Introduction: Thyroid nodules are very common. Many are detected incidentally due to increased head and neck imaging. The majority are benign; however, malignancy can’t be excluded in many cases and tissue sampling is needed. Ultrasound guided fine needle aspiration is an easy and effective way to sample g thyroid nodules. Inadequate sampling was reported in 10-40% of the cases. Rapid On-site Evaluation (ROSE) was proposed to assess obtained sample for adequacy. The aim of this study is to identify the benefit of applying ROSE with US-FNA of thyroid nodules within our institution. Materials and methods: Patients who underwent FNA for thyroid nodules with ROSE availability documented in their procedure note between January 2017 to December 2018 were retrospectively included. All procedures were done by experienced radiologists. Aspirated material was Diff Quik stained for immediate evaluation. The final cytological diagnosis and specimen adequacy was based on The Bethesda system for reporting thyroid cytopathology. Specimen adequacy was compared between ROSE and non-ROSE groups. Results: 442 thyroid nodules were biopsied. ROSE was available for 65 nodules. Non-diagnostic rate with ROSE was 10.8% compared to 13.8% without ROSE with the difference being statistically insignificant. ROSE availability improved sample adequacy of nodules less than 3 cm with statistically significant difference of 100.0% with ROSE vs. 87% without ROSE. Conclusion: The current study does not justify the routine use of ROSE. However, ROSE availability is beneficial with smaller sized thyroid nodules and less experienced radiologists performing the procedure. Doi: 10.28991/SciMedJ-2021-0301-1 Full Text: PDF

2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Aili Guo ◽  
Yuuki Kaminoh ◽  
Terra Forward ◽  
Frank L. Schwartz ◽  
Scott Jenkinson

Background. Fine needle aspiration (FNA) remains the first-line diagnostic in management of thyroid nodules and reduces unnecessary surgeries. However, it is still challenging since cytological results are not always straightforward. This study aimed to examine the results of thyroid FNA using the Bethesda system for reporting thyroid cytopathology (TBSRTC) to establish the level of accuracy of FNA procedures in a rural practice setting. Method. A retrospective chart review was conducted on existing thyroid FNA performed in a referral endocrine center between December 2011 and November 2015. Results. A total of 159 patients (18–88 years old) and 236 nodule aspirations were performed and submitted for evaluation. 79% were benign, 3% atypia/follicular lesion of unknown significance (AUS/FLUS), 5% follicular neoplasm/suspicious for follicular neoplasm (FN/SFN), 4% suspicious for malignancy (one case was indeed an atypical parathyroid neoplasm by surgical pathology), 2% malignant, and 7% nondiagnostic. Two cases also had advanced molecular analysis on FNA specimens before thyroidectomy. Conclusion. The diagnostic yield of FNA cytology from our practice in a rural setting suggests that accuracy and specificity are comparable to results from larger centers.


2016 ◽  
Vol 14 (2) ◽  
pp. 119-123 ◽  
Author(s):  
Antonio Rahal Junior ◽  
Priscila Mina Falsarella ◽  
Rafael Dahmer Rocha ◽  
João Paulo Bacellar Costa Lima ◽  
Matheus Jorge Iani ◽  
...  

ABSTRACT Objective To correlate the Thyroid Imaging Reporting and Data System (TI-RADS) and the Bethesda system in reporting cytopathology in 1,000 thyroid nodules. Methods A retrospective study conducted from November 2011 to February 2014 that evaluated 1,000 thyroid nodules of 906 patients who underwent ultrasound exam and fine needle aspiration. Results A significant association was found between the TI-RADS outcome and Bethesda classification (p<0.001). Most individuals with TI-RADS 2 or 3 had Bethesda 2 result (95.5% and 92.5%, respectively). Among those classified as TI-RADS 4C and 5, most presented Bethesda 6 (68.2% and 91.3%, respectively; p<0.001). The proportion of malignancies among TI-RADS 2 was 0.8%, and TI-RADS 3 was 1.7%. Among those classified as TI-RADS 4A, proportion of malignancies was 16.0%, 43.2% in 4B, 72.7% in 4C and 91.3% among TI-RADS 5 (p<0.001), showing clear association between TI-RADS and biopsy results. Conclusion The TI-RADS is appropriate to assess thyroid nodules and avoid unnecessary fine needle aspiration, as well as to assist in making decision about when this procedure should be performed.