scholarly journals Study on High-Precision Angle Sensor and Angle measurement Technology

2006 ◽  
Vol 126 (12) ◽  
pp. 1629-1636 ◽  
Author(s):  
Takaomi Kojima ◽  
Hiroyuki Wakiwaka
2017 ◽  
Vol 868 ◽  
pp. 99-104
Author(s):  
Wen Ying Zhang ◽  
Wei Hu Zhou ◽  
Da Bao Lao ◽  
Hao Ran Zhu

Cylindrical grating angle sensor is a common angle measuring device with high precision. Due to the reflecting arc surface of the cylindrical grating the effects of relative displacement of graduation line and gap variation will interact. Significant residual errors still exist even with high precision cylindrical grating and multiple reading heads around the scale disc .In this paper, based on the principle of circumference closure, the principle of self-calibration is deduced and analyzed in detail. The calibration curve is obtained by obtaining the deviation between the certain position and an ideal position of the graduation line position in real time. A simple self-calibration method of cylindrical grating is acquired. It can calibrate random errors and system errors with time and improve the angle measurement accuracy. The method has the advantages of simple structure and strong maneuverability, and provides technical means for the miniaturization and high precision of cylindrical grating.


2014 ◽  
Vol 1044-1045 ◽  
pp. 889-892
Author(s):  
Xin Lei Bi ◽  
Guo Wei Gao ◽  
Hong Sheng Pan ◽  
Ming Ming Chen

Based on SCA830 accelerometer designed a low cost high precision Angle measurement device. The device adopts the real-time mean shift filtering algorithms to reduce the interference of the external environment and noise, uses piecewise linearization method for Angle sensor calibration. The experimental results show that the designed angle detection device precision can reach 0.02 °, the system is stability, digital signal transmission is complete, and it can collect real-time carrier tilt Angle.


2014 ◽  
Vol 2014 (7) ◽  
pp. 53-59
Author(s):  
E Bezvesilna ◽  
◽  
Y Kyrychuk ◽  
S Nechai ◽  
R Bychuk

2014 ◽  
Vol 1065-1069 ◽  
pp. 2251-2254
Author(s):  
Fang Ru Gui

The analysis of the difficulties of structure measurement of a stadium and the application of total station instrument spatial measurement technology specifically solve the control and measurement of the steel structure installation, location survey of the pre component installation, and the technical problems in the process of calibration measurement, which has ensured that the accuracy of the entire steel structure construction.


Optik ◽  
2015 ◽  
Vol 126 (24) ◽  
pp. 4837-4840 ◽  
Author(s):  
Zhai Yusheng ◽  
Zhang Zhifeng ◽  
Su Yuling ◽  
Wang Xinjie ◽  
Feng Qibo

2013 ◽  
Vol 303-306 ◽  
pp. 493-497
Author(s):  
Dong Chen ◽  
Hua Pei Wang ◽  
Qing Guo

To meet the demand for high precision measurements of radar cross section (RCS) in microwave anechoic chamber, the effect of angle repeatability of position servo system in background cancellation technology is analyzed and its error mathematical model is presented. Then a method of high speed synchronization angle measurement based on CPLD is proposed, which improves the precision of synchronization angle measurement in any fixed angle interval. The experiment results show that this method can effectively solve the accuracy of target RCS when rotating.


Sign in / Sign up

Export Citation Format

Share Document