scholarly journals Precision and trueness verification study of an Atellica system

Author(s):  
Alberto Vílchez Rodríguez ◽  
Julia González Cantó ◽  
Sara Esteve Poblador ◽  
Carmen Valldecabres Ortiz ◽  
Pedro L. Estela Burriel

AbstractObjectivesClinical laboratories should use only validated procedures. Precision is an important factor in the validation and verification of a new measurement procedure. Our objective was to verify the precision and trueness of different analysers used for the biochemical and immunochemical characterization of analytes.MethodsAdvia 1800®, Immulite®2000 and CentaurXP® analysers and the Atellica®Solution system were used. Five analytes were characterized biochemically, whereas another five analytes were characterized immunochemically. Imprecision was assessed using BioRad® and Siemens® control materials. Within-run and between-run imprecision were calculated by analysing three replicates of each control in a single run every day for five days. Bias was assessed using 40 samples of serum by the analysis of differences and linear regression.ResultsThe within-run and between-run imprecision values obtained with the new measurement procedure were lower than the ones claimed by the manufacturer for all the analytes studied. In the bias study, a proportional but not constant systematic error was observed in some analytes.ConclusionsThe coefficients of variation obtained with Atellica®Solution verified both, the imprecision specifications claimed by the manufacturer and by the laboratory. The conditions of calibration should be revised for some parameters and a wider range of samples should be used.

Diabetes ◽  
1986 ◽  
Vol 35 (5) ◽  
pp. 517-522 ◽  
Author(s):  
J. Hari ◽  
K. Yokono ◽  
K. Yonezawa ◽  
K. Amano ◽  
S. Yaso ◽  
...  

2003 ◽  
Vol 19 (6) ◽  
pp. 705-706
Author(s):  
C Ellenberger ◽  
C P Bartmann ◽  
H O Hoppen ◽  
J Kratzsch ◽  
H Aupperle ◽  
...  

1990 ◽  
Vol 265 (27) ◽  
pp. 16195-16204 ◽  
Author(s):  
M J Eaton ◽  
J W Chen ◽  
K N Kumar ◽  
Y Cong ◽  
E K Michaelis

1979 ◽  
Vol 16 (3) ◽  
pp. 665-670 ◽  
Author(s):  
Burt V. Bronk

Some inequalities for moments and coefficients of variation of probability densities over the positive real line are obtained by means of simple geometrical relationships. As an illustrative application rigorous bounds are obtained for the ratio of weight average to number average molecular weight for a large class of distributions of macromolecules, giving a more precise characterization of this empirical measure of heterogeneity.


1992 ◽  
Vol 20 (2) ◽  
pp. 379-382 ◽  
Author(s):  
J. W. Gurd ◽  
I. R. Brown ◽  
N. Bissoon ◽  
S. Cudmore ◽  
B. Ni ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document