scholarly journals Multiplexed tandem mass spectrometry-based screening for five lysosomal storage disorders: A pilot study

Author(s):  
Rita Christopher
2017 ◽  
Vol 41 (2) ◽  
pp. 209-219 ◽  
Author(s):  
Alberto B. Burlina ◽  
Giulia Polo ◽  
Leonardo Salviati ◽  
Giovanni Duro ◽  
Carmela Zizzo ◽  
...  

2018 ◽  
Vol 41 (3) ◽  
pp. 457-477 ◽  
Author(s):  
Monique Piraud ◽  
Magali Pettazzoni ◽  
Pamela Lavoie ◽  
Séverine Ruet ◽  
Cécile Pagan ◽  
...  

2016 ◽  
Vol 62 (9) ◽  
pp. 1248-1254 ◽  
Author(s):  
Silvia Tortorelli ◽  
Coleman T Turgeon ◽  
Dimitar K Gavrilov ◽  
Devin Oglesbee ◽  
Kimiyo M Raymond ◽  
...  

Abstract BACKGROUND Newborn screening for lysosomal storage disorders (LSD) has revealed that late-onset variants of these conditions are unexpectedly frequent and therefore may evade diagnosis. We developed an efficient and cost-effective multiplex assay to diagnose six LSDs and several peroxisomal disorders in patients presenting with diverse phenotypes at any age. METHODS Three 3-mm dried blood spot (DBS) punches were placed into individual microtiter plates. One disc was treated with a cocktail containing acid sphingomyelinase-specific substrate and internal standard (IS). To the second DBS we added a cocktail containing substrate and IS for β-glucosidase, acid α-glucosidase, α-galactosidase A, galactocerebrosidase, and α-L-iduronidase. The third DBS was extracted with methanol containing d4-C26 lysophosphatidylcholine as IS and stored until the enzyme plates were combined and purified by liquid–liquid and solid-phase extraction. The extracts were evaporated, reconstituted with the extract from the lysophosphatidylcholine plate, and analyzed by flow injection tandem mass spectrometry. RESULTS Reference intervals were determined by analysis of 550 samples from healthy controls. DBS from confirmed patients with 1 of the 6 LSDs (n = 33), X-adrenoleukodystrophy (n = 9), or a peroxisomal biogenesis disorder (n = 5), as well as carriers for Fabry disease (n = 17) and X-adrenoleukodystrophy (n = 5), were analyzed for assay validation. Prospective clinical testing of 578 samples revealed 25 patients affected with 1 of the detectable conditions. CONCLUSIONS Our flow injection tandem mass spectrometry approach is amenable to high-throughput population screening for Hurler disease, Gaucher disease, Niemann–Pick A/B disease, Pompe disease, Krabbe disease, Fabry disease, X-adrenoleukodystrophy, and peroxisomal biogenesis disorder in DBS.


2016 ◽  
Vol 118 (4) ◽  
pp. 304-309 ◽  
Author(s):  
Susan Elliott ◽  
Norman Buroker ◽  
Jason J. Cournoyer ◽  
Anna M. Potier ◽  
Joseph D. Trometer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document