scholarly journals In vitro evaluation of marginal fit of zirconia-reinforced lithium silicate laminate veneers at two thicknesses using different CAD/CAM systems

2020 ◽  
Vol 23 (4) ◽  
pp. 9p
Author(s):  
Manar Ahmed El-Mahdy ◽  
Ahmed Khaled Aboelfadl ◽  
Marwa Mohamed Wahsh

ABSTRACTObjective: The purpose of this in vitro study was to evaluate the marginal fit of laminate veneers made of zirconia-reinforced lithium silicate with two thicknesses using different CAD/CAM systems. Material and methods: 42 Laminate veneers milled from zirconia-reinforced lithium silicate were divided into three main groups according to milling machine used into: group X5, laminate veneers fabricated by inLab MCX5 milling machine; group CM, laminate veneers fabricated by Ceramill motion 2; and group XL, laminate veneers fabricated by inLab MCXL. Each group was divided into two subgroups according to veneer thickness into: subgroup I, 0.5 mm thickness laminate veneers and subgroup II, 0.3 mm thickness laminate veneers. The marginal fit was measured using stereomicroscope. The results were tabulated and statistically analyzed using two-way ANOVA test followed by Tukey’s post hoc test. Comparisons of main and simple effects were done utilizing Bonferroni correction (P ? 0.05). Results: The mean (±SD) highest marginal discrepancy was recorded in subgroup BII at 85.45±1.82 µm while the least mean marginal discrepancy was recorded in subgroup AI 71.24±2.64 µm. Conclusion: Both thicknesses (0.5 mm thickness and 0.3 mm thickness) and all tested CAD/CAM systems produced zirconia-reinforced lithium silicate laminate veneers with clinically acceptable marginal gaps; however, the closed CAD/CAM systems produced veneers with superior marginal fit than open systems at 0.3 mm thickness. The CAD/CAM system with the 5-axis milling machine produced the best marginal fit with 0.5 mm thickness. KEYWORDS Marginal fit; Zirconia-reinforced lithium silicate; Laminate veneers; CAD/CAM; Milling machines. RESUMOObjetivo: O objetivo deste estudo in vitro foi avaliar a adaptação marginal de facetas laminadas de silicato de lítio reforçado com zircônia com duas espessuras, utilizando diferentes sistemas CAD / CAM. Material e métodos: 42 facetas laminadas fresadas a partir de silicato de lítio reforçado com zircônia foram divididos em três grupos principais de acordo com a fresadora usada em: grupo X5, facetas laminadas fabricados pela fresadora inLab MCX5; grupo CM, facetas laminadas fabricados por Ceramill motion 2; e grupo XL, facetas laminadas fabricados pelo inLab MCXL. Cada grupo foi dividido em dois subgrupos, de acordo com a espessura do laminado, em: subgrupo I, facetas laminadas com 0,5 mm de espessura e subgrupo II, facetas laminadas com espessura de 0,3 mm. A adaptação marginal foi medida usando estereomicroscópio. Os resultados foram tabulados e analisados estatisticamente usando o teste ANOVA de dois fatores seguido pelo teste post hoc de Tukey. Comparações dos efeitos principais e simples foram realizadas utilizando a correção de Bonferroni (P ?0,05). Resultados: A maior discrepância marginal média (± DP) foi registrada no subgrupo BII em 85,45 ± 1,82 µm, enquanto a menor discrepância marginal média foi registrada no subgrupo AI 71,24 ± 2,64 µm. Conclusão: Ambas as espessuras (0,5 mm e 0,3 mm) e todos os sistemas CAD / CAM testados produziram facetas de laminado de silicato de lítio reforçadas com zircônia com lacunas clinicamente aceitáveis. No entanto, os sistemas CAD / CAM fechados produziam facetas com adaptação marginal superior aos sistemas abertos com 0,3 mm de espessura. O sistema CAD / CAM com a fresadora de 5 eixos produziu a melhor adaptação marginal com 0,5 mm de espessura.PALAVRAS-CHAVE Adaptação marginal; Silicato de lítio reforçado com zircônia; Facetas laminados; CAD / CAM; Fresadoras.

2015 ◽  
Vol 15 (2) ◽  
pp. 173 ◽  
Author(s):  
Srinivasan Jayaraman ◽  
BalajiN Rajan ◽  
Baburajan Kandhasamy ◽  
Ilangkumaran Rajakumaran

2019 ◽  
Vol 64 (2) ◽  
pp. 207-214 ◽  
Author(s):  
Syed Rashid Habib

Abstract Objective: The aim of this in vitro research study was to evaluate the vertical marginal discrepancies of zirconia (Zr) cores fabricated by five different computer-aided design and manufacturing (CAD/CAM) systems using a digital microscope. Materials and methods: A total of 60 specimens were prepared and randomly divided into five groups (n=12 each) using the following systems: Ceramill Motion 2 (CM, Amanngirrbach, Germany); Weiland (WI, Ivoclar Vivadent, USA); Cerec (CS, Sirona Dental, USA); Zirkonzahn (ZZ, Gmbh Bruneck, Italy) and Cad4dent (CD, Canada). The specimens were numbered and the vertical marginal discrepancies were evaluated with a digital microscope at 50× magnification. Results: A one-way analysis of variance showed a statistically significant difference (p=0.002) between the groups. The CM group exhibited the lowest values for the marginal gaps (31.30±15.12 μm), while the ZZ group exhibited the highest values for the marginal gaps (44.83±28.76 μm) compared to other groups. A post hoc Tukey’s test for multiple comparisons between the experimental groups showed a statistically significant difference (p<0.05) between the group CM and group CD with group ZZ. The rest of the groups showed no significant differences between them. Variations in the values were observed for the four sites measured with the highest and the least mean marginal gap value of 43.19±23.84 μm and 32.49±12.21 μm for buccal and lingual sites, respectively. Conclusion: Variations existed in the marginal discrepancy values for the CAD/CAM systems investigated in the study. Vertical marginal discrepancy values observed for various systems investigated in the study were well within the clinically acceptable range.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2020 ◽  
pp. 194338752095268
Author(s):  
Robin Kasper ◽  
Karsten Winter ◽  
Sebastian Pietzka ◽  
Alexander Schramm ◽  
Frank Wilde

Study Design: An experimental in vitro study. Objective: Plate fractures are a recurrent problem in alloplastic mandibular reconstruction. Hypothetically it can be assumed that computer-aided design (CAD)/computer-aided manufacturing (CAM) reconstruction plates have a higher stability than conventional hand-bent plates. The aim of the study was to compare additive and subtractive fabricated CAD/CAM mandibular reconstruction plates as well as conventional plates with regard to their biomechanical properties. Methods: In a chewing simulator, plates of 2 conventional locking plate systems and 2 CAD/CAM-fabricated plate systems were compared. The plates were loaded in a fatigue test. The maximum number of cycles until plate fracture and the plate stiffness were compared. Results: While all conventional plates fractured at a maximum load between 150 and 210 N (Newton) after a number of cycles between 40 000 and 643 000, none of the CAD/CAM plates broke despite a nearly doubled load of 330 N and 2 million cycles. Both CAD/CAM systems proved to be significantly superior to the hand-bent plates. There was no difference between the 2 CAD/CAM systems. Conclusions: Concerning the risk of plate fracture, patient-specific CAD/CAM reconstruction plates appear to have a significant advantage over conventional hand-bent plates in alloplastic mandibular reconstruction.


2005 ◽  
Vol 13 (2) ◽  
pp. 120-125 ◽  
Author(s):  
Diego Klee de Vasconcellos ◽  
Marco Antonio Bottino ◽  
Renato Sussumu Nishioka ◽  
Luiz Felipe Valandro ◽  
Elza Maria Valadares da Costa

OBJECTIVES: The present in vitro study was designed to compare the differences in the vertical misfit of implant-supported frameworks using three different forces for tightening the bridge locking screws: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. METHODS: The investigation was conducted based on the results given by 9 six-unit nickel-chromium (2 abutments/ 4 pontics) screw-retained implant-supported frameworks. The structures were exposed to simulated porcelain firings. The marginal misfit measurements were made using a traveling measuring microscope at selected screw tightening forces: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. The results were submitted to one-way ANOVA with repeated measures on one factor, and post hoc pairwise comparisons using Tukey test (5%). RESULTS: The mean marginal misfit of the frameworks, fastening the screws by hand until first resistance, was 41.56µm (SD±12.45µm). The use of torque driver devices caused a significant reduction in marginal opening (p<0.05). With the lowest torque available (10Ncm), the mean marginal discrepancy at the abutment-framework interface was reduced an average of 52% to a mean marginal opening of 19.71µm (SD±2.97µm). After the use of the 20Ncm torque driver, the mean marginal discrepancy of the frameworks was reduced an average of 69% to a mean marginal opening of 12.82µm (SD±4.0µm). Comparing the use of torque drivers with 10 and 20 Ncm torque, the means are not significantly different from one another. CONCLUSION: The seating force has an important effect on the vertical misfit measurements, once it may considerably narrow the vertical misfit gaps at the abutment-framework interface, thus leading to a misjudgment of the real marginal situation.


2017 ◽  
Vol 61 (2) ◽  
pp. 177-184 ◽  
Author(s):  
Bálint Vecsei ◽  
Gellért Joós-Kovács ◽  
Judit Borbély ◽  
Péter Hermann

Sign in / Sign up

Export Citation Format

Share Document