Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breasts: Reader Study of Mammography-Negative and Mammography-Positive Cancers

2016 ◽  
Vol 206 (6) ◽  
pp. 1341-1350 ◽  
Author(s):  
Maryellen L. Giger ◽  
Marc F. Inciardi ◽  
Alexandra Edwards ◽  
John Papaioannou ◽  
Karen Drukker ◽  
...  
2020 ◽  
Vol 53 (5) ◽  
pp. 293-300 ◽  
Author(s):  
Maria Julia Gregório Calas ◽  
Fernanda Philadelpho Arantes Pereira ◽  
Leticia Pereira Gonçalves ◽  
Flávia Paiva Proença Lobo Lopes

Abstract Objective: To evaluate the main technical limitations of automated breast ultrasound and to determine the proportion of examinations excluded. Materials and Methods: We evaluated 440 automated breast ultrasound examinations performed, over a 12-month period, by technicians using an established protocol. Results: In five cases (1.1%), the examination was deemed unacceptable for diagnostic purposes, those examinations therefore being excluded. Conclusion: Automated breast ultrasound is expected to overcome some of the major limitations of conventional ultrasound in breast cancer screening. In Brazil, this new method can be accepted for inclusion in routine clinical practice only after its advantages have been validated in the national context.


Author(s):  
Benedikt Schäfgen ◽  
Marija Juskic ◽  
Marcus Radicke ◽  
Madeleine Hertel ◽  
Richard Barr ◽  
...  

Abstract Objective The FUSION-X-US-II prototype was developed to combine 3D automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device. We evaluated the performance of ABUS and tomosynthesis in a single examination in a clinical setting. Methods In this prospective feasibility study, digital breast tomosynthesis and ABUS were performed using the FUSION-X-US-II prototype without any change of the breast position in patients referred for clarification of breast lesions with an indication for tomosynthesis. The tomosynthesis and ABUS images of the prototype were interpreted independently from the clinical standard by a breast diagnostics specialist. Any detected lesion was classified using BI-RADS® scores, and results of the standard clinical routine workup (gold standard) were compared to the result of the separate evaluation of the prototype images. Image quality was rated subjectively and coverage of the breast was measured. Results One hundred one patients received both ABUS and tomosynthesis using the prototype. The duration of the additional ABUS acquisition was 40 to 60 s. Breast coverage by ABUS was approximately 80.0%. ABUS image quality was rated as diagnostically useful in 86 of 101 cases (85.1%). Thirty-three of 34 malignant breast lesions (97.1%) were identified using the prototype. Conclusion The FUSION-X-US-II prototype allows a fast ABUS scan in combination with digital breast tomosynthesis in a single device integrated in the clinical workflow. Malignant breast lesions can be localized accurately with direct correlation of ABUS and tomosynthesis images. The FUSION system shows the potential to improve breast cancer screening in the future after further technical improvements. Key Points • The FUSION-X-US-II prototype allows the combination of automated breast ultrasound and digital breast tomosynthesis in a single device without decompression of the breast. • Image quality and coverage of ABUS are sufficient to accurately detect malignant breast lesions. • If tomosynthesis and ABUS should become part of breast cancer screening, the combination of both techniques in one device could offer practical and logistic advantages. To evaluate a potential benefit of a combination of ABUS and tomosynthesis in screening-like settings, further studies are needed.


Radiology ◽  
2011 ◽  
Vol 258 (1) ◽  
pp. 106-118 ◽  
Author(s):  
Deborah J. Rhodes ◽  
Carrie B. Hruska ◽  
Stephen W. Phillips ◽  
Dana H. Whaley ◽  
Michael K. O’Connor

2021 ◽  
Vol 39 (15_suppl) ◽  
pp. e13586-e13586
Author(s):  
Richa Bansal ◽  
Bharat Aggarwal ◽  
Lakshmi Krishnan

e13586 Background: Screening mammography is often found to have low sensitivity in women with high density breast tissues. Alternate modalities of breast USG and MRI require high-quality expensive equipment making the regular screening with these modalities less affordable and accessible, particularly in resource-constrained settings This study evaluates the clinical performance of an AI-based test (Thermalytix) that uses machine learning on breast thermal images which could potentially be a low-cost solution for breast screening in low- and middle-income countries (LMICs). Methods: The prospective comparative study conducted from December 2018 to January 2020 evaluated the performance of Thermalytix in women with dense and non-dense breast tissue who presented for a health check-up at a hospital. All women underwent Thermalytix and mammography. Further investigations were recommended for participants who were reported as positive on either test. Sensitivity and specificity of Thermalytix were evaluated across age-groups, menopausal status, and breast densities. Results: Among the 687 women recruited for the study, 459 women who satisfied the inclusion criteria were included in the analysis. 168 women had ACR categories ‘c’ or ‘d’ dense breasts, of which 37 women had an inconclusive mammography report (BI-RADS 0). Overall, 21 women were detected with breast cancer in the study. Thermalytix demonstrated an overall sensitivity of 95.2% (95% CI, 76.1-99·9) and a specificity of 88.6% (95% CI, 85.2-91.4). Among women with dense breast tissue (n=168), Thermalytix showed a sensitivity of 100% (95% CI, 69.2-100) and a specificity of 81.7% (95% CI, 74.7-87.4). In women with ACR categories ‘c’ and ‘d’ dense breasts, mammography reported 22% of them as inconclusive (BI-RAD 0), while in the same sub-set of the population Thermalytix demonstrated a sensitivity of 100%. Conclusions: The AI-based Thermalytix demonstrated high sensitivity and specificity in the study cohort. It also fared well in women younger than 50 years and pre-menopausal women where routine mammography screening yields low sensitivity. Overall, this study introduces Thermalytix, a promising radiation-free, automated, and privacy-aware test that can supplement mammography for routine screening of women, especially in women with dense breast tissue, and has the potential to influence the clinical practice in LMICs by making breast cancer screening portable and affordable. Performance of Thermalytix and mammography in women with high breast densities (ACR categories ‘c’ and ‘d’ breasts). Clinical trial information: NCT04688086. [Table: see text]