Experimental and finite element analysis study of 3D magnetic field sensing for pulsed magnetic flux leakage defect characterisation

2011 ◽  
Vol 53 (9) ◽  
pp. 497-506 ◽  
Author(s):  
Ying Tang ◽  
MengChun Pan ◽  
FeiLu Luo ◽  
XiangLin Tan
2014 ◽  
Vol 620 ◽  
pp. 127-132
Author(s):  
Xiao Wen Xi ◽  
Shang Kun Ren ◽  
Li Hua Yuan

Using large finite element analysis (FEA) software ANSYS, the stress-magnetization effect on 20# steel specimens with different shape notches is simulated under the geomagnetic field and tensile load. With the stimulation, the magnetic flux leakage fields at certain positions of the surface specimen were measured. Through analysis the relationship between the magnetic flux leakage fields of certain points with tensile stress, the results showed that the magnetic field value at certain positions of specimen surface first decreases and then increases along with the increase of stress, which is called magnetization reversal phenomenon; Different gaps and different positions of the specimen show different magnetization reversal rules; By measuring the maximal variation of the magnetic field value △Hmax at certain positions of the surface specimen and by analyzing its change law, we can roughly estimate specimen stress size and distribution regularity of stress. Moreover, this article also discusses the effect of lifts-off of the probe on the law of stress magnetization.


2014 ◽  
Vol 599-601 ◽  
pp. 321-325
Author(s):  
Li Qiang Sun ◽  
Hong Bo Zhu ◽  
Ming Xie ◽  
Ji Xia Li

In view of the petroleum and petrochemical characteristics of horizontal tank, ANSYS software of finite element analysis was carried out on the horizontal tank within the magnetic flux leakage testing, analyzes the influencing factors of defect magnetic flux leakage signals. Experiments verify the finite element analysis results, the experimental results show that the research of horizontal tank within the magnetic flux leakage detection effect is obvious.


2016 ◽  
Vol 853 ◽  
pp. 514-518
Author(s):  
Zhi Jun Yang ◽  
De Shu Chen ◽  
Liang Chen ◽  
Yu Zhuo Liu ◽  
Ran An ◽  
...  

Storage tank is an essential vessel in petrochemical industry, and the corrosion of tank is an important reason for the safety hazard. The corrosion of tank bottom plate is more serious than the tank wall, and it is not easy to check and repair, when damaged to a certain extent it will cause the leakage of the media, then lead to waste of energy, environmental pollution, at the same time it will cause a major accident. Magnetic flux leakage testing is widely used in the field of tank floor inspection with the advantages of fast scanning speed, accurate results and so on. In this paper, the finite element simulation and analysis of the corrosion defect leakage magnetic field is used to obtain the data, and the characteristic of the leakage magnetic field is extracted. The effect of defect depth and width and shape on the magnetic flux leakage field is studied, and the distribution curve of the magnetic flux leakage field is obtained.


2013 ◽  
Vol 22 (1) ◽  
pp. 018103 ◽  
Author(s):  
Jian Feng ◽  
Jun-Feng Zhang ◽  
Sen-Xiang Lu ◽  
Hong-Yang Wang ◽  
Rui-Ze Ma

2011 ◽  
Vol 201-203 ◽  
pp. 1623-1626
Author(s):  
Qiang Song

Magnetic flux leakage (MFL) is a non-destructive testing method used to inspect ferrous materials. However, apparatus parameters could affect the MFL inspection tool’s ability to characterize anomalies. In this paper, MFL signals obtained during the inspection of pipes have been simulated using three-dimensional finite element analysis and the effects of magnet assembly on MFL signals are investigated. According to numerical simulations, an increase in the leakage flux amplitude is observed with an increase in the permanent magnet size and the inflexion point may indicate the presence of magnetizing pipe wall to near saturation. It clearly illustrates degradation in the MFL with increasing backing iron length. The relationship between MFL apparatus parameters and MFL signals could be utilized in the MFL technique to characterize the defect.


2013 ◽  
Vol 718-720 ◽  
pp. 1000-1005
Author(s):  
Li Jian Yang ◽  
Sen Lin Zhang ◽  
Song Wei Gao

In order to solve the need of the oil and gas pipeline defect quantification in the real-time online defecting, magnetic flux leakage inspection method was applied to oil and gas pipeline inspection. According to the basic theory of the electromagnetic field, finite element solution of electromagnetic field and ANSYS electromagnetic field calculation theory, using the function of ANSYS 's simulation and calculation for magnetic field, three-dimensional finite element model of the oil and gas pipeline defect was built up. Through simulating, the relationship between defect signal and defect size was found, the optimal distance of the hall sensor lift-off value was verified, the best magnetization of leakage magnetic field was discussed, and various factors to influence the magnetic flux leakage signal is analyzed.