scholarly journals Response Surface Design for the Optimization of the Removal of Chlorella pyrenoidosa Low Frequency Ultrasonic Irradiation

2013 ◽  
Vol 25 (1) ◽  
pp. 202-208 ◽  
Author(s):  
Gongduan Fan ◽  
Zhi Zhang ◽  
Jing Luo ◽  
Xin Wan ◽  
Chao Liu
2011 ◽  
Vol 295-297 ◽  
pp. 1860-1865 ◽  
Author(s):  
Zhi Zhang ◽  
Chao Liu ◽  
Gong Duan Fan ◽  
Jing Luo ◽  
Yan Dong Wang

The control parameters of the removal of Chlorella pyrenoidosa, which was irradiated by low frequency ultrasonic, is optimized by using single factor experiments and response surface methodology (RSM). First of all, the approximate ranges of the ultrasonic frequency, the ultrasonic power and the irradiation time were estimated with single factor experiments for the further experiments. And then the optimized values of the three control parameters were determined, which were analyzed by using central composite design (CCD) and RSM. The results showed that the removal rate of chlorophyll-a could reach to 64.1% after the irradiation for 6.34min by using ultrasonic of 77.7 kHz and 250W. Ultrasonic technology can remove Chlorella pyrenoidosa cells in water quickly and effectively, so as to achieve the purpose of water purification.


2014 ◽  
Vol 26 (20) ◽  
pp. 6967-6974
Author(s):  
Gongduan Fan ◽  
Qian Lin ◽  
Jing Luo ◽  
Jieyun Chen ◽  
Liru Chen ◽  
...  

2021 ◽  
pp. 1-37
Author(s):  
Ana Gabriela Sierra-Sánchez ◽  
Verónica Martínez-Miranda ◽  
Elia Alejandra Teutli-Sequeira ◽  
Ivonne Linares-Hernández ◽  
Guadalupe Vázquez-Mejía ◽  
...  

2019 ◽  
Vol 62 (5) ◽  
pp. 1251-1258 ◽  
Author(s):  
Yu Liu ◽  
Chaoyuan Wang ◽  
Zhengxiang Shi ◽  
Baoming Li

Abstract. A wash cycle using an alkaline solution with a dissolved chemical detergent is a standard clean-in-place (CIP) process for cleaning milking systems. However, long-term chemical use may corrode equipment and create difficulties in wastewater treatment. This study investigated the potential for using alkaline electrolyzed oxidizing (EO) water as an alternative to alkaline chemical detergent for removal of microorganisms and adenosine triphosphate (ATP) on milking system materials. Laboratory trials were performed based on a Box-Behnken response surface design to assess the cleaning effect of alkaline EO water on three materials typically used in milking systems: stainless steel, rubber gasket, and polyvinyl chloride (PVC) hose. Results showed that alkaline EO water treatment was generally enhanced with increased treatment time, temperature, and pH, and their interaction effects were also observed in ATP removal. However, treatment time did not have a dominant role in cleaning PVC hose. Response surface models were developed to reliably predict detected microorganisms and relative light units (RLU) on the three materials after alkaline EO water treatment. Based on the response surface models, the three parameters for alkaline EO water cleaning were optimized as treatment time of 10.0 min, temperature of 61.8°C, and pH of 12, after which microorganisms and RLU were nearly undetectable. Alkaline EO water treatment with the optimized parameters had an equivalent or better cleaning ability compared to the commercial detergent, suggesting its potential as a cleaning and bacteria removal agent for milking systems. Keywords: Alkaline electrolyzed oxidizing water, Cleanliness, Milking system, Response surface model.


Sign in / Sign up

Export Citation Format

Share Document