scholarly journals Preliminary study of the technical limitations of automated breast ultrasound: from procedure to diagnosis

2020 ◽  
Vol 53 (5) ◽  
pp. 293-300 ◽  
Author(s):  
Maria Julia Gregório Calas ◽  
Fernanda Philadelpho Arantes Pereira ◽  
Leticia Pereira Gonçalves ◽  
Flávia Paiva Proença Lobo Lopes

Abstract Objective: To evaluate the main technical limitations of automated breast ultrasound and to determine the proportion of examinations excluded. Materials and Methods: We evaluated 440 automated breast ultrasound examinations performed, over a 12-month period, by technicians using an established protocol. Results: In five cases (1.1%), the examination was deemed unacceptable for diagnostic purposes, those examinations therefore being excluded. Conclusion: Automated breast ultrasound is expected to overcome some of the major limitations of conventional ultrasound in breast cancer screening. In Brazil, this new method can be accepted for inclusion in routine clinical practice only after its advantages have been validated in the national context.

2016 ◽  
Vol 206 (6) ◽  
pp. 1341-1350 ◽  
Author(s):  
Maryellen L. Giger ◽  
Marc F. Inciardi ◽  
Alexandra Edwards ◽  
John Papaioannou ◽  
Karen Drukker ◽  
...  

Author(s):  
Benedikt Schäfgen ◽  
Marija Juskic ◽  
Marcus Radicke ◽  
Madeleine Hertel ◽  
Richard Barr ◽  
...  

Abstract Objective The FUSION-X-US-II prototype was developed to combine 3D automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device. We evaluated the performance of ABUS and tomosynthesis in a single examination in a clinical setting. Methods In this prospective feasibility study, digital breast tomosynthesis and ABUS were performed using the FUSION-X-US-II prototype without any change of the breast position in patients referred for clarification of breast lesions with an indication for tomosynthesis. The tomosynthesis and ABUS images of the prototype were interpreted independently from the clinical standard by a breast diagnostics specialist. Any detected lesion was classified using BI-RADS® scores, and results of the standard clinical routine workup (gold standard) were compared to the result of the separate evaluation of the prototype images. Image quality was rated subjectively and coverage of the breast was measured. Results One hundred one patients received both ABUS and tomosynthesis using the prototype. The duration of the additional ABUS acquisition was 40 to 60 s. Breast coverage by ABUS was approximately 80.0%. ABUS image quality was rated as diagnostically useful in 86 of 101 cases (85.1%). Thirty-three of 34 malignant breast lesions (97.1%) were identified using the prototype. Conclusion The FUSION-X-US-II prototype allows a fast ABUS scan in combination with digital breast tomosynthesis in a single device integrated in the clinical workflow. Malignant breast lesions can be localized accurately with direct correlation of ABUS and tomosynthesis images. The FUSION system shows the potential to improve breast cancer screening in the future after further technical improvements. Key Points • The FUSION-X-US-II prototype allows the combination of automated breast ultrasound and digital breast tomosynthesis in a single device without decompression of the breast. • Image quality and coverage of ABUS are sufficient to accurately detect malignant breast lesions. • If tomosynthesis and ABUS should become part of breast cancer screening, the combination of both techniques in one device could offer practical and logistic advantages. To evaluate a potential benefit of a combination of ABUS and tomosynthesis in screening-like settings, further studies are needed.


2018 ◽  
Vol 16 (11) ◽  
pp. 1362-1389 ◽  
Author(s):  
Therese B. Bevers ◽  
Mark Helvie ◽  
Ermelinda Bonaccio ◽  
Kristine E. Calhoun ◽  
Mary B. Daly ◽  
...  

2018 ◽  
Vol 8 (1) ◽  
Author(s):  
Eun-Kyung Kim ◽  
Hyo-Eun Kim ◽  
Kyunghwa Han ◽  
Bong Joo Kang ◽  
Yu-Mee Sohn ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document