scholarly journals LV SIDE DISTRIBUTED POWER FACTOR CORRECTION SYSTEM

2014 ◽  
Vol 03 (09) ◽  
pp. 217-221
Author(s):  
Santosh K. Verma .
Author(s):  
Kartikesh Kumar Jha ◽  
Bidyut Mahato ◽  
Prem Prakash ◽  
Kartick Chandra Jana

Rapid increase of consumers in electronics devices and the use of mains rectification circuits inside these electronic devices is the root cause of mains harmonic distortion. Automatic power factor correction techniques can be applied to the industries, power systems and households to make them stable inturns increases the efficiency of system as well as the apparatus. This paper deals with the hardware design of active power factor correction circuit employing boost converter which is used to boost the DC voltages with a controller based on PID control strategy. The pulses given to power switches by pulse width modulation techniques generated by utilizing micro-controller board, Arduino thus obviating the need of complex hardware circuitry. MATLAB/SIMULINK was used to design and tune the PID controller parameters. The simulation results are matching with the predictions and the same was implemented as hardware. The waveforms various test points and across capacitors were obtained, studied and compared with the theoretical waveforms and are found to be in precise proximity of theoretical waveforms.


2000 ◽  
Vol 15 (3) ◽  
pp. 529-535 ◽  
Author(s):  
E. Dallago ◽  
M. Passoni ◽  
G. Sassone ◽  
G. Venchi

2021 ◽  
Vol 11 (10) ◽  
pp. 4322
Author(s):  
Martina Kutija ◽  
Luka Pravica

This paper presents a case study of three-phase ferroresonance in a low-voltage power factor correction system and investigates the influence of harmonic distortion on the occurrence of ferroresonance. Ferroresonance is an extremely dangerous and rare phenomenon that causes overvoltages and overcurrents in the system and degrades the power quality. The study is carried out on real field measurements in an industrial plant where ferroresonance occurs in the power factor correction (PFC) system at the detuned reactor. The three-phase ferroresonance analysed in this paper is an extremely rare phenomenon that has never been reported in this type of configuration. The measurement results have shown that in this type of configuration the high harmonic distortion is a necessary condition for ferroresonance to occur. In such conditions, switching on the capacitor stage triggers the ferroresonance with quasi-periodic oscillations supported by the medium voltage grid. The main contribution is the analysis of the three-phase ferroresonance in the detuned PFC system and the influence of the harmonics on the occurrence of the ferroresonance in such a case. The possible solutions to this problem and recommendations to avoid this phenomenon are discussed.


Sign in / Sign up

Export Citation Format

Share Document