scholarly journals An Experimental Study of Microstructure and Mechanical Behavior of Alloy 625 Weld Overlay Deposited On ASTM A516 Grade 70

Author(s):  
Mohammad J. Moradi ◽  
Mostafa Ketabchi
Author(s):  
Petrônio Zumpano ◽  
Alexandre G. Garmbis ◽  
Eduardo V. Oazen ◽  
Luis Guilherme T. S. Leite ◽  
Rafael N. Silva

This paper describes different alternatives to be adopted to assess the integrity of weld overlays of flexible joints and lined pipes in offshore pipeline and riser projects. Protective layers are adopted as an interesting alternative to full thickness corrosion resistant alloys due to the possibility to adopt carbon steel as base material in order to reduce overall material costs. UNS N06625 (alloy 625) is generally selected for internal layers, such as weld overlay steels, lined pipes or clad pipes because of its sulfide stress cracking (SSC) resistance and outstanding weldability. However, unless the long-term integrity of the cladding or overlay as a protective layer can be demonstrated under the intended service conditions, the base material shall also be resistant against sulfide stress corrosion cracking. Due to low resistance of carbon steel to corrosion fatigue in the presence of contaminants in fluid content, the rupture of thickness of CRA (Corrosion Resistant Alloy) layer becomes a failure mode. An Engineering Critical Assessment (ECA) shall be performed in order to assess if circumferential planar flaws in weld overlay regions will not propagate through the CRA layer, thus exposing the base material, when submitted to critical cyclic loads during the service life. Such analysis would involve fatigue crack growth simulation and surface interaction of full circumferential embedded defects to determine the maximum weld overlay pass height to be limited by machining. This limited height of machined layers should guarantee that a full circumferential flaw will withstand the operational fatigue life. However, this is a very time consuming manufacturing process and would implicate additional concerns for long extensions due to out of straightness and out of roundness. Alternatively, the ECA results may be used to determine the flaw acceptance criteria and required probability of detection of volumetric non-destructive testing. Recent developments in ultrasonic inspection were successfully adopted and represent a better solution for alloy 625 weld overlay in terms of project scheduling and manufacturing costs. Radiographic testing may also be used provided it meets the required sensitivity, in terms of image quality indicators (IQI). Anyway, validation tests shall be performed to demonstrate adequate reliability to detect the minimum required flaw height.


2017 ◽  
Vol 176 ◽  
pp. 608-616 ◽  
Author(s):  
Fangyuan Zhang ◽  
Huisu Chen ◽  
Xiangyu Li ◽  
Hui Li ◽  
Tao Lv ◽  
...  

2010 ◽  
Vol 163-167 ◽  
pp. 651-654
Author(s):  
Tian Hua Zhou ◽  
Shao Feng Nie ◽  
Xiang Bin Liu ◽  
Guang Yi Li

18 specimens of cold-formed steel three limbs built-up section members are tested under axial compression load in this paper. The section forms are divided into two categories: A and B. Load-displacement (P-Δ) curves and failure characteristics of specimens are obtained. The results show that: As to section A members, the failure characteristics of LC, MC and SC series of specimens are flexural-torsional buckling, torsional buckling and distortional buckling, local buckling and distortional buckling. As to section B members, the failure characteristics of LC, MC series of specimens are flexural buckling, while local buckling and distortional buckling for members of SC series.


Sign in / Sign up

Export Citation Format

Share Document