Determination of Vanadium Valency in Roasted Stone Coal by Separate Dissolve-Potentiometric Titration Method

2012 ◽  
Vol 1380 ◽  
Author(s):  
Bao Shenxu ◽  
Zhang Yimin ◽  
Hang Jing ◽  
Yang Xiao ◽  
Hu Yangjia

ABSTRACTStone coal is an important vanadium-bearing resource in China. Most vanadium exists in stone coal as V(III), which is stable and not easily to be extracted. The V(III) should be oxidized to V(IV) and/or V(V) by roasting with additives at high temperature and then extracted by acid leaching and/or water leaching. Hence, the vanadium valency in roasted stone coal can reflect the roasting efficiency and leaching rate. In traditional digestion process, the V(V) can oxidize V(III) in solution and this causes great error to the determination of vanadium valency. In this study, the V(IV) and V(V) in roasted stone coal is dissolved firstly in 5% of hydrochloric acid at room temperature for 1h because the V(III) embedded in crystal lattice can not dissolve in dilute acid. The acid solution containing V(IV) and V(V) is titrated by 0.02 M ammonium ferrous sulfate (AFS), and the jump in titration curve indicates the reducing of V(V) to V(IV) by ferrous ion. The volume of V(V) can be calculated according to the consumption of AFS. The total volume of vanadium can be determined by potassium permanganate oxidation-ammonium ferrous sulfate titrimetric method. Hence, the volume of V(IV) can be obtained by deducting the quantity of V(V) from the total vanadium. Secondly, the undissolved residue is digested in Teflon vessel by phosphoric acid and hydrofluoric acid at 90 °C for 2h. The digestion solution is also titrated by AFS under nitrogen atmosphere, and the jump in titration curve denotes the reducing of V(IV) to V(III) by ferrous ion in phosphoric acid medium. So, the volume of V(III) and V(IV) can be obtained in the same way. This method is characterized by high measuring accuracy and excellent reproducibility.

2011 ◽  
Vol 396-398 ◽  
pp. 620-623
Author(s):  
Ya Li Zhang ◽  
Xian Jin Yu ◽  
Xiao Na Guo ◽  
Xiao Bin Li

In this work, it was aimed to select and propose a feasible as well as an applicable method, or series of methods for the extraction of zinc. After determination of the components of the residue, water leaching, acid leaching and roasting-leaching were performed to reclaim Zn. Roasting-leaching was found to be effectively for Zn extraction by controlling acid mass, roasting duration and temperature as parameters. At the optimum conditions, 0.7 times the amount of H2SO4 at 250 °C for 150 min in roasting, 82.05% of initial Zn content was extracted.


2012 ◽  
Vol 117-118 ◽  
pp. 108-115 ◽  
Author(s):  
Puhong Ye ◽  
Xuewen Wang ◽  
Mingyu Wang ◽  
Yeye Fan ◽  
Xiaoyan Xiang

1976 ◽  
Vol 37 (C6) ◽  
pp. C6-739-C6-743 ◽  
Author(s):  
P. A. FLINN ◽  
B. J. ZABRANSKY ◽  
S. L. RUBY
Keyword(s):  

1963 ◽  
Vol 44 (1) ◽  
pp. 47-66 ◽  
Author(s):  
W. Nocke ◽  
H. Breuer

ABSTRACT A method for the chemical determination of 16-epi-oestriol in the urine of nonpregnant women with a qualitative sensitivity of less than 0.5 μg/24 h is described. The separation of 16-epi-oestriol and oestriol is accomplished by converting 16-epi-oestriol into its acetonide, a reaction which is stereoselective for cis-glycols and therefore not undergone by oestriol as a trans-glycol. Following partition between chloroform and aqueous alkali, the acetonide of 16-epi-oestriol is completely separated with the organic layer whereas oestriol as a strong phenol remains in the alkaline phase. 16-epi-oestriol is chromatographed on alumina as the acetonide and determined as a Kober chromogen. This procedure can easily be incorporated into the method of Brown et al. (1957 b) thus making possible the simultaneous routine assay of oestradiol-17β, oestrone, oestriol and 16-epi-oestriol from one sample of urine. The specificity of the method was established by separation of 16-epi-oestriol from nonpregnancy urine as the acetonide, hydrolysis of the acetonide by phosphoric acid, isolation of the free compound by microsublimation and identification by micro melting point, colour reactions and chromatography. The accuracy of the method is given by a mean recovery of 64% for pure crystalline 16-epi-oestriol when added to hydrolysed urine in 5–10 μg amounts. The precision is given by s = 0.24 μg/24 h. For the duplicate determination of 16-epi-oestriol the qualitative sensitivity is 0.44 μg/24 h, the maximum percentage error being ± 100% The quantitative sensitivity (±25% error) is 1.7 μg/24 h.


1992 ◽  
Vol 57 (7) ◽  
pp. 1393-1404 ◽  
Author(s):  
Ladislav Svoboda ◽  
Jan Uhlíř ◽  
Zdeněk Uhlíř

The properties of Ostsorb DETA, a selective ion exchanger based on modified bead cellulose with chemically bonded diethylenetriamine functional groups, were studied, and its applicability to the preconcentration of trace amounts of lead from aqueous solutions was verified. The conditions of the preconcentration procedure in the column and batch modes were optimized for this purpose. The results obtained were applied to the determination of lead in phosphoric acid.


Sign in / Sign up

Export Citation Format

Share Document