Malignancy risk stratification in thyroid nodules according to the Bethesda system for reporting thyroid cytopathology

Author(s):  
Aldona Kowalska ◽  
Agnieszka Suligowska ◽  
Janusz Kopczynski ◽  
Kornelia Niemyska ◽  
Stanislaw Gozdz
Cancers ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 5581
Author(s):  
Nina Malika Popova ◽  
Maija Radzina ◽  
Peteris Prieditis ◽  
Mara Liepa ◽  
Madara Rauda ◽  
...  

Background: Various Thyroid Imaging and Reporting data systems (TIRADS) are used worldwide for risk stratification of thyroid nodules. Their sensitivity is high, while the specificity is suboptimal. The aim of the study was to compare several TIRADS systems and evaluate the effect of hypoechogenicity as a sign of risk of malignancy on the overall assessment of diagnostic accuracy. Methods: The prospective study includes 274 patients with 289 thyroid nodules to whom US and risk of malignancy were assessed according to four TIRADS systems—European (EU-TIRADS), Korean (K-TIRADS), TIRADS by American College of Radiology (ACR TIRADS), and modified Kwak et al. TIRADS (L-TIRADS) systems, in which mild hypoechogenicity is not included in malignancy risk suggestive signs. For all thyroid nodules, a fine needle aspiration (FNA) biopsy was performed and evaluated according to the Bethesda system. For all systems, diagnostic accuracy was calculated. Results: Assessing the echogenicity of the thyroid nodules: from 81 of isoechogenic nodules, 2 were malignant (2.1%), from 151 mild hypoechogenic, 18 (12%) were malignant, and from 48 marked hypoechogenic nodules, 16 (33%) were malignant. In 80 thyroid nodules, mild hypoechogenicity was the only sign of malignancy and none appeared malignant. Assessing various TIRADS systems on the same cohort, sensitivity, specificity, PPV, NPV, and accuracy, firstly for EU-TIRADS, they were 97.2%; 39.9%; 18.7%; 99.0%, and 73.3%, respectively; for K-TIRADS they were 97.2%; 46.6%; 20.6%; 99.2%, and 53.9%; for ACR-TIRADS they were 97.2%; 41.1%, 19.0%; 99.0%, and 48.0%, respectively; finally, for L-TIRADS they were 80.6%; 72.7%; 29.6%; 96.3%, and 73.3%. Conclusions: This comparative research has highlighted that applying different TIRADS systems can alter the number of necessary biopsies by re-categorization of the thyroid nodules. The main pattern that affected differences was inconsistent hypoechogenicity interpretation, giving the accuracy superiority to the systems that raise the malignancy risk with marked hypoechogenicity, at the same time with minor compensation for sensitivity.


2021 ◽  
Vol 3 (1) ◽  
pp. 1-7
Author(s):  
Ahmed K. Aly ◽  
Mahmoud A. Ali ◽  
Apoorva Sharma ◽  
Michael A. Gubbels ◽  
Xing Zhao ◽  
...  

Introduction: Thyroid nodules are very common. Many are detected incidentally due to increased head and neck imaging. The majority are benign; however, malignancy can’t be excluded in many cases and tissue sampling is needed. Ultrasound guided fine needle aspiration is an easy and effective way to sample g thyroid nodules. Inadequate sampling was reported in 10-40% of the cases. Rapid On-site Evaluation (ROSE) was proposed to assess obtained sample for adequacy. The aim of this study is to identify the benefit of applying ROSE with US-FNA of thyroid nodules within our institution. Materials and methods: Patients who underwent FNA for thyroid nodules with ROSE availability documented in their procedure note between January 2017 to December 2018 were retrospectively included. All procedures were done by experienced radiologists. Aspirated material was Diff Quik stained for immediate evaluation. The final cytological diagnosis and specimen adequacy was based on The Bethesda system for reporting thyroid cytopathology. Specimen adequacy was compared between ROSE and non-ROSE groups. Results: 442 thyroid nodules were biopsied. ROSE was available for 65 nodules. Non-diagnostic rate with ROSE was 10.8% compared to 13.8% without ROSE with the difference being statistically insignificant. ROSE availability improved sample adequacy of nodules less than 3 cm with statistically significant difference of 100.0% with ROSE vs. 87% without ROSE. Conclusion: The current study does not justify the routine use of ROSE. However, ROSE availability is beneficial with smaller sized thyroid nodules and less experienced radiologists performing the procedure. Doi: 10.28991/SciMedJ-2021-0301-1 Full Text: PDF


Surgery ◽  
2010 ◽  
Vol 148 (6) ◽  
pp. 1267-1273 ◽  
Author(s):  
Jennifer L. Rabaglia ◽  
Wareef Kabbani ◽  
Lucy Wallace ◽  
Shelby Holt ◽  
Lori Watumull ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document