scholarly journals Performance characteristics of high performance liquid chromatography, first order derivative UV spectrophotometry and bioassay for fluconazole determination in capsules

Química Nova ◽  
2012 ◽  
Vol 35 (3) ◽  
pp. 530-534 ◽  
Author(s):  
Josilene Chaves Ruela Corrêa ◽  
Camila Reichman ◽  
Hérida Regina Nunes Salgado ◽  
Cristina Duarte Vianna-Soares
2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Zamir G. Khan ◽  
Amod S. Patil ◽  
Atul A. Shirkhedkar

Four simple, rapid, accurate, precise, reliable, and economical UV-spectrophotometric methods have been proposed for the determination of tadalafil in bulk and in pharmaceutical formulation. “Method A” is first order derivative UV spectrophotometry using amplitude, “method B” is first order derivative UV spectrophotometry using area under curve technique, “method C” is second order derivative UV spectrophotometry using amplitude, and “method D” is second order derivative UV spectrophotometry using area under curve technique. The developed methods have shown best results in terms of linearity, accuracy, precision, and LOD and LOQ for bulk drug and marketed formulation as well. In N,N-dimethylformamide, tadalafil showed maximum absorbance at 284 nm. For “method A” amplitude was recorded at 297 nm while for “method B” area under curve was integrated in the wavelength range of 290.60–304.40 nm. For “method C” amplitude was measured at 284 nm while for “method D” area under curve was selected in the wavelength range of 280.80–286.20 nm. For methods A and B, tadalafil obeyed Lambert-Beer’s law in the range of 05–50 μg/mL while for “methods C and D”, tadalafil obeyed Lambert-Beer’s law in the range of 20–70 μg/mL, and-for “methods A, B, C, and D” the correlation coefficients were found to be > than 0.999.


2014 ◽  
Vol 64 (4) ◽  
pp. 433-446 ◽  
Author(s):  
Mohamed M. Hefnawy ◽  
Mostafa S. Mohamed ◽  
Mohammed A. Abounassif ◽  
Amer M. Alanazi ◽  
Gamal A. E. Mostafa

Abstract High performance liquid chromatography (HPLC) and second-order derivative spectrophotometry have been used for simultaneous determination of pravastatin (PS) and fenofibrate (FF) in pharmaceutical formulations. HPLC separation was performed on a phenyl HYPERSIL C18 column (125 mm × 4.6 mm i.d., 5 μm particle diameter) in the isocratic mode using a mobile phase acetonitrile/0.1 % diethyl amine (50:50, V/V, pH 4.5) pumped at a flow rate of 1.0 mL min-1. Measurement was made at 240 nm. Both drugs were well resolved on the stationary phase, with retention times of 2.15 and 5.79 min for PS and FF, respectively. Calibration curves were linear (R = 0.999 for PS and 0.996 for FF) in the concentration range of 5-50 and 20-200 µg mL-1 for PS and FF, respectively. Pravastatin and fenofibrate were quantitated in combined preparations also using the second-order derivative response at 237.6 and 295.1 nm for PS and FF, respectively. Calibration curves were linear, with the correlation coefficient R = 0.999 for pravastatin and fenofibrate, in the concentration range of 5-20 and 3-20 µg mL-1 for PS and FF, respectively. Both methods were fully validated and compared, the results confirmed that they were highly suitable for their intended purpose.


2017 ◽  
Vol 50 (12) ◽  
pp. 851-856 ◽  
Author(s):  
Sridevi Chigurupati ◽  
Selvadurai Muralidharan ◽  
Lim Sue Cin ◽  
Wei Yin Raser ◽  
Kumaraswamy Santhi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document