scholarly journals Validation of an equine serum amyloid A assay with an unusually broad working range

2019 ◽  
Author(s):  
Stine Jacobsen ◽  
Anne Mette Vinther ◽  
Mads Kjelgaard-Hansen ◽  
Lise Nikolic Nielsen

Abstract Background Serum amyloid A (SAA) is a major equine acute phase protein and of great value in detection and monitoring of inflammation. A new immunoturbidometric assay based on monoclonal antibodies (VET-SAA, Eiken Chemical Co., Japan) may be useful for SAA measurements in routine diagnostic laboratories. The aim of the study was to validate the VET-SAA immunoturbidometric assay and use it to measure serum SAA concentrations in a variety of clinical cases. Precision was assessed by intra- and interassay coefficients of variation of repeated measurements of serum pools (low, intermediate, high concentrations of SAA). Accuracy was estimated by linearity under dilution. Detection limit was determined by replicate determinations of ionized water. Measurements were compared to measurements performed in a previously validated SAA assay (LZSAA assay, Eiken Chemical Co., Japan). Subsequently, the VET-SAA assay was used for measuring serum SAA concentrations in horses with and without inflammation. Results Detection limit was 1.2 mg/L. Without modifications, the assay measured SAA concentrations with acceptable reliability in a broad concentration range (0 to > 6000 mg/L). In the 0-3000 mg/L range, the assay demonstrated good precision and accuracy, and concentrations correlated well with those obtained in the LZSAA assay, albeit with a slight systematic bias. Concentrations of SAA assessed in horses with and without inflammation followed the expected pattern, with significantly higher concentrations in horses with systemic inflammation than in healthy horses and horses with non-inflammatory disease. Conclusions The assay was unique in its ability to measure SAA concentrations with acceptable reliability over an extreme concentration range. This is relevant in the equine species, where SAA concentrations may reach very high concentrations.

2019 ◽  
Author(s):  
Stine Jacobsen ◽  
Anne Mette Vinther ◽  
Mads Kjelgaard-Hansen ◽  
Lise Nikolic Nielsen

Abstract Background Serum amyloid A (SAA) is a major equine acute phase protein and of great value in detection and monitoring of inflammation. A new immunoturbidometric assay based on monoclonal antibodies (VET-SAA, Eiken Chemical Co., Japan) may be useful for SAA measurements in routine diagnostic laboratories. The aim of the study was to validate the VET-SAA immunoturbidometric assay and use it to measure serum SAA concentrations in a variety of clinical cases. Precision was assessed by intra- and interassay coefficients of variation of repeated measurements of serum pools (low, intermediate, high concentrations of SAA). Accuracy was estimated by linearity under dilution. Detection limit was determined by replicate determinations of ionized water. Measurements were compared to measurements performed in a previously validated SAA assay (LZSAA assay, Eiken Chemical Co., Japan). Subsequently, the VET-SAA assay was used for measuring serum SAA concentrations in horses with and without inflammation. Results Detection limit was 1.2 mg/L. Without modifications, the assay measured SAA concentrations with acceptable reliability in a broad concentration range (0 to > 6000 mg/L). In the 0-3000 mg/L range, the assay demonstrated good precision and accuracy, and concentrations correlated well with those obtained in the LZSAA assay, albeit with a slight systematic bias. Concentrations of SAA assessed in horses with and without inflammation followed the expected pattern, with significantly higher concentrations in horses with systemic inflammation than in healthy horses and horses with non-inflammatory disease. Conclusions The assay was unique in its ability to measure SAA concentrations with acceptable reliability over an extreme concentration range. This is relevant in the equine species, where SAA concentrations may reach very high concentrations.


2019 ◽  
Vol 15 (1) ◽  
Author(s):  
Stine Jacobsen ◽  
Anne Mette Vinther ◽  
Mads Kjelgaard-Hansen ◽  
Lise Nikolic Nielsen

Abstract Background Serum amyloid A (SAA) is a major equine acute phase protein and of great value in detection and monitoring of inflammation. A new immunoturbidometric assay based on monoclonal antibodies (VET-SAA, Eiken Chemical Co., Japan) may be useful for SAA measurements in routine diagnostic laboratories. The aim of the study was to validate the VET-SAA immunoturbidometric assay and use it to measure serum SAA concentrations in a variety of clinical cases. Precision was assessed by intra- and interassay coefficients of variation of repeated measurements of serum pools (low, intermediate, high concentrations of SAA). Accuracy was estimated by linearity under dilution. Detection limit was determined by replicate determinations of ionized water. Measurements were compared to measurements performed in a previously validated SAA assay (LZSAA assay, Eiken Chemical Co., Japan). Subsequently, the VET-SAA assay was used for measuring serum SAA concentrations in horses with and without inflammation. Results Detection limit was 1.2 mg/L. Without modifications, the assay measured SAA concentrations with acceptable reliability in a broad concentration range (0 to > 6000 mg/L). In the 0–3000 mg/L range, the assay demonstrated good precision and accuracy, and concentrations correlated well with those obtained in the LZSAA assay, albeit with a slight systematic bias. Concentrations of SAA assessed in horses with and without inflammation followed the expected pattern, with significantly higher concentrations in horses with systemic inflammation than in healthy horses and horses with non-inflammatory disease. Conclusions The assay was unique in its ability to measure SAA concentrations with acceptable reliability over an extreme concentration range. This is relevant in the equine species, where SAA concentrations may reach very high concentrations.


1999 ◽  
Vol 189 (2) ◽  
pp. 395-402 ◽  
Author(s):  
Shao Bo Su ◽  
Wanghua Gong ◽  
Ji-Liang Gao ◽  
Weiping Shen ◽  
Philip M. Murphy ◽  
...  

We have previously reported (Badolato, R., J.M. Wang, W.J. Murphy, A.R. Lloyd, D.F. Michiel, L.L. Bausserman, D.J. Kelvin, and J.J. Oppenheim. 1994. J. Exp. Med. 180:203; Xu, L., R. Badolato, W.J. Murphy, D.L. Longo, M. Anver, S. Hale, J.J. Oppenheim, and J.M. Wang. 1995. J. Immunol. 155:1184.) that the acute phase protein serum amyloid A (SAA) is a potent chemoattractant for human leukocytes in vitro and mouse phagocytes in vivo. To identify the signaling mechanisms, we evaluated patterns of cross-desensitization between SAA and other leukocyte chemoattrctants. We found that the chemotactic bacterial peptide, N-formyl- methionyl-leucyl-phenylalanine (fMLP), was able to specifically attenuate Ca2+ mobilization in human phagocytes induced by SAA, but only at very high concentrations, suggesting that SAA uses a low affinity fMLP receptor. Here we demonstrate that SAA selectively induced Ca2+ mobilization and migration of HEK cells expressing FPRL1, a human seven-transmembrane domain phagocyte receptor with low affinity for fMLP, and high affinity for lipoxin A4. Furthermore, radiolabeled SAA specifically bound to human phagocytes and FPRL1-transfected 293 cells. In contrast, SAA was not a ligand or agonist for FPR, the high affinity fMLP receptor. Thus, SAA is the first chemotactic ligand identified for FPRL1. Our results suggest that FPRL1 mediates phagocyte migration in response to SAA.


2017 ◽  
Vol 43 (4) ◽  
pp. 417-420 ◽  
Author(s):  
Sarah N. Miller ◽  
Michelle Davis ◽  
Jorge A. Hernandez ◽  
Judy St. Leger ◽  
Carolyn Cray ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document