scholarly journals Cost-Effectiveness Analysis of High-Sensitivity Troponin T Versus Conventional Troponin I Testing for Acute Myocardial Infarction

2018 ◽  
Vol 21 ◽  
pp. S160-S161
Author(s):  
W Hsu ◽  
B Galm ◽  
S Hsu ◽  
C Lee
2020 ◽  
Vol 9 (3) ◽  
pp. 775 ◽  
Author(s):  
Christian Frédéric Zachoval ◽  
Ramona Dolscheid-Pommerich ◽  
Ingo Graeff ◽  
Bernd Goldschmidt ◽  
Andreas Grigull ◽  
...  

It remains unclear how introduction of high-sensitivity troponin T testing, as opposed to conventional troponin testing, has affected the diagnosis of acute myocardial infarction (AMI) and resource utilization in unselected hospitalized patients. In this retrospective analysis, we include all consecutive cases from our center during two corresponding time frames (10/2016–04/2017 and 10/2017–04/2018) for which different troponin tests were performed: conventional troponin I (cTnI) and high-sensitivity troponin T (hs-TnT) assays. Testing was performed in 18,025 cases. The incidence of troponin levels above the 99th percentile was significantly higher in cases tested using hs-TnT. This was not associated with increased utilization of echocardiography, coronary angiography, or percutaneous coronary intervention. Although there were no changes in local standard operating procedures, study site personnel, or national coding guidelines, the number of coded AMI significantly decreased after introduction of hs-TnT. In this single-center retrospective study comprising 18,025 mixed medical and surgical cases with troponin testing, the introduction of hs-TnT was not associated with changes in resource utilization among the general cohort, but instead, led to a decrease in the international classification of diseases (ICD)-10 coded diagnosis of AMI.


2020 ◽  
pp. 204887262092419
Author(s):  
Nils Arne Sörensen ◽  
Johannes Tobias Neumann ◽  
Francisco Ojeda ◽  
Thomas Renné ◽  
Mahir Karakas ◽  
...  

Background Most studies assessing the diagnostic value of high-sensitivity troponin in the diagnosis of myocardial infarction used batch-wise analyses of frozen samples for high-sensitivity troponin measurements. Whether the accuracy of these batch-wise high-sensitivity troponin measurements described in diagnostic studies is comparable to clinical routine is unknown. Methods We enrolled 937 patients presenting with suspected myocardial infarction in this prospective cohort study. Measurements of high-sensitivity troponin I (Abbott Architect) and high-sensitivity troponin T (Roche) were performed in two settings: (a) on-demand in clinical routine using fresh blood samples; and (b) in batches using frozen blood samples from the same individuals at three timepoints (0 hours, 1 hour and 3 hours after presentation). Results Median troponin levels were not different between on-demand and batch-wise measurements. Troponin levels in the range of 0 to 40 ng/L showed a very high correlation between the on-demand and batch setting (Pearson correlation coefficient ( r) was 0.92–0.95 for high-sensitivity troponin I and 0.96 for high-sensitivity troponin T). However, at very low troponin levels (0 to 10 ng/L) correlation between the two settings was moderate ( r for high-sensitivity troponin I 0.59–0.66 and 0.65–0.69 for high-sensitivity troponin T). Application of guideline-recommended rapid diagnostic algorithms showed similar diagnostic performance with both methods. Conclusions Overall on-demand and batch-wise measurements of high-sensitivity troponin provided similar results, but their correlation was moderate, when focusing on very low troponin levels. The application of rapid diagnostic algorithms was safe in both settings. Trial Registration: www.clinicaltrials.gov (NCT02355457)


CJEM ◽  
2018 ◽  
Vol 20 (S1) ◽  
pp. S28-S28
Author(s):  
A. D. McRae ◽  
S. Vatanpour ◽  
J. Ji ◽  
H. Yang ◽  
D. Southern ◽  
...  

Introduction: Patients with chronic kidney disease (CKD) are at high risk of cardiovascular events, and have worse outcomes following acute myocardial infarction (AMI). Cardiac troponin is often elevated in CKD, making the diagnosis of AMI challenging in this population. We sought to quantify test characteristics for AMI of a high-sensitivity troponin T (hsTnT) assay performed at emergency department (ED) arrival in CKD patients with chest pain, and to derive rule-out cutoffs specific to patient subgroups stratified by estimated glomerular filtration rate (eGFR). We also quantified the sensitivity and classification performance of the assays limit of detection (5 ng/L) and the FDA-approved limit of quantitation (6 ng/L) for ruling out AMI at ED arrival. Methods: Consecutive patients in four urban EDs from the 2013 calendar year with suspected cardiac chest pain who had a Roche Elecsys hsTnT assay performed on arrival were included f. This analysis was restricted to patients with an eGFR< 60 ml/min/1.73m2. The primary outcome was 7-day AMI. Secondary outcomes included major adverse cardiac events (death, AMI and revascularization). Test characteristics were calculated and ROC curves were generated for eGFR subgroups. Results: 1416 patients were included. 7-day AMI incidence was 10.1%. 73% of patients had an initial hsTnT concentration greater than the assays 99th percentile (14 ng/L). TCurrently accepted cutoffs to rule out MI at ED arrival ( 5 ng/L and 6 ng/L) had 100% sensitivity for AMI, but no patients with an eGFR less than 30 ml/min/1.73M had hsTnT concentrations below these thresholds. We derived eGFR-adjusted cutoffs to rule out MI with sensitivity >98% at ED arrival, which were able to rule out 6-42% of patients, depending on eGFR category. The proportion of patients able to be accurately ruled-in with a single hsTnT assay was substantially lower among patients with an eGFR <30 ml/min/1.73m2 (6-20% vs 25-43%). We also derived eGFR-adjusted cutoffs to rule-in AMI with specificity >90%, which accurately ruled-in up to 18% of patients. Conclusion: Cutoffs achieving acceptable diagnostic performance for AMI using single hsTnT sampling on ED arrival may have limited clinical utility, particularly among patients with very low eGFR. The ideal diagnostic strategy for AMI in patients with CKD likely involves serial high-sensitivity troponin testing with diagnostic thresholds customized to different eGFR categories.


2015 ◽  
Vol 156 (24) ◽  
pp. 964-971
Author(s):  
Ferenc Kovács ◽  
Ibolya Kocsis ◽  
Marina Varga ◽  
Enikő Sárváry ◽  
György Bicsák

Introduction: Cardiac biomarkers have a prominent role in the diagnosis of acute myocardial infarction. Aim: The aim of the authors was to study the diagnostic effectiveness of automated measurement of cardiac biomarkers. Method: Myeloperoxidase, high-sensitivity C-reactive protein, myoglobin, heart-type fatty acid binding protein, creatine kinase, creatine kinase MB, high-sensitivity troponin I and T were measured. Results: The high-sensitivity troponin I was the most effective (area under curve: 0.86; 95% confidence interval: 0.77–0.95; p<0.001) for the diagnosis of acute myocardial infarction. Considering a critical value of 0.35 ng/mL, its sensitivity and specificity were 81%, and 74%, respectively. Combined evaluation of the high-sensitivity troponin T and I, chest pain, and the electrocardiogram gave the best results for separation of acute myocardial infarction from other diseases (correct classification in 62.5% and 98.9% of patients, respectively). Conclusions: Until a more sensitive and specific cardiac biomarker becomes available, the best method for the diagnosis of acute myocardial infarction is to evaluate electrocardiogram and biomarker concentration and to repeat them after 3–6 hours. Orv. Hetil., 2015, 156(24), 964–971.


2016 ◽  
Vol 23 (9) ◽  
pp. 1004-1013 ◽  
Author(s):  
Richard Body ◽  
Christian Mueller ◽  
Evangelos Giannitsis ◽  
Michael Christ ◽  
Jorge Ordonez-Llanos ◽  
...  

CJEM ◽  
2018 ◽  
Vol 20 (S1) ◽  
pp. S26-S27
Author(s):  
J. E. Andruchow ◽  
T. S. Boyne ◽  
S. Vatanpour ◽  
D. Wang ◽  
A. D. McRae

Introduction: Chest pain is one of the most common presenting complaints to emergency departments (EDs) across the world, and the exclusion of acute myocardial infarction (AMI) using troponin testing is central to the care of many of these patients. While testing strategies using conventional troponin assays require repeat testing over many hours to avoid missed diagnoses, high-sensitivity troponin (hs-cTn) assays may be able to exclude AMI in a large proportion of patients with a single result at presentation. This objective of this study is to validate the ability of very low concentrations of hs-cTn at presentation to exclude AMI in ED chest pain patients. Methods: This prospective cohort study was conducted at a single urban tertiary center and regional percutaneous coronary intervention site in Calgary, Alberta. Patients were eligible for enrolment if they presented to the ED with chest pain, were 25-years or older and required biomarker testing to rule out AMI at the discretion of the attending emergency physician. Patients were excluded if they had clear acute ischemic ECG changes, new arrhythmia or renal failure requiring hemodialysis. A high-sensitivity troponin result (Roche Elecsys hs-cTnT) was obtained in all patients at presentation. The primary outcome was AMI on the index visit. Secondary outcomes included 30-day AMI and major adverse cardiac events (MACE - including AMI, revascularization or cardiac death). Electronic medical records were reviewed and telephone follow-up was obtained for all patients at 30-days to ensure relevant events were captured. Two physician adjudication (board-certified emergency physician and cardiologist) was obtained for all outcomes. This study was REB approved. Results: A total of 1,167 patients were enrolled from August 2014 September 2016, of which 191 (16.3%) patients had an initial troponin below the limit of blank (LoB, <3 ng/L) and 416 (32.8%) were below the limit of detection (LoD, <5 ng/L). The sensitivity of a single troponin below the LoB (<3 ng/L) for index AMI was 100% (95% CI 96.2%-100%) and for 30-day AMI was 100% (95% CI 96.4-100%). The sensitivity of a troponin below the LoD (<5 ng/L) for index AMI was 97.9% (95% CI 92.7%-99.8%) and for 30-day AMI was 98.0% (95% CI 93.0-99.8%). Sensitivity for 30-day MACE at both cutoffs was lower: 98.4% (95% CI 94.3-99.8%) for <3 ng/L, and 94.4% (95% CI 88.8-97.7%) for <5 ng/L, respectively; however, negative predictive values remained high at both cutoffs: <3 ng/L, 99.0% (95% CI 96.3-99.9%) and <5 ng/L, 98.3% (95% CI 96.6-99.3%). Conclusion: A high sensitivity troponin T result below the LoB (<3 ng/L) is highly sensitive for excluding AMI and identifies patients at low risk of 30-day MACE. A result below the LoB (<5 ng/L) will identify a larger population of patients as low risk but has a greater risk of missed AMI and MACE.


Sign in / Sign up

Export Citation Format

Share Document