Biomechanics of Ulnar Osteotomies and Plate Fixation

Author(s):  
JM Rayhack ◽  
SI Gasser ◽  
EL Milne ◽  
LL Latta
Keyword(s):  
1987 ◽  
Vol 20 (3) ◽  
pp. 559-572 ◽  
Author(s):  
Robert M. Kellman ◽  
Wilfried Schilli
Keyword(s):  

Author(s):  
Anil Pandey ◽  
Setul Shah ◽  
Deepak S Maravi ◽  
S Uikey

Introduction:- Extra-articular proximal tibial fractures account for 5–10 % of all tibial shaft fractures and it result from high-velocity trauma. Closed reduction with minimally invasive plating and locked intramedullary  nailing have been widely used for treatment of proximal tibia extraarticular fractures. Our pupose is to compare the pros and cons of these two methods. Materials and methods:- 22 patients were included in this study for a period of 2 years. Patients treated with IMN were kept in group A patients treated with percutaneus plating were kept in group B. Standard approach of nailing and plating were used and proper follow up were taken for next upcoming 1 year. Results:- Combined average age was 38years. Male were more commonly affected than female (13:8). Majority of fracture were of type A33. Operative time was < 2 hours in both groups. Less blood loss occurred during intramedullary nailing as compared to locking plate fixation. Surgical site infections (SSIs) were seen in two patients in the PTP group. Delayed union occurred in two patients in the IMN group. The average range of motion was 119.7(range 90-150, SD= 19.18) in group A and 115.2(range 80-150, SD = 17.28) in group B. Conclusion:- in treatment of proximal tibia extra articular fracture use of IMN and PTLCP gives comparable results. To validate this issue further a large sample size multicentric study is recommended   Key words: intramedullary nailing (IMN), Extraarticular tibialn fracture, Surgical site infection.


2020 ◽  
Vol 7 (3) ◽  
pp. 147-152
Author(s):  
Salman Ghaffari ◽  
◽  
Mehran Razavipour ◽  
Parastoo Mohammad Amini ◽  
◽  
...  

McCune-Albright Syndrome (MAS) is characterized by endocrinopathies, café-au-lait spots, and fibrous dysplasia. Bisphosphonates are the most prescribed treatment for reducing the pain but their long-term use has been associated with atypical fractures of cortical bones like femur in patients. We present a 23-year-old girl diagnosed with MAS. She had an atypical mid-shaft left femoral fracture that happened during simple walking. She also had a history of long-term use of alendronate. Because of the narrow medullary canal, we used 14 holes hybrid locking plate for the lateral aspect of the thigh to fix the fracture and 5 holes dynamic compression plate (instead of the intramedullary nail) in the anterior surface to double fix it, reducing the probability of device failure. With double plate fixation and discontinuation of alendronate, the complete union was achieved five months after surgery


2009 ◽  
Vol 30 (02) ◽  
pp. 142-149 ◽  
Author(s):  
Kevin E. Varner ◽  
Victoria Matt ◽  
Jerry W. Alexander ◽  
James D. Johnston ◽  
Shiraz Younas ◽  
...  

Author(s):  
Marcus Christian Müller ◽  
Michael Windemuth ◽  
Sophie Frege ◽  
Eva Nadine Striepens

Background: Chronic exposure to occupational ionising radiation is seen as one reason for elevated cancer prevalence. </P><P> Objective: The aim of this retrospective study was to evaluate radiation exposure of anaesthetists by real-time dosimetry. Methods: Data of 296 patients were analyzed. Ten types of trauma operation procedures including osteosynthesis of upper and lower extremity fractures and minimally invasive stabilisation of traumatic and osteoporotic vertebral fractures were accomplished. Evaluation was performed by an occupational dosimetry system, which visualises anaesthetists radiation exposure feedback compared to surgeons in real-time. Results: A significantly lower radiation exposure to anaesthetists compared to surgeons was observed in four types of operative procedures: Plate fixation of proximal humerus fractures, osteosynthesis of proximal femoral fractures, stabilisation of traumatic and osteoporotic vertebral fractures. In four types of operations (plate osteosynthesis of proximal humeral, distal radial and tibial fractures and intramedullary nailing of the clavicle), anaesthetists` amount of radiation exceeded one-third of the surgeons' exposure, especially if the C-arm tube was positioned close to the anaesthetists work station at the patients' head. Conclusion: By using the occupational radiation dose monitoring system, radiation exposure to anaesthetists was visualised in real-time during trauma operations. Radiation exposure of anaesthetists depends on the type of operation and the position of the C-arm. The system may help to increase anaesthetists` awareness concerning radiation exposure and to enhance compliance in using radiation protection techniques.


2007 ◽  
Vol 68 (3) ◽  
pp. 133-138 ◽  
Author(s):  
A. Nabhan ◽  
D. Pape ◽  
T. Pitzen ◽  
W.-I. Steudel ◽  
F. Bachelier ◽  
...  

2011 ◽  
Vol 93 (1) ◽  
pp. 57-60 ◽  
Author(s):  
DC Perry ◽  
DMG Machin ◽  
JA Casaletto ◽  
DJ Brown

INTRODUCTION Rupture of extensor pollicis longus (EPL) tendon is a recognised complication following volar plate fixation of distal radius fractures, usually from attrition caused by prominent screws. We sought to identify the screw holes in some of the most commonly used plates which may precipitate tendon injury. SUBJECTS AND METHODS Three fixed-angle volar locking plates were sequentially positioned into 18 cadaveric arms. A wire was passed through each of the holes in the plates using a locking guide and the dorsal relationships noted. RESULTS Each plate had specific ‘high-risk’ holes which directed the wire towards the EPL groove. The central screw holes appeared mostly implicated in EPL injury. CONCLUSIONS Awareness of ‘high-risk’ holes and appropriate minor alterations in surgical technique may consequently decrease the incidence of EPL irritation and rupture.


Author(s):  
Hai-Yun Yang ◽  
Yun-Ge Zhang ◽  
Dong Zhao ◽  
Gui-Ming Sun ◽  
Yi Ma ◽  
...  

Abstract Background and Study Aim Cervical spondylotic myelopathy (CSM) is a common degenerative disease that mainly occurs in elder patients, leading to different degrees of neurological dysfunction. Spinal cord involvement is mainly distributed at the C3–C7 segments, but it may also involve up to the C2 level. This study aimed to assess the clinical efficacy and safety of open-door laminoplasty using a new extensor attachment-point reconstruction technique for treating CSM involving the C2 segment. Patients and Methods Fifty-nine patients with CSM involving the C2 segment and undergoing open-door laminoplasty were included in this retrospective study. Based on the titanium plate used in the operation, patients were divided into two groups, a reconstructed titanium plate fixation (RPF) group (n = 28) and a conventional titanium plate fixation (CPF) group (n = 31). Improvements in neurological function, cervical range of motion (ROM), cervical curvature index (CCI), preservation of posterior cervical muscle mass, and axial symptoms were compared between the two groups. Results There were no significant differences in operative time and intraoperative blood loss between the groups (p > 0.05). The Japanese Orthopaedic Association (JOA) score significantly increased in both groups postsurgery (p < 0.05); the neurological recovery rate was similar between the two groups (64.1 ± 13.3% vs. 65.9 ± 14.7%, p > 0.05). There was no significant loss of cervical ROM in either group (p > 0.05). The anteroposterior dural sac diameter at the C2 level was significantly enlarged in both groups (p < 0.05). Alternatively, CCI was significantly reduced in the CRP group (p < 0.05) but unchanged in the RPF group (p > 0.05). The cross-sectional area of the posterior cervical muscles was also significantly reduced in the CPF group (p < 0.05) but maintained in the RPF group (p > 0.05). Finally, axial symptoms were more severe in the CPF group than in the RPF group (p < 0.05). Conclusion Laminoplasty is an effective surgical procedure for CSM involving the C2 segment. The reconstructed titanium plate achieved superior maintenance of cervical curvature and reduced both muscle atrophy and severity of axial symptoms compared with titanium conventional plates.


Hand Clinics ◽  
2021 ◽  
Vol 37 (2) ◽  
pp. 259-266
Author(s):  
Lili E. Schindelar ◽  
Asif M. Ilyas

Sign in / Sign up

Export Citation Format

Share Document