Temperature Acquisition System for Real Time Application of First Velocity Correction by EDM (Electronic Distance Measurement)

2021 ◽  
Vol 8 (1) ◽  
pp. 61-74
Author(s):  
Felipe Andrés Carvajal Rodriguez ◽  
Luis Augusto Koenig Veiga ◽  
Wilson Alcântara Soares

The first velocity correction is used to correct the measured distance affected by the velocity variation of the electromagnetic wave propagation in a medium. This correction depends on the refractive index of the propagation medium and reference refractive index. The influence of the temperature in the medium refractive index is critical; some estimates establish that variation 1°C causes 1ppm of error in distances. In the measuring processes with total stations, the temperature is usually collected at only one point, for example, in the position where the measuring instrument is setup. However, the wave propagates in a medium of non-constant temperature, where the extremes of the line can present variations and thus this measurement in only one point could be non-representative. In this context, it was developed a low-cost real-time temperature acquisition system. This system provides the temperature values in different locations allowing their monitoring through the time. Experiments realized during the geodetic monitoring of a dam, show variations up to 8°C among geodetic points on the dam and around it. An analysis was development to evaluate the influence of temperature variations on monitoring distances and geodetic coordinate of a 2d network with different approaches (temperature modeling).  The results shows different values for distances (1.0 mm) and coordinates (0.5 mm) depending of the approach choose.

Author(s):  
Cheyma BARKA ◽  
Hanen MESSAOUDI-ABID ◽  
Houda BEN ATTIA SETTHOM ◽  
Afef BENNANI-BEN ABDELGHANI ◽  
Ilhem SLAMA-BELKHODJA ◽  
...  

Author(s):  
V. Silva ◽  
T. Malheiro ◽  
J. A. Mendes ◽  
J. Cabral ◽  
A. Tavares

In this paper, the design of a real-time digital multi--channel ECG signal acquisition system is presented. With the purpose of fabrication towards a simple, compact and low-cost tool for bioelectrical signal processing laboratories, the system is developed to acquire the 12 leads EGC signals and converted to numerical data based on an Arduino module named as Leonardo equipped 12 channels ADC. To observe the EGC waves, the ECG signals are amplified through designed amplifiers with the gain of 60 dB. To reduce the effects from the DC component as well as the baseline wandering and the high frequency noise, the active analog bandpass filter ranged in 0,05 Hz to 100 Hz was designed. The power line noise of 50 Hz also decreased with an active analog bandstop filter with attenuation -38 dB. Under the PC application was built using Labview programing, the low-cost digital ECG signal acquisition system was demonstrated with the requirement of observation in real-time. To clarify the small wave in the digital EGG signal, the limitation of the analog signal processing is improved through the digital filters parameterized in the software to increase the SNR from 1.4 dB to 27.6 dB. Practically, the system is evaluated through a series of experiments on a volunteer person resulting the ECG data is recorded and stored in a TDMS file. Since the system is designed as opened-system, a series of developments towards various applications in biomedical diagnosis based on digital signal analysis techniques is promised to be feasible in the near future.


2020 ◽  
Vol 28 (19) ◽  
pp. 27337
Author(s):  
Devesh Barshilia ◽  
Lai-Kwan Chau ◽  
Guo-En Chang

Sign in / Sign up

Export Citation Format

Share Document