Voltage Profile Estimation using State Estimation in a Distribution Network

2021 ◽  
Vol 141 (6) ◽  
pp. 440-447
Author(s):  
Riku Akasaka ◽  
Ryoichi Hara ◽  
Hiroyuki Kita ◽  
Takayuki Tanabe ◽  
Syuhei Sugimura
2015 ◽  
Vol 775 ◽  
pp. 409-414
Author(s):  
Bing Jun Li ◽  
Su Quan Zhou ◽  
Xiao Xiang Lun

It is of great importance to identify the location of the harmonic sources for the harmonic governance in the power system. Applied with optimal measurement placement (OMP) and harmonic state estimation (HSE), this paper presents a novel process based on PMU measurements to locate the harmonic sources in the distribution network. Considering the cost and the observability, the OMP can provide a scheme of the measurement placement with the minimum number of PMU measurements. In order to simplify the HSE equation, the measured data are converted to the form of voltage by the method proposed in this paper.By solving the HSE equation, the location and magnitude of the harmonic source are evaluated. The methodology is applied to the IEEE 33-bus system, and the obtained results are properly analyzed.


2021 ◽  
Vol 3 (5) ◽  
Author(s):  
Arvind Sharma ◽  
Mohan Kolhe ◽  
Alkistis Kontou ◽  
Dimitrios Lagos ◽  
Panos Kotsampopoulos

Abstract In this paper, solar photovoltaic hosting capacity within the electrical distribution network is estimated for different buses, and the impacts of high PV penetration are evaluated using power hardware-in-loop testing methods. It is observed that the considered operational constraints (i.e. voltage and loadings) and their operational limits have a significant impact on the hosting capacity results. However, with increasing photovoltaic penetration, some of the network buses reach maximum hosting capacity, which affects the network operation (e.g. bus voltages, line loading). The results show that even distributing the maximum hosting capacity among different buses can increase the bus voltage rise to 9%. To maintain the network bus voltages within acceptable limits, reactive power voltage-based droop control is implemented in the photovoltaic conditioning devices to test the dynamics of the network operation. The results show that implementation of the droop control technique can reduce the maximum voltage rise from 9% to 4% in the considered case. This paper also presents the impact of forming a mesh type network (i.e. from radial network) on the voltage profile during PV penetration, and a comparative analysis of the operational performance of a mesh type and radial type electrical network is performed. It is observed that the cumulative effect of forming a mesh type network along with a droop control strategy can further improve the voltage profile and contribute to increase photovoltaic penetration. The results are verified using an experimental setup of digital real-time simulator and power hardware-in-loop test methods. The results from this work will be useful for estimating the appropriate photovoltaic hosting capacity within a distribution network and implementation of a droop control strategy in power conditioning devices to maintain the network operational parameters within the specified limits. Highlights Voltage and line loading constraints’ combination can reduce PV hosting capacity by 50% as compared to only voltage as a constraint. Implementation of reactive power versus voltage droop control in PV power conditioning device can reduce voltage variation from 9% to 4%. In a PV integrated electrical energy network, line loading can be reduced by 20% if the network is configured from radial to mesh type.


Sign in / Sign up

Export Citation Format

Share Document