnostic characteristic (accuracy rate 96.4%). There is no significant difference of serum CK-MB and serum cTnI among cardiac drugs toxicity patients and non-cardiac toxins patients. Conclusion: the study concluded that ECG and serum cTnI can be used as a predictor of mortality. Also, the protocol of management will be same in acute cardiotoxicity by cardiac drugs and non-cardiac drugs and toxins. Recommendation: the study recommends combining of ECG changes and serum cTnI as they can early detect acute cardiovascular effects in acutely poisoned patients.


Sign in / Sign up

Export Citation Format

Share Document