Assessment of prescribability and switchability by using multiple bioequivalence assessment approaches

2021 ◽  
Vol 14 ◽  
Author(s):  
Francis Micheal ◽  
Mohanlal Sayana ◽  
Rajendra Prasad ◽  
Balamurali Musuvathi Motiala

Background: In the drug development process, an assessment of bioequivalence is an integral part. For the evaluation of generics against the comparator, average bioequivalence approach is the gold standard method. In the recent past, there were many discussions on whether we have the adequate tool to evaluate generics and thereby drug interchangeability (prescribability and switchability) issue is addressed as average bioequivalence approach just considers population mean. Hence, the alternative approaches like population bioequivalence and individual bioequivalence assessment approaches arise as different variances like inter/ intra-subject variance and subject-by-formulation variance along with population mean are considered. Objectives: Methoxsalen, in combination with long-wave UVA radiation, is used in the symptomatic management certain psoriasis. The study was aimed to establish the bioequivalence (BE) of a newly developed methoxsalen capsule (MTX test) with that of a reference methoxsalen capsule (MTX reference) using multiple BE methods (i.e., average [ABE], population [PBE], and individual [IBE]) by utilizing a new LC–MS/MS method. Methods: This is an open-label, randomized, balanced, two-treatment, three-period, three-sequence, crossover, single-dose (20 mg, 2 × 10 mg capsules), comparative, oral BE study conducted in 52 healthy, adult males under fasting conditions. Along with various pharmacokinetic (PK) parameters ABE, PBE, and IBE were also determined in the single study. Results: : A non-compartmental model best described the concentration–time data of both MTX test and reference. Both the formulations demonstrated nearly similar values of BE parameters (i.e., AUCo–t, AUC0–∞, Cmax, Tmax, and t1/2). For MTX test, the observed Cmax, AUC0–t, and AUC0–∞ were 125.16±81.53 ng/mL, 313.73±260.86 ng h/mL, and 321.25±271.85 ng h/mL, respectively. For MTX reference, the values were 127.63±71.60 ng/mL, 329.11±252.91 ng h/mL, and 335.48±264.54 ng h/mL, respectively. The bioanalytical method was validated over the concentration range 0.100–100.00ng/mL and the coefficient of determination (r2) was ≥ 0.9991. The sensitivity of the method was 0.100 ng/mL with the accuracy and precision values of 115% and 10.54%, respectively. Conclusion: A single dose of MTX test met the ABE criteria of 80.00% –125.00% for Cmax, AUCo–t, and AUC0–∞, against MTX reference. The study outcome by PBE and IBE approaches proved that MTX Test was bio-inequivalent to MTX reference. Using multiple BE assessment methods in a single BE study is a novel approach and may overcome shortcomings of conventional bioequivalence assessment methods.

2020 ◽  
Vol 21 (2) ◽  
pp. 112-125
Author(s):  
Francis Micheal ◽  
Mohanlal Sayana ◽  
Rajendra Prasad ◽  
Balamurali Musuvathi Motilal

Background: Bioequivalence studies are a vital part of drug development. The average bioequivalence approach is the standard method of assessment to conclude whether the generic product is bioequivalent to the innovator product. Of late, debates are on whether the average bioequivalence approach adequately addresses drug interchangeability as it considers only population mean for the evaluation especially when highly variable drug products and narrow therapeutic index drugs are dealt with. Hence, the alternative approaches like population bioequivalence and individual bioequivalence assessment approaches emerge as they consider inter/intra-subject variance and subject- by-formulation variance along with population mean. Objectives: The objective of the study was to apply different bioequivalence assessment approaches in a replicate bioequivalence study to evaluate the drug interchangeability. Methods: This was an open-label, single-dose, randomized, balanced, two-treatment, three-period, three-sequence, partial replicate crossover bioequivalence study of omeprazole enteric-coated tablet 20 mg conducted on 48 normal healthy subjects under fed conditions. The plasma concentration of omeprazole was analyzed by a validated bioanalytical method to determine the pharmacokinetic and statistical parameters to assess average bioequivalence, population bioequivalence, and individual bioequivalence. Results: In this study, test formulation was shown to be bio-inequivalent to the reference formulation by average bioequivalence, population bioequivalence, and individual bioequivalence approaches. Conclusion: The outcome of the evaluation clearly states that the bioequivalence outcome of all these approaches are the same. Obviously, it does not mean that these three approaches provide the same outcome though the consideration of variances varies. Certainly, population bioequivalence and individual bioequivalence approach will be more accurate for the assessment of drug interchangeability.


Vaccine ◽  
2021 ◽  
Vol 39 (19) ◽  
pp. 2620-2627
Author(s):  
Seuk Keun Choi ◽  
Yeong Ok Baik ◽  
Chan Wha Kim ◽  
Soo Kyung Kim ◽  
Il Nam Oh ◽  
...  

2020 ◽  
Vol 36 (1) ◽  
pp. 111-120 ◽  
Author(s):  
Sunil Bhandari ◽  
Philip A Kalra ◽  
Mario Berkowitz ◽  
Diogo Belo ◽  
Lars L Thomsen ◽  
...  

Abstract Background The optimal intravenous (IV) iron would allow safe correction of iron deficiency at a single infusion over a short time. The FERWON-NEPHRO trial evaluated the safety and efficacy of iron isomaltoside 1000/ferric derisomaltose (IIM) in patients with non-dialysis-dependent chronic kidney disease and iron deficiency anaemia. Methods In this randomized, open-label and multi-centre trial conducted in the USA, patients were randomized 2:1 to a single dose of 1000 mg IIM or iron sucrose (IS) administered as 200 mg IV injections up to five times within a 2-week period. The co-primary endpoints were serious or severe hypersensitivity reactions and change in haemoglobin (Hb) from baseline to Week 8. Secondary endpoints included incidence of composite cardiovascular adverse events (AEs). Results A total of 1538 patients were enrolled (mean estimated glomerular filtration rate 35.5 mL/min/1.73 m2). The co-primary safety objective was met based on no significant difference in the incidence of serious or severe hypersensitivity reactions in the IIM and IS groups [0.3% versus 0%; risk difference: 0.29% (95% confidence interval: –0.19; 0.77; P > 0.05)]. Incidence of composite cardiovascular AEs was significantly lower in the IIM versus IS group (4.1% versus 6.9%; P = 0.025). Compared with IS, IIM led to a more pronounced increase in Hb during the first 4 weeks (P ≤ 0.021), and change in Hb to Week 8 showed non-inferiority, confirming that the co-primary efficacy objective was met. Conclusions Compared with multiple doses of IS, a single dose of IIM induced a non-inferior 8-week haematological response, comparably low rates of hypersensitivity reactions, and a significantly lower incidence of composite cardiovascular AEs.


Sign in / Sign up

Export Citation Format

Share Document