scholarly journals Diagnostic reference levels for the most frequent radiological examinations carried out in Brazil

Author(s):  
Marcelo B. Freitas ◽  
Elisabeth M. Yoshimura
2002 ◽  
Vol 101 (1) ◽  
pp. 411-413 ◽  
Author(s):  
D. Berni ◽  
C. Gori ◽  
B. Lazzari ◽  
S. Mazzocchi ◽  
F. Rossi ◽  
...  

Author(s):  
Anja Almén ◽  
Jónína Guðjónsdóttir ◽  
Nils Heimland ◽  
Britta Højgaard ◽  
Hanne Waltenburg ◽  
...  

Objective: The purpose of this study was to explore the feasibility to determine regional diagnostic reference levels (RDRLs) for paediatric conventional and CT examinations using the European guidelines and to compare RDRLs derived from weight and age groups, respectively. Methods: Data were collected from 31 hospitals in 4 countries, for 7 examination types for a total of 2978 patients. RDRLs were derived for each weight and age group, respectively, when the total number of patients exceeded 15. Results: It was possible to derive RDRLs for most, but not all, weight-based and age-based groups for the seven examinations. The result using weight-based and age-based groups differed substantially. The RDRLs were lower than or equal to the European and recently published national DRLs. Conclusion: It is feasible to derive RDRLs. However, a thorough review of the clinical indications and methodologies has to be performed previous to data collection. This study does not support the notion that DRLs derived using age and weight groups are exchangeable. Advances in knowledge: Paediatric DRLs should be derived using weight-based groups with access to the actual weight of the patients. DRLs developed using weight differ markedly from those developed with the use of age. There is still a need to harmonize the method to derive solid DRLs for paediatric radiological examinations.


2019 ◽  
Vol 46 (6) ◽  
pp. 341-342 ◽  
Author(s):  
Julien Ognard ◽  
David Bourhis ◽  
René Anxionnat ◽  
Douraied Ben Salem

Hand ◽  
2021 ◽  
pp. 155894472199425
Author(s):  
Kiran R. Madhvani ◽  
Matthew J. R. Clark ◽  
Alex A. J. Kocheta

Background: Diagnostic reference levels are radiation dose levels in medical radiodiagnostic practices for typical examinations for groups of standard-sized individuals for broadly defined types of equipment. This study aimed to contribute to national diagnostic reference levels for common hand and wrist procedures using mini C-arm fluoroscopy. Small joint and digital fracture procedure diagnostic reference levels have not been reported in significant numbers previously with procedure-level stratification. Methods: Data were collected from fluoroscopy logbooks and were cross-referenced against the audit log kept on fluoroscopy machines. A total of 603 procedures were included. Results: The median radiation dose for wrist fracture open fixation was 2.73 cGycm2, Kirschner wiring (K-wiring) procedures was 2.36 cGycm2, small joint arthrodesis was 1.20 cGycm2, small joint injections was 0.58 cGycm2, and phalangeal fracture fixation was 1.05 cGycm2. Conclusions: Wrist fracture fixation used higher radiation doses than phalangeal fracture fixation, arthrodeses, and injections. Injections used significantly less radiation than the other procedures. There are significant differences in total radiation doses when comparing these procedures in hand and wrist surgery. National and international recommendations are that institutional audit data should be collected regularly and should be stratified by procedure type. This study helps to define standards for this activity by adding to the data available for wrist fracture diagnostic reference levels and defining standards for digital and injection procedures.


2021 ◽  
pp. jnmt.121.262175
Author(s):  
Mashari Alnaaimi ◽  
Mousa Alduaij ◽  
Musab Algaily ◽  
Fisal Shanawey ◽  
Talal Mohammedzein ◽  
...  

Author(s):  
Khalid M. Aloufi ◽  
Fahad H. Alhazmi ◽  
Osama M. Abdulaal ◽  
Abdualaziz A. Qurashi

2022 ◽  
Author(s):  
M. El Mansouri ◽  
M. Talbi ◽  
A. Choukri ◽  
O. Nhila ◽  
M. Aabid

In Morocco, the radiation doses received by adult patients are increasing due to the number of CT examinations performed and the larger number of computed tomography (CT) scanners installed. The aim of this study was to evaluate the radiation doses received by patients for the most common adult CT examinations in order to establish local diagnostic reference levels (DRLs). Data from 1016 adult patients were collected during 3 months from four Moroccan hospitals. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for the most common examinations including head, chest and abdomen. The DRL for each examination was compared with other studies. The established DRLs in Morocco in terms of CTDIvol were 57.4, 12.3 and 10.9 for CT examinations of the head, chest, abdomen, respectively. For DLP, they were 1020, 632 and 714, respectively. These established DRLs for CTDIvol were almost similar to the UK DRLs at all examinations, higher than the Egyptian DRLs and lower than the Japanese DRLs at the head CT examination, lower than the DRLs from Egypt and Japan at the CT abdomen examination. In terms of DLP, the DRLs were higher than those of the British studies, lower than those of the Egyptian and Japanese studies at the head CT examination were higher at chest CT and lower at abdominal CT than those of all selected studies. The higher level of established DRLs in our study demonstrates the requirement of an optimization process while keeping a good image quality for a reliable diagnosis.


Sign in / Sign up

Export Citation Format

Share Document