Development of a predictive model to determine the temporal variability in mine feed water quality towards informing and forecasting plant operating strategy – a South African coal mine water treatment plant case study

2016 ◽  
Vol 11 (3) ◽  
pp. 621-633
Author(s):  
J. Nathoo ◽  
E. Hong Gay ◽  
N. Hussain

The feed water quality associated with mine water treatment is typically characterised by a dynamic variability resulting from the fact that the final feed water to the water treatment plant (WTP) can be an amalgamation of water streams emanating from a number of sources. Consequently, the ability to deal with the dynamic nature of the feed water quality towards successful and sustainable mine water treatment goes beyond a proactive approach and requires a systemic, predictive approach. This paper discusses the development of an unsteady state mass balance model on a surface dam located on a coal mine towards predicting the dynamic fluctuations in total dam volume and its total dissolved solids (TDS) concentration in the feed water to a NuWater 20 MLD mobile WTP, comprising chemical conditioning, ultrafiltration and reverse osmosis (RO). The unsteady state mass balance, incorporated water entering the dam via the opencast pits, underground compartments, seasonal rainfall and the RO brine return. Water leaving the dam comprised the feed water to the WTP, partial brine treatment, surface evaporation and seepage. Validation of the model using actual data over an 8-month period showed excellent results. The model showed that without water treatment, the dam would overflow in 218 days. Although the dam's volume could be sustained at the ideal volume by treating 14.2 MLD, its TDS would exceed the maximum environmental limit in 197 days. Consequently, the combination of a 13.2 MLD WTP with a 1 MLD brine treatment plant provided the optimal water treatment strategy to sustainably maintain the dam's TDS concentration and volume within acceptable limits over the 5-year investigation period. This paper demonstrates the importance of using a predictive methodology for forecasting feed water characteristics and as an early warning system for most water treatment systems that are subjected to dynamic conditions.


2014 ◽  
Vol 40 (1) ◽  
pp. 51-59 ◽  
Author(s):  
V. Václavík ◽  
J. Daxner ◽  
J. Valíček ◽  
V. Dombek ◽  
T. Dvorský ◽  
...  

Abstract The results from the experimental research are presented in the abstract. The experimental research involved utilization of the sludge from the mine water treatment plant of Coal Quarry ČSA/Czechoslovak Army/ (hereinafter “ČSA”) and Coal Quarry Jana Švermy (hereinafter “JŠ”) in the segment of thermal insulation mortars. The mine water treatment is described below including chemical and mineralogical sludge composition as the additional component of the binding material in the polyurethane thermal insulation mortars. Furthermore the composition of experimental mixtures of the thermal insulation polyurethane mortar is presented in the work and its physical-mechanical properties. The monitored elements included the strength characteristics, heat conductivity coefficient λ, and water vapour diffusion coefficient μ.





2009 ◽  
Vol 71-73 ◽  
pp. 125-128 ◽  
Author(s):  
Sabrina Hedrich ◽  
Elke Heinzel ◽  
Jana Seifert ◽  
Michael Schlömann

The capacity of a microbiological mine water treatment plant may to be enhanced by understanding the microbiological processes. Therefore different samples from the pilot plant were analyzed by culture-independent and cultivation methods. Dominant bacteria could be isolated on overlay plates or enriched in gradient cultures. To immobilize biomass in the pilot plant, various carrier materials were tested. Sessil, the material currently used in the pilot plant, was the most favored and appropriate material.



2013 ◽  
Vol 32 (4) ◽  
pp. 258-265 ◽  
Author(s):  
Judith S. Tischler ◽  
Claudia Wiacek ◽  
Eberhard Janneck ◽  
Michael Schlömann


2011 ◽  
Vol 45 (18) ◽  
pp. 7685-7692 ◽  
Author(s):  
Sabrina Hedrich ◽  
Heinrich Lünsdorf ◽  
Reinhard Kleeberg ◽  
Gerhard Heide ◽  
Jana Seifert ◽  
...  


Water ◽  
2019 ◽  
Vol 11 (10) ◽  
pp. 1965 ◽  
Author(s):  
Skoczko ◽  
Szatyłowicz

The aim of the study was the assessment of corrosivity and aggressiveness for boiler feed water. The negative effects of water corrosivity and aggressiveness may include silting up of the steel water supply system and the destruction of boiler equipment touched or washed by such water. They may cause the whole industrial production system to fail or be destroyed. That is why it was important to reach a high water purification level, including the calculation of water aggressiveness and corrosivity indicators. The carried out test showed that the simple system used before the modernization of the industrial water treatment plant is not sufficient to reach clean and stable water. The authors proposed modernization, including additional processes to improve boiler water quality, and designed new devices for water treatment. As a result of the new idea, groundwater taken as raw water was treated in individual and complex processes, such as pre-aeration, filtration, ion exchange (cation and anion exchange resigns), extra aeration, and extra degassing. The conducted research included chemical analyses of raw and treated water. In the conducted studies, the indirect method of water aggressiveness and corrosivity assessment was applied using mathematical calculation of the Langelier Saturation Index (LSI), the Ryznar Stability Index (RI), the Larson–Skold Index (LI), and the Singley Index (SI). The results proved that the new proposed processes for the boiler feed water treatment station allow reaching a high water quality and low level of water aggressiveness and corrosion.



2018 ◽  
Vol 10 (11) ◽  
pp. 4239 ◽  
Author(s):  
Marina Valentukevičienė ◽  
Lina Bagdžiūnaitė-Litvinaitienė ◽  
Viktoras Chadyšas ◽  
Andrius Litvinaitis

The trans-boundary area between the Europe Union and other countries is highly susceptible to changes in water quality and variations in the potential pollution load that could influence its eco-systems significantly. The Neris (Viliya) River is one of the biggest surface water bodies in Lithuania and Belarus with an ecologically important area protected by international legislation. The study was aimed at evaluating the impacts of integrated pollution on water quality of the Neris River taking into account different storm-water flows and ecological scenarios. For this purpose, qualitative and quantitative statistical evaluation was set up and calculation was done; different integrated pollution loads of the catchment area were estimated. The evaluation considered a decrease in river discharge due to changes in the regional storm-water flow and technological development that should lead to the growing covered surface and a reduction in the untreated storm-water flows. The obtained results indicated that, in the case of storm-water treatment, the total nitrate and phosphate concentrations will decrease, while in the cases of changes in combined suspended solid, the concentration of nutrients will decrease. Thus, a trans-boundary storm-water treatment plant of the Viliya River is required as it should eliminate pollution accumulation and restore its acceptable environmental status. A coordinated international project for the entire catchment of the Neris (Viliya) River based on the specifications and requirements of the EU Water Framework Directive (EU 2000) should be developed and implemented. Subsequently, ecological river-use policies should be established at the international level, which should offer considerable perspectives for the sustainable development of the area.



2018 ◽  
Vol 1 (1) ◽  
Author(s):  
Benjamin Buysschaert ◽  
Lotte Vermijs ◽  
Agathi Naka ◽  
Nico Boon ◽  
Bart De Gusseme


Sign in / Sign up

Export Citation Format

Share Document