scholarly journals A comparative study of two separate analytical techniques for the simultaneous determination of diclofenac sodium and diacerein from combined dosage form

Author(s):  
Sanhita Basu Mallick ◽  
Helen Chattopadhyay ◽  
Amit Kumar De ◽  
Sriparna Datta
2011 ◽  
Vol 8 (3) ◽  
pp. 1206-1211
Author(s):  
Madhukar A. Badgujar ◽  
Satish G. Pingale ◽  
Kiran V. Mangaonkar

A simple, precise and rapid isocratic reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of paracetamol, chlorzoxazone and diclofenac sodium from tablet dosage form. The chromatographic separation was performed on an inertsil C18column (250 mm × 4.6 mm i.d 5 µm particle size). Mobile phase consisted of a mixture of phosphate buffer (0.02 M KH2PO4, pH adjusted to 3.7 using orthophosphoric acid), acetonitrile and methanol in the ratio of (25: 25: 50) at a flow rate of 1.0 mL/min. The wavelength was set at 220 nm. The proposed method was validated for linearity, accuracy, precision, LOD and LOQ. The calibration was linear over the range of 50-150 µg/mL for paracetamol, 50-150 µg/mL for chlorzoxazone and 5-15 µg/mL for diclofenac sodium. The retention times were found as 2.8 min for paracetamol, 4.2 min for chlorzoxazone and 6.4 min for diclofenac sodium. The method can be easily adopted for quality control analysis.


2019 ◽  
Vol 15 (6) ◽  
pp. 635-641
Author(s):  
Nadia M. Mostafa ◽  
Ghada M. Elsayed ◽  
Nagiba Y. Hassan ◽  
Dina A. El Mously

Background:The concept of green analytical chemistry prevails due to the growing environmental pollution.Objective:Our attempts are to develop simple and eco-friendly method which is non-harmful to the environment by producing minimal waste. In this context, a green liquid chromatographic method was applied for the simultaneous determination of chlorpheniramine maleate, pseudoephedrine hydrochloride and propyphenazone in their combined dosage form.Methods:Separation was carried out using X select HSS RP C18 analytical column (250 × 4.6 mm, 5μm) using methanol - 0.02 M phosphate buffer pH 3 - triethylamine (60:40: 0.1, by volume) as a mobile phase. The separated peaks were detected at 215 nm at a flow rate 1.0 mL/min.Results:Quantification was done over the concentration ranges of 1-25 µg/mL for chlorpheniramine maleate, 5-35 µg/mL for pseudoephedrine hydrochloride and 10-120 µg/mL for propyphenazone. The suggested method was validated with regard to linearity, accuracy and precision according to the International Conference on Harmonization guidelines with good results.Conclusion:It could be used as a safer alternative for routine analysis of the mentioned drugs in quality control laboratories.


Sign in / Sign up

Export Citation Format

Share Document