scholarly journals Preliminary Outcomes of the Cementless UNITED Hip System for primary Total Hip Arthroplasty at a Minimum Two-year Follow-up

2020 ◽  
Author(s):  
Fernando Diaz Dilernia ◽  
Agustin Garcia-Mansilla ◽  
Agustin Albani-Forneris ◽  
Pablo Slullitel ◽  
Gerardo Zanotti ◽  
...  

Abstract Introduction: This study aimed to report the initial results of the cementless UNITED hip system in primary total hip arthroplasty (THA) with a minimum follow-up of 2 years. Methods We retrospectively studied a consecutive series of 203 cementless THAs in 180 patients operated between 2015–2017. We included 89 female and 91 male patients with a mean age of 67 (28 to 89) years. The mean follow-up was 40 (29 to 62) months. Clinical outcome scores and radiographs were measured. Survival was calculated defining failure as the need for any further femoral or acetabular revision, irrespective of the reason. Results No femoral component loosening was detected. One patient had a Vancouver-B1 intraoperative periprosthetic femoral fracture treated with implant retention and cerclage wires. Two acetabular components were revised for aseptic loosening. Three patients suffered an acute infection treated with debridement, antibiotics, and implant retention. The mean Merle d'Aubigné et Postel scores improved from 13 (4 to 16) points preoperatively to 17 (12 to 18) points at the latest follow-up (p < 0.001). At a mean time of 40 months of follow-up, the survival was 99% and 100% for the acetabular and the femoral components, respectively. Conclusion This cementless design showed excellent preliminary outcomes in terms of fixation and patient satisfaction, comparable to that of other well-known similar systems.

2008 ◽  
Vol 90 (8) ◽  
pp. 658-662 ◽  
Author(s):  
Ashley W Blom ◽  
Mark Rogers ◽  
Adrian H Taylor ◽  
Giles Pattison ◽  
Sarah Whitehouse ◽  
...  

INTRODUCTION The aim of this study was to determine the incidence and outcome of dislocation after total hip arthroplasty at our unit. PATIENTS AND METHODS In total, 1727 primary total joint arthroplasties and 305 revision total hip arthroplasties were performed between 1993 and 1996 at our unit. We followed up 1567 (91%) of the primary hip arthroplasties and 284 (93%) of the revision hip arthroplasties at 8–11 years after surgery. Patients were traced by postal questionnaire, telephone interview or examination of case notes of the deceased. RESULTS The dislocation rates by approach were 23 out of 555 (4.1%) for the posterior approach, 0 out of 120 (0%) for the Omega approach and 30 out of 892 (3.4%) for the modified Hardinge approach. Of dislocations after primary total hip arthroplasty, 58.5% were recurrent. The mean number of dislocations per patient was 2.81. Overall, 8.1% of revision total hip arthroplasties dislocated. 70% of these became recurrent. The mean number of dislocations per patient was 2.87. The vast majority of dislocations occurred within 2 months of surgery. DISCUSSION To our knowledge, this is the largest multisurgeon audit of dislocation after total hip arthroplasty published in the UK. The follow-up of 8–11 years is longer than most comparable studies. The results of this study can be used to inform patients as to the risk and outcome of dislocation, as well as to the risk of further dislocation.


2019 ◽  
pp. 112070001989334
Author(s):  
Enrico Tassinari ◽  
Francesco Castagnini ◽  
Federica Mariotti ◽  
Federico Biondi ◽  
Maurizio Montalti ◽  
...  

Introduction: Aim of this study was to describe the clinical outcomes of 16 patients with iliopsoas (IP) impingement after primary total hip arthroplasty (THA), treated with an arthroscopic tendon release. Methods: 16 patients (11 females/5 males), with a mean age of 57.8 ± 11.1 years (age at THA: 54.4 ± 11 years) and a diagnosis of IP impingement after primary THA, were treated with the Wettstein tenotomy. Preoperatively, every patient underwent a diagnostic ultrasonography guided peritendinous injection and a computed tomography (CT) scan. Every patient was clinically evaluated using WOMAC score. Subjective pain relief and active hip flexion strength were measured. Results: No complications related to arthroscopy were detected. Every cup was prominent with a mean axial overhang of 13 ± 4.8 mm (range 5–20 mm). At a mean follow-up of 27 ± 20.1 months (range 6–48 months), the WOMAC score was 83.7 ± 10.1 points. 13 patients out of 16 (81.3%) had a complete pain relief. 14 patients out of 16 (88%) regained full active hip flexion strength at the final follow-up. 1 patient was scheduled for cup revision after 6 months, due to persistent symptomatology. No demographic data or CT measurements about cup position statistically influenced the outcome. Conclusions: When preceded by an appropriate diagnosis, arthroscopic tenotomy proved safe and effective for IP impingement, regardless the magnitude of cup protrusion.


2010 ◽  
Vol 16 (3) ◽  
pp. 7-15
Author(s):  
R. M. Tikhilov ◽  
V. M. Shapovalov ◽  
I. I. Artyukh ◽  
V. A. Shubnyakov

The authors reported the outcome at a minimum of five years of 130 consecutive arthroplasties of VerSys ET (Zimmer) in 111 patients. The procedures were performed between 2001 and 2004. In 129 cases (99.2%) Trilogy cup (Zimmer) was used in one case - Muller's acetabular cage (Mathys). The mean age of patients was 49.5 (SD 11.5) (23 to 73), male 76 (58.5%), female - 54 (41.5%), overweight patients 109 (83.8%). Majority of patients had activity in Charnley class A. The most frequent was femur Dorr type A (27,0%) and Dorr type В (66,1%). The mean follow-up was 76 months (60 to 96). The outcomes assessed in 103 patients (120 hips) (92.3%). Outcomes of ten cases were not determined. The mean Harris Hip score improves from 35.1 (SD 8.3) preoperatively to 94.3 (SD 8.5) post-operatively. Kaplan-Meier analysis with revision of the stem as the end-point demonstrated 97,7% survival in term 60 to 96 months, for aseptic loosening - 99,2%. Subsidence of the implants in 61 (50.8%) patients was fixed at a mean follow-up 18.3 (SD3.7) months after surgery and did not progress further. After surgery stem position was neutral 91(75.8%) patients, varus - 14 (12.1%) and valgus - 14 (12.1%). Complications were observed in 8 (6.7%) cases: among them - periprosthetic fractures 6 (5.0%), stem aseptic loosening - 1 (0.8%), recurrent dislocation - 1 (0.8%). Four patients undergone revision surgery We consider the high efficiency of VerSys ET stem use for primary total hip arthroplasty.


Author(s):  
Jesus M. Villa ◽  
Tejbir S. Pannu ◽  
Carlos A. Higuera ◽  
Juan C. Suarez ◽  
Preetesh D. Patel ◽  
...  

AbstractHospital adverse events remain a significant issue; even “minor events” may lead to increased costs. However, to the best of our knowledge, no previous investigation has compared perioperative events between the first and second hip in staged bilateral total hip arthroplasty (THA). In the current study, we perform such a comparison. A retrospective chart review was performed on a consecutive series of 172 patients (344 hips) who underwent staged bilateral THAs performed by two surgeons at a single institution (2010–2016). Based on chronological order of the staged arthroplasties, two groups were set apart: first-staged THA and second-staged THA. Baseline-demographics, length of stay (LOS), discharge disposition, hospital adverse events, and hospital transfusions were compared between groups. Statistical analyses were performed using independent t-tests, Fisher's exact test, and/or Pearson's chi-squared test. The mean time between staged surgeries was 465 days. There were no significant differences in baseline demographics between first-staged THA and second-staged THA groups (patients were their own controls). The mean LOS was significantly longer in the first-staged THA group than in the second (2.2 vs. 1.8 days; p < 0.001). Discharge (proportion) to a facility other than home was noticeably higher in the first-staged THA group, although not statistically significant (11.0 vs. 7.6%; p = 0.354). The rate of hospital adverse events in the first-staged THA group was almost twice that of the second (37.2 vs. 20.3%; p = 0.001). There were no significant differences in transfusion rates. However, these were consistently better in the second-staged THA group. When compared with the first THA, our findings suggest overall shorter LOS and fewer hospital adverse events following the second. Level of Evidence Level III.


2020 ◽  
pp. 112070002096964
Author(s):  
Kirill Gromov ◽  
Nanna H Sillesen ◽  
Thomas Kallemose ◽  
Henrik Husted ◽  
Henrik Malchau ◽  
...  

Background: Introduction of new implants should be monitored closely to capture any signs of compromising patient safety. Vitamin E infused highly-crosslinked polyethylene liners (VEPE) offer the potential for reduced wear. Highwall liners have been hypothesised to result in increased wear and potential liner fractures. The aim of this study was to determine the 3–7-year follow-up of highwall VEPE for primary total hip arthroplasty (THA), focusing on liner-related complications. Methods: We included 1221 consecutive THA operations from July 2010 to May 2014 with minimum follow-up of 3 (3.1–6.8) years Data collected included demographics, implant data, complications, reoperations, and deaths. Data were cross-referenced with the Danish Hip Arthroplasty Registry in order to ensure validity and completeness. Acetabular shell position was measured using Martell Hip Analysis Suite in a subgroup of 931 THAs. Results: Cumulative stem revision and shell revision at 3-year follow-up was 3.4% and 0.4% respectively. There were no revisions due to liner failure. Reason for revision included 11 dislocations, 15 soft-tissue revisions for infection, 44 stem revisions of which 34 were periprosthetic fractures and 13 shell revisions of which 6 were combined shell and stem revisions. Conclusion: Early follow-up of VEPE liners for primary THA have not shown any revisions associated with liner failure. Continued monitoring of new materials are necessary to capture any signs of compromised patient safety.


2015 ◽  
Vol 9 (1) ◽  
pp. 157-162 ◽  
Author(s):  
Sachiyuki Tsukada ◽  
Motohiro Wakui

Objective: The aim of the study was to compare the dislocation rate between total hip arthroplasty (THA) via direct anterior approach (DAA) and via posterior approach (PA). Methods: We compared a consecutive series of 139 THAs via DAA with 177 THAs via PA. All study patients received ceramic-on-ceramic bearing surfaces and similar uncemented prostheses. Dislocation-free survival after THA was estimated using the Kaplan–Meier survival method and compared between groups using the log-rank test. Results: In the DAA group, none of 139 hips experienced dislocations in five-year-average follow-up. In the PA group, seven hips experienced dislocations among 177 hips (4 %). The dislocation was significantly less in the DAA group compared to the PA group (p = 0.033). Conclusion: The dislocation rate of THA via DAA was significantly less than that of THA via PA.


2017 ◽  
Vol 01 (04) ◽  
pp. 200-204 ◽  
Author(s):  
Roby Abraham ◽  
Joseph Scollan ◽  
Patrick Mixa ◽  
Denis Cherkalin ◽  
Jeffrey Varghese ◽  
...  

AbstractGunshot wound (GSW) injuries around the hip joint can lead to debilitating post-traumatic arthritis, requiring a technically demanding primary total hip arthroplasty (THA). These surgeries are often complicated by bullet debris, extensive scaring, prior operations, and altered local anatomy. Although most literature focuses on acute management of GSW around the hip, a few reports detail the mid-term outcomes of GSW patients with primary THA for post-traumatic arthritis. The purpose of this study was to assess the outcomes and complications associated with THA in nine patients with secondary arthritis due to prior GSW injuries. At a mean follow-up of 35 months (range 12–60 months), significant improvement was shown in hip function, activity, and pain levels, and was similar to the outcomes of 18 patients who underwent primary THA for degenerative joint disease. While technically demanding, THA seems to reduce pain and improve function safely and effectively for patients with GSW-induced hip arthritis.