MONTE CARLO SIMULATIONS OF CO2 SORPTION IN NANOPOROUSCARBONS

Author(s):  
M. Konstantakou ◽  
Th. A. Steriotis ◽  
E. S. Kikkinides ◽  
A. K. Stubos
2021 ◽  
Vol 5 (3) ◽  
pp. 55
Author(s):  
Siddharth Gautam ◽  
David R. Cole

Adsorption of fluids in nanoporous materials is important for several applications including gas storage and catalysis. The pore network in natural, as well as engineered, materials can exhibit different degrees of connectivity between pores. While this might have important implications for the sorption of fluids, the effects of pore connectivity are seldom addressed in the studies of fluid sorption. We have carried out Monte Carlo simulations of the sorption of ethane and CO2 in silicalite, a nanoporous material characterized by sub-nanometer pores of different geometries (straight and zigzag channel like pores), with varied degrees of pore connectivity. The variation in pore connectivity is achieved by selectively blocking some pores by loading them with methane molecules that are treated as a part of the rigid nanoporous matrix in the simulations. Normalized to the pore space available for adsorption, the magnitude of sorption increases with a decrease in pore connectivity. The increased adsorption in the systems where pore connections are removed by blocking them is because of additional, albeit weaker, adsorption sites provided by the blocker molecules. By selectively blocking all straight or zigzag channels, we find differences in the absorption behavior of guest molecules in these channels.


Author(s):  
Matthew T. Johnson ◽  
Ian M. Anderson ◽  
Jim Bentley ◽  
C. Barry Carter

Energy-dispersive X-ray spectrometry (EDS) performed at low (≤ 5 kV) accelerating voltages in the SEM has the potential for providing quantitative microanalytical information with a spatial resolution of ∼100 nm. In the present work, EDS analyses were performed on magnesium ferrite spinel [(MgxFe1−x)Fe2O4] dendrites embedded in a MgO matrix, as shown in Fig. 1. spatial resolution of X-ray microanalysis at conventional accelerating voltages is insufficient for the quantitative analysis of these dendrites, which have widths of the order of a few hundred nanometers, without deconvolution of contributions from the MgO matrix. However, Monte Carlo simulations indicate that the interaction volume for MgFe2O4 is ∼150 nm at 3 kV accelerating voltage and therefore sufficient to analyze the dendrites without matrix contributions.Single-crystal {001}-oriented MgO was reacted with hematite (Fe2O3) powder for 6 h at 1450°C in air and furnace cooled. The specimen was then cleaved to expose a clean cross-section suitable for microanalysis.


1979 ◽  
Vol 40 (C7) ◽  
pp. C7-63-C7-64
Author(s):  
A. J. Davies ◽  
J. Dutton ◽  
C. J. Evans ◽  
A. Goodings ◽  
P.K. Stewart

Sign in / Sign up

Export Citation Format

Share Document