DISCUSSION. PREDICTING THE STRENGTH OF REINFORCED CONCRETE DEEP BEAMS WITH WEB OPENINGS.

1981 ◽  
Vol 71 (2) ◽  
pp. 615-616 ◽  
Author(s):  
LA KUBIK ◽  
JE GIBSON
Structures ◽  
2020 ◽  
Vol 27 ◽  
pp. 506-524 ◽  
Author(s):  
Ata El-Kareim ◽  
Ahmed Arafa ◽  
Amal Hassanin ◽  
Mohamed Atef ◽  
Ahmed Saber

Author(s):  
Nabeel A. Al-Bayati ◽  
Bassman R. Muhammed ◽  
Muroj F. Oda

Results of test on seven simply supported self-compacting reinforced concrete deep beams, including six of these beams containing circular openings in center of load path are reported in this paper. The objective of the tests was determined the influence of, changing shear span to effective depth ratio a/d, the existence of circular openings in shear span and using inclined strips of carbon fiber polymer (CFRP) on behavior of deep beams. The general trend in crack pattern, the load-deflection response, and the mode of failure of reinforced SCC deep beams were also investigated. All specimens had the same geometry, details of the flexure and shear reinforcement in both vertical and horizontal directions and they were tested under symmetrical two-point loads up to failure. The experimental results revealed that the web openings within shear spans caused an important reduction in the deep beam capacity by 50% when compared with the corresponding solid beam. The increase a/d ratio from 0.8 to 1.2 decreases the ultimate load by 21.7% and 22.5 % for the reference unstrengthened beam and strengthened beam, respectively, also it was found that the externally inclined CFRP strips in deep beams increased the ultimate strength up to 39.5%, and enhanced the stiffness of deep beams with openings.


2020 ◽  
Vol 43 (7) ◽  
pp. 694-705
Author(s):  
Wen-Yao Lu ◽  
Guo-Zhen Lin ◽  
Chien-Chuang Tseng ◽  
Sheng-Ji Lin

2018 ◽  
Vol 7 (4.20) ◽  
pp. 546
Author(s):  
Ahlam Sader Mohammed ◽  
Laith Nasser Hussain

A nonlinear limited component display is utilized to approve the consequences of limited component investigation with that of test work got from written works with the end goal to foresee execution of self-compacted strengthened solid; profound pillars incorporate roundabout web openings. Six indistinguishable profound bars were considered for this reason; one of them was strong that considered as a control bar. ANSYS PC program was utilized to accomplish the investigation of these bars. Examination between the test and limited component strategy results shows a satisfactory understanding with the goal that the proposed model can be embraced in future for further investigations. The diagnostic tests which were improved the situation different cases considered showed that the heap redirection conduct and a definitive burdens are in great concurrence with the distributed libratory results. The outcomes demonstrate that most extreme contrast between the anticipated numerical extreme burdens to the trial extreme load for all cases was under (14%); while the greatest rate distinction for redirection esteems was about 11%. Likewise, the extent of the openings and its area influence the heap conveying limit of the shafts.  


Sign in / Sign up

Export Citation Format

Share Document