scholarly journals The use of computer-assisted surgery as an educational tool for the training of orthopedic surgery residents in pedicle screw placement: a pilot study and survey among orthopedic residents

2016 ◽  
Vol 59 (6) ◽  
pp. 391-398 ◽  
Author(s):  
Ahmed Aoude ◽  
Hamzah Alhamzah ◽  
Maryse Fortin ◽  
Peter Jarzem ◽  
Jean Ouellet ◽  
...  
2021 ◽  
Vol 34 (1) ◽  
pp. 127-134
Author(s):  
Andrew M. Gardeck ◽  
Xuan Pu ◽  
Qiuyu Yang ◽  
David W. Polly ◽  
Kristen E. Jones

OBJECTIVEResidency work-hour restrictions necessitate efficient, reproducible training. Simulation training for spinal instrumentation placement shows significant benefit to learners’ subjective and objective proficiency. Cadaveric laboratories are most effective but have high cost and low availability. The authors’ goal was to create a low-cost, efficient, reproducible spinal instrumentation placement simulation curriculum for neurosurgery and orthopedic surgery residents using synthetic models and 3D computer-assisted navigation, assessing subjective and objective proficiency with placement of thoracolumbar pedicle screws.METHODSFifteen neurosurgery and orthopedic surgery residents participated in a standardized curriculum with lecture followed by two separate sessions of thoracolumbar pedicle screw placement in a synthetic spine model utilizing 3D computer-assisted navigation. Data were collected on premodule experience, time and accuracy of screw placement, and both subjective and objective ratings of proficiency.RESULTSFifteen of 15 residents demonstrated improvement in subjective (Physician Performance Diagnostic Inventory Scale [PPDIS]) and 14 in objective (Objective Structured Assessment of Technical Skills [OSATS]) measures of proficiency in navigated screw placement with utilization of this curriculum (p < 0.001 for both), regardless of the number of cases of previous experience using thoracolumbar spinal instrumentation. Fourteen of 15 residents demonstrated decreased time per screw placement from session 1 to session 2 (p = 0.006). There was no significant difference in pedicle screw accuracy between session 1 and session 2.CONCLUSIONSA standardized curriculum using synthetic simulation training for navigated thoracolumbar pedicle screw placement results in significantly improved resident subjective and objective proficiency. Development of a nationwide competency curriculum using simulation training for spinal instrumentation placement should be considered for safe, efficient resident training.


Spine ◽  
2018 ◽  
Vol 43 (21) ◽  
pp. 1487-1495 ◽  
Author(s):  
Dejan Knez ◽  
Janez Mohar ◽  
Robert J. Cirman ◽  
Boštjan Likar ◽  
Franjo Pernuš ◽  
...  

Spine ◽  
1997 ◽  
Vol 22 (4) ◽  
pp. 452-458 ◽  
Author(s):  
Othmar Schwarzenbach ◽  
Ulrich Berlemann ◽  
Bernhard Jost ◽  
Heiko Visarius ◽  
Erich Arm ◽  
...  

2010 ◽  
Vol 13 (5) ◽  
pp. 606-611 ◽  
Author(s):  
Yoshimoto Ishikawa ◽  
Tokumi Kanemura ◽  
Go Yoshida ◽  
Zenya Ito ◽  
Akio Muramoto ◽  
...  

Object The authors performed a retrospective clinical study to evaluate the feasibility and accuracy of cervical pedicle screw (CPS) placement using 3D fluoroscopy-based navigation (3D FN). Methods The study involved 62 consecutive patients undergoing posterior stabilization of the cervical spine between 2003 and 2008. Thirty patients (126 screws) were treated using conventional techniques (CVTs) with a lateral fluoroscopic view, whereas 32 patients (150 screws) were treated using 3D FN. Screw positions were classified into 4 grades based on the pedicle wall perforations observed on postoperative CT. Results The prevalence of perforations in the CVT group was 27% (34 screws): 92 (73.0%), 12 (9.5%), 6 (4.8%), and 16 (12.7%) for Grade 0 (no perforation), Grade 1 (perforation < 1 mm), Grade 2 (perforation ≥ 1 and < 2 mm), and Grade 3 (perforation ≥ 2 mm), respectively. In the 3D FN group, the prevalence of perforations was 18.7% (28 screws): 122 (81.3%), 17 (11.3%), 6 (4%), and 5 (3.3%) for Grades 0, 1, 2, and 3, respectively. Statistical analysis showed no significant difference in the prevalence of Grade 1 or higher perforations between the CVT and 3D FN groups. A higher prevalence of malpositioned CPSs was seen in Grade 2 or higher (17.5% vs 7.3%, p < 0.05) in the 3D FN group and Grade 3 (12.7% vs 7.3%, p < 0.05) perforations in the CVT group. The ORs for CPS malpositioning in the CVT group were 2.72 (95% CI 1.16–6.39) in Grade 2 or higher perforations and 3.89 (95% CI 1.26–12.02) in Grade 3 perforations. Conclusions Three-dimensional fluoroscopy-based navigation can improve the accuracy of CPS insertion; however, severe CPS malpositioning that causes injury to the vertebral artery or neurological complications can occur even with 3D FN. Advanced techniques for the insertion of CPSs and the use of modified insertion devices can reduce the risk of a malpositioned CPS and provide increased safety.


2018 ◽  
Vol 2 (1) ◽  
pp. 01-04
Author(s):  
Anbis El Hakim

Objective: Evolving pressure on surgical education necessitates safe and efficient learning of techniques. We evaluated the effect of training year using anatomic, percutaneous fluoroscopy guided and computer navigated techniques on the accuracy of pedicle screw placement to attempt to determine if different modalities may be better suited for different levels of training. Methods: All instrumented thoracic and lumbar cases performed at Detroit Medical Center by the Neurosurgery Service between August 2012 and June 2013 were included.Cases had hardware verified by post-operative CT. Hardware placement was graded according to Mirza SK et al., grade 0 (within pedicle), grade 1 (< 2 mm breach), grade 2 (> 2 mm breach) , and grade 3 (extrapedicular). Pedicle screws were reviewed independently by a resident and attending surgeon. Rates of pedicle breach, EBL, length of case, pedicle size and pedicle starting point were all reviewed. Pedicles were analyzed on PACS system in axial views, using sagittal views to identify the correct level. Results: A total of 306 pedicle screws were evaluated in 36 patients. The overall rate of accurate pedicle screw placement among residents defined as Grade 0 or 1 placement was 86.8%.Fluoroscopically placed screws had significantly less breaches than anatomic screws 11% vs 20% (p = 0.03). Fluoroscopic cases had significantly less medial breeches (20%) than anatomic (50%) (p < 0.05) and computer assisted cases (73%) (p < 0.05). EBL values for fluoroscopic, anatomic and Body Tom cases were 425 cc, 720 cc, and 816 cc respectively. Resident level was found to be inversely proportional to breech rate (R squared 0.45). We did not see any clear difference in breach rate for resident level in different modalities. Conclusion: Supervised neurosurgical residents can place pedicle screws within published rates of acceptable breach. Interestingly our study revealed an inverse relationship between resident experience and pedicle screw accuracy. Fluoroscopic placement of pedicle screws compared to computer assisted and anatomic techniques results in lower medial breach rate and may be better suited for junior level residents.


Sign in / Sign up

Export Citation Format

Share Document