scholarly journals Risk of subsequent aortic dilatation is low in patients with bicuspid aortic valve and normal aortic root diameter at the time of aortic valve replacement

2010 ◽  
Vol 10 (4) ◽  
pp. 535-538 ◽  
Author(s):  
Victor Dayan ◽  
Leandro Cura ◽  
Leon Muñoz ◽  
Daniel Areco ◽  
Alejandro Ferreiro ◽  
...  
2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Massimiliano Sperandio ◽  
Chiara Arganini ◽  
Alessio Bindi ◽  
Armando Fusco ◽  
Carlo Olevano ◽  
...  

The aim of our study was to compare the results of the TTE (transthoracic echocardiography) with the results obtained by the ECG-gated 64 slices CT during the followup of patients with bicuspid aortic valve (BAV), after aortic valve replacement; in particular we evaluated the aortic root and the ascending aorta looking for a new algorithm in the followup of these patients. From January 1999 to December 2009 our attention was focused on 67 patients with isolated surgical substitution of aortic valve; after dismissal they were strictly observed. During the period between May and September 2010, these patients underwent their last evaluation, and clinical exams, ECG, TTE, and an ECG-gated-MDCT were performed. At followup TTE results showed an aortic root of 36.7±4 mm and an ascending aorta of 39.6±4.8 mm. ECG- gated CT showed an aortic root of 37.9±5.5 mm and an ascending aorta of 43.1±5.2. The comparison between preoperative and postoperative TTE shows a significant long-term dilatation of the ascending aorta while the aortic root diameter seems to be stable. ECG-gated CT confirms the stability of the aortic root diameter (38.2±5.3 mm versus 37.9±5.5  mm; <0.0001) and the increasing diameter value of the ascending aorta (40.2±3.9 mm versus 43.1±5.2 mm; P=0.0156). Due to the different findings between CT and TTE studies, ECG-gated CT should no longer be considered as a complementary exam in the followup of patients with BAV, but as a fundamental role since it is a real necessity.


2017 ◽  
Vol 25 (3) ◽  
pp. 192-198
Author(s):  
Pablo Straneo ◽  
Gabriel Parma ◽  
Natalia Lluberas ◽  
Alvaro Marichal ◽  
Gerardo Soca ◽  
...  

Background Bicuspid aortic valve patients have an increased risk of aortic dilatation. A deficit of nitric oxide synthase has been proposed as the causative factor. No correlation between flow-mediated dilation and aortic diameter has been performed in patients with bicuspid aortic valves and normal aortic diameters. Being a hereditary disease, we compared echocardiographic features and endothelial function in these patients and their first-degree relatives. Methods Comprehensive physical examinations, routine laboratory tests, transthoracic echocardiography, and measurements of endothelium-dependent and non-dependent flow-mediated vasodilatation were performed in 18 bicuspid aortic valve patients (14 type 1 and 4 type 2) and 19 of their first-degree relatives. Results The first-degree relatives were younger (36.7 ± 18.8 vs. 50.5 ± 13.9 years, p = 0.019) with higher ejection fractions (64.6% ± 1.7% vs. 58.4% ± 9.5%, p = 0.015). Aortic diameters indexed to body surface area were similar in both groups, the except the tubular aorta which was larger in bicuspid aortic valve patients (19.3 ± 2.7 vs. 17.4 ± 2.2 mm·m−2, p = 0.033). Flow-dependent vasodilation was similar in both groups. A significant inverse correlation was found between non-flow-dependent vasodilation and aortic root diameter in patients with bicuspid aortic valve ( R = −0.57, p = 0.05). Conclusions Bicuspid aortic valve patients without aortopathy have larger ascending aortic diameters than their first-degree relatives. Endothelial function is similar in both groups, and there is no correlation with ascending aorta diameter. Nonetheless, an inverse correlation exists between non-endothelial-dependent dilation and aortic root diameter in bicuspid aortic valve patients.


Sign in / Sign up

Export Citation Format

Share Document