scholarly journals Automatizáltan mérhető biomarkerek az akut myocardialis infarctus diagnosztikájában

2015 ◽  
Vol 156 (24) ◽  
pp. 964-971
Author(s):  
Ferenc Kovács ◽  
Ibolya Kocsis ◽  
Marina Varga ◽  
Enikő Sárváry ◽  
György Bicsák

Introduction: Cardiac biomarkers have a prominent role in the diagnosis of acute myocardial infarction. Aim: The aim of the authors was to study the diagnostic effectiveness of automated measurement of cardiac biomarkers. Method: Myeloperoxidase, high-sensitivity C-reactive protein, myoglobin, heart-type fatty acid binding protein, creatine kinase, creatine kinase MB, high-sensitivity troponin I and T were measured. Results: The high-sensitivity troponin I was the most effective (area under curve: 0.86; 95% confidence interval: 0.77–0.95; p<0.001) for the diagnosis of acute myocardial infarction. Considering a critical value of 0.35 ng/mL, its sensitivity and specificity were 81%, and 74%, respectively. Combined evaluation of the high-sensitivity troponin T and I, chest pain, and the electrocardiogram gave the best results for separation of acute myocardial infarction from other diseases (correct classification in 62.5% and 98.9% of patients, respectively). Conclusions: Until a more sensitive and specific cardiac biomarker becomes available, the best method for the diagnosis of acute myocardial infarction is to evaluate electrocardiogram and biomarker concentration and to repeat them after 3–6 hours. Orv. Hetil., 2015, 156(24), 964–971.

2011 ◽  
Vol 152 (38) ◽  
pp. 1528-1534 ◽  
Author(s):  
Eszter Szánthó ◽  
Zoltán Szabó ◽  
József Varga ◽  
György Paragh ◽  
Anna V. Oláh

Troponin is the first choice in the diagnosis of acute myocardial infarction. Correct interpretation is challenging, because high sensitive troponin tests used today detect even the smallest cardiac damage. Methods: High sensitive troponin T (Roche) and troponin I (Mitsubishi Pathfast) and creatine-kinase activity were measured in 20 patients, each having two samples with the time lapse 3–9 hours. Results: In the group without acute myocardial infarction (n = 10) no significant increase in creatine-kinase and creatine-kinase-MB levels were seen, and the mild raise of troponins was due to other cardiovascular problems (atrial fibrillation, paroxysmal supraventricular tachycardia). With acute myocardial infarction (n = 10) a dramatic increase of troponin levels was found in the second samples, and also an increase of creatine-kinase and creatine-kinase-MB activity. According to Fischer-probe a twofold or higher increase of troponin implies 19-times higher risk of acute myocardial infarction in the case of troponin T and 8-times odds ratio at troponin I. Conclusions: The patient’s accompanying diseases should always be considered. If the troponin level is elevated, the measurement should be repeated within 3–6 hours. When troponin shows at least a twofold increase and the patient has chest pain or positive ECG, AMI is likely, and the patient needs special medical care. Although the first troponin level might be elevated if accompanying diseases cause chronic cardiac damage, it can be differentiated by a second troponin measurement. Orv. Hetil., 2011, 152, 1528–1534.


1995 ◽  
Vol 41 (9) ◽  
pp. 1266-1272 ◽  
Author(s):  
J Mair ◽  
D Morandell ◽  
N Genser ◽  
P Lechleitner ◽  
F Dienstl ◽  
...  

Abstract Early sensitivities of creatine kinase (CK), CKMB (activity and mass), CKMM and CKMB isoform ratios, myoglobin, cardiac troponin I (cTnI), and cardiac troponin T (cTnT) were compared to find the most sensitive serum marker for acute myocardial infarction (AMI) during the first hours after onset of chest pain. In a prospective study we investigated 37 consecutive patients with AMI who were admitted to the coronary care unit within 4 h after onset of chest pain. Blood samples were drawn every hour for the first 10 h after admission. CKMB mass concentrations, CKMM and CKMB isoform ratios, myoglobin, cTnI, and cTnT increased significantly (P &lt; or = 0.0067) earlier than CK and CKMB activity and were also significantly (P &lt; or = 0.046) and markedly more sensitive on admission. Differences in early sensitivities of myoglobin, CKMB mass, CK isoform ratios, cTnI, and cTnT were small and not significant. Therefore, turnaround time and practicality for emergency determination of methods, specificities of markers, the required specificity in the individual patient, and costs mainly determine the choice among myoglobin, CKMB mass, CK isoforms, cTnI, and cTnT.


Circulation ◽  
2007 ◽  
Vol 116 (suppl_16) ◽  
Author(s):  
Stanley Chia ◽  
O. Christopher Raffel ◽  
Faisal Merchant ◽  
Frans J Wackers ◽  
Fred Senatore ◽  
...  

Background: Assessment of cardiac biomarker release has been traditionally used to estimate the size of myocardial damage after acute myocardial infarction (AMI). However, the significance of cardiac biomarkers in the setting of primary percutaneous coronary intervention (PCI) has not been systematically studied in a large patient cohort. We evaluated the usefulness of serial and single time-point measures of various cardiac biomarkers (creatine kinase (CK), CK-MB, troponin T and I) in predicting infarct size and left ventricular ejection fraction (LVEF) after primary PCI. Methods: EVOLVE (Evaluation of MCC-135 for Left Ventricular Salvage in AMI) was a randomized double-blind, placebo-controlled trial comparing the efficacy of intracellular calcium modulator as an adjunct to primary PCI in patients with first large AMI. Levels of cardiac biomarkers (CK, CK-MB mass, troponin T and I) were determined in 375 patients at baseline before PCI and 2, 4, 12, 24, 48 and 72 hours thereafter. Single photon emission computed tomography imaging was performed to measure infarct size and LVEF on day 5. Results: Area under curve and peak concentrations of all cardiac markers: CK, CK-MB mass, troponin T and troponin I were significantly correlated with myocardial infarct size and LVEF determined on day 5 (Spearman correlation, all P< 0.001; Table ). Troponin I, however provided the best predictor and a single measure at 72 hr was a strong indicator of both infarct size and LVEF. Using receiver operator characteristics curve, troponin I cutoff value of >55 pg/mL at 72 hr has 90% sensitivity and 70% specificity for detection of large infarct size≥10% ( c =0.88; P< 0.001). Conclusions: Plasma levels of CK, CK-MB, troponin T and troponin I remain useful predictors of infarct size and cardiac function in the era of primary PCI for AMI. A single measurement of circulating troponin I at 72 hours can provide an effective and convenient indicator of infarct size and LVEF in clinical practice. Correlation of cardiac biomarkers with Day 5 SPECT determined infarct size and LVEF


1994 ◽  
Vol 40 (7) ◽  
pp. 1291-1295 ◽  
Author(s):  
J E Adams ◽  
K B Schechtman ◽  
Y Landt ◽  
J H Ladenson ◽  
A S Jaffe

Abstract Although measurement of cardiac troponin I (cTnI) is, in some situations, more specific for detection of cardiac injury than is measurement of the MB isoenzyme of creatine kinase (MBCK), its sensitivity and specificity relative to MBCK for detection of myocardial infarction has not been established. Accordingly, we studied prospectively 199 consecutive patients admitted to the coronary care unit. Values of MBCK and cTnI mass were determined in all samples. Of the 188 patients admitted with a suspicion of acute myocardial ischemia, 89 were diagnosed as having an acute myocardial infarction on the basis of the patterns of MBCK values. Eighty-six of these patients also had increased cTnI (concordance, 96.6%); three did not. Of the patients diagnosed as without infarction, five with unstable angina and symptoms in the day(s) prior to admission had increased cTnI, for a cTnI specificity of 94.9%. Receiver operating characteristic curve analysis indicated that cTnI and MBCK had statistically indistinguishable diagnostic accuracies for the detection of acute myocardial infarction.


2020 ◽  
Vol 9 (3) ◽  
pp. 775 ◽  
Author(s):  
Christian Frédéric Zachoval ◽  
Ramona Dolscheid-Pommerich ◽  
Ingo Graeff ◽  
Bernd Goldschmidt ◽  
Andreas Grigull ◽  
...  

It remains unclear how introduction of high-sensitivity troponin T testing, as opposed to conventional troponin testing, has affected the diagnosis of acute myocardial infarction (AMI) and resource utilization in unselected hospitalized patients. In this retrospective analysis, we include all consecutive cases from our center during two corresponding time frames (10/2016–04/2017 and 10/2017–04/2018) for which different troponin tests were performed: conventional troponin I (cTnI) and high-sensitivity troponin T (hs-TnT) assays. Testing was performed in 18,025 cases. The incidence of troponin levels above the 99th percentile was significantly higher in cases tested using hs-TnT. This was not associated with increased utilization of echocardiography, coronary angiography, or percutaneous coronary intervention. Although there were no changes in local standard operating procedures, study site personnel, or national coding guidelines, the number of coded AMI significantly decreased after introduction of hs-TnT. In this single-center retrospective study comprising 18,025 mixed medical and surgical cases with troponin testing, the introduction of hs-TnT was not associated with changes in resource utilization among the general cohort, but instead, led to a decrease in the international classification of diseases (ICD)-10 coded diagnosis of AMI.


1997 ◽  
Vol 134 (4) ◽  
pp. 622-630 ◽  
Author(s):  
Milenko J. Tanasijevic ◽  
Christopher P. Cannon ◽  
Donald R. Wybenga ◽  
George A. Fischer ◽  
Christine Grudzien ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document