scholarly journals Penggunaan gigitiruan sebagian lepasan kerangka logam pascaperawatan periodontal Using metal frame removable partial denture after periodontal treatment

2011 ◽  
Vol 10 (2) ◽  
pp. 97 ◽  
Author(s):  
Krisnadi Setiawan ◽  
Aprillia Adenan

Metal framework denture is needed in patient with tooth loss accompanied by the presence of periodontal disease inthe remaining tooth is needed. This denture primarily maintains the existing teeth post periodontal treatment. Theuse of metal framework in this case can help to prevent tooth movement and maintain tooth position afterperiodontal treatment. Therefore, the success of the treatment can be achieved because the metal characteristic ismore rigid when compared to other dental materials. This paper discusses the use of frame denture in patient afterperiodontal treatment on the remaining teeth in lower arch. It can be concluded that removable denture with metalframe combined with splint must be done on mobile teeth, to decrease mobile teeth and to preventincreasing of periodontal tissue damage after periodontal treatment.

2017 ◽  
Vol 52 (4) ◽  
pp. 270
Author(s):  
Okti Setyowati ◽  
Endang Kusdarjanti

The making of removable denture is performed by a dental laboratory. To facilitate the identification, according to Kennedy classification, classes are divided onto groups, the Kennedy class I, II, III and IV. To suit with the needs of the dental laboratory tasks commonly done, priority are necessary for common cases and should to be taught to students of Dental Health Technology Diploma. In Surabaya, research of various cases of removable partial denture with the various Kennedy classifications has never been done before. This study was to analyze the pattern of service for the removable partial denture manufacture in dental laboratory at Surabaya (2011 – 2013). The research is an observatory analytic. The population is all dental laboratories located around the campus of the Faculty of Dentistry Airlangga University Surabaya. The sample was the whole population is willing to become respondents. Sampling by total sampling. The method of collecting data using secondary data from a dental laboratory in Surabaya from 2011 until 2013. The note is cases removable denture according to the classification of Kennedy that Kennedy Class I, II, III and IV. Also of note kinds of materials used to make the denture base that is heat cured acrylic resins, thermoplastic resins and metals coherent. The data is a compilation table charting the frequency until needed, then analyzed using cross tabulation. Mostly denture type is flexible type and the least is metal framework. Most cases by classification Kennedy is followed by class II class III and class II and more recently is the fourth. In conclusion, in 2011 and 2013 the manufacture of removable partial dentures according to the classification of Kennedy Class III is the most common in both the upper arch and lower jaw, followed by Class II, Class I and Class IV. In 2012 which is the highest grade III followed by class II, class IV and class I. The denture type most used is a flexible denture, followed acrylic denture and the last is the metal framework.


2013 ◽  
Vol 3 (2) ◽  
pp. 60
Author(s):  
NB Jamayet ◽  
U Habiba ◽  
SZE Zai ◽  
S Hossain

Background: Distal extension edentulism can affect the patient’s ability to function as a dentate person. A well-made removable partial denture that has appropriate extensions, borders and ridge-to-dentition relationship will benefit the partially edentulous patient by providing increased comfort and improved dental function. This article described a patient who had a bilateral distal extension removable partial denture in both upper and lower arch. The prosthesis showed a successful rehabilitation with proper function and aesthetics. Methods: A Kennedy class I bilateral free end saddle edentulous arch in both upper and lower arch was rehabilitated with removable cast partial denture. The case had the reasonable amount of crown: root ratio for the remaining abutment teeth for placement of metal framework, occlusal rest and cast clasp. Results: The delivered denture showed proper sitting of occlusal rest and cast clasp. Retention and stability was acceptable. Occlusion had achieved its desired occlusion scheme. Conclusion: Removable cast partial denture is a suitable option for the rehabilitation of partially edentulous case if the case has such amount of abutment teeth remaining with healthy periodontal condition. DOI: http://dx.doi.org/10.3329/bjdre.v3i2.16616 Bangladesh Journal of Dental Research & Education Vol.3(2) 2013: 60


Author(s):  
J. Taczała ◽  
J. Sawicki

Purpose: The purpose of this paper is to analyse attempts at improving the bond between acrylic artificial teeth and the denture base plate - considered in the context of single incisors in framework denture. Design/methodology/approach: It is a review article focusing on the analysis of state of the art in the field of the bond between the polymerised acrylic (teeth) and the polymerising acrylic resin during the production of denture (denture plate). Previous works regard the issue of individual incisor teeth (both upper and lower) breaking off from the metal partial denture. Findings: The bond between artificial acrylic teeth and the acrylic denture plate of the prosthesis was discussed. Ways of improving this bond were also presented. Although researchers and companies offer many methods for improving this bond, none of them refer directly to the issue discussed in this article. In conclusion- the hitherto scientific achievements work well in the case of acrylic prostheses without a metal frame, which constitutes an obstacle for achieving the effect required. In this work, it is suggested that further research would not only develop and provide more detail on the issue of the bond between artificial teeth and the denture plate, but also solve the problem appearing in cases of metal partial denture. Originality/value: This article shows a significant problem that hasn’t been discussed in detail in the past.


2013 ◽  
Vol 12 (2) ◽  
pp. 123
Author(s):  
Sri W. Rais ◽  
Setyawan Bonifacius

In making removable denture, some aspects must be considered: retention, stabilization, support, comfort, andaesthetic. Retention plays an important role in the success of a removable denture. Retention can be obtained from theundercut area, or friction of the denture’s components to the abutment or abutment. Clasp as a retainer, both of metalcasting and wire have been frequently used in the removable partial denture. The clasp has some shortcomings in itsusing, namely color of the metal can sometimes interfere with the aesthetic of the wearer and cannot be placed on teeththat have experienced extensive caries. Telescopic crown as retainer has several advantages, which can be used oncrown of abutment that has experienced extensive caries or tooth that will be an abutment but have endodontic-treated.On telescopic crowns, retention is obtained from the friction between the primary crowns against secondary crown thatserves as a retainer. This case report describes two cases of a removable denture with a metal framework using atelescopic crown on one tooth that serves as a retainer in the case of one-side free-end edentulous.


2013 ◽  
Vol 12 (2) ◽  
pp. 118
Author(s):  
Irene Melina ◽  
Soekobagiono Soekobagiono ◽  
Harry Laksono

In the case of losing many teeth and the residual teeth have short clinical crown, design of the denture may hybriddenture. Hybrid denture is a removable partial denture with metal frame which have retention in the form ofprecision attachment. In short clinical crown, placement of crowns and the use of traction can be a problem,because there is no or lack of retention. In the manufacture of hybrid denture with precision attachment retention,using abutment with short clinical crowns is contraindicated. But in some literatures mentioned that the rest of theclinical crown height of not less than 2 mm can still be used as an abutment, but the abutments must be modified,such as making a longer preparation towards cervical edge. In several studies and literature, it is mentioned that toimprove the retention of the crown, the axial wall of abutment must be 4-6°. This article is aimed to report the clinical success of using the hybrid denture on abutment teeth which have short clinical crowns in a patient woman


Author(s):  
Joana Cabrita ◽  
◽  
Teresa Mendes ◽  
João Martins ◽  
Luís Lopes ◽  
...  

The selective laser melting technology is an additive digital method that permits producing metal frameworks for removable partial dentures. The existing literature has compared this technique with the classic technique in terms of precision, quality of fit, and function. This work describes a clinical case of a metal framework produced by the selective laser melting technique in a patient rehabilitated with a removable partial denture. No adjustments were required when the metal framework was inserted, showing good adaptation and stability to the abutment teeth and surrounding tissues. Further studies are necessary for a significant assessment of this technique’s clinical applicability.


Sign in / Sign up

Export Citation Format

Share Document