scholarly journals Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography

2017 ◽  
Vol 11 (1) ◽  
pp. 71-78 ◽  
Author(s):  
Iussif Mamede-Neto ◽  
Alvaro Henrique Borges ◽  
Orlando Aguirre Guedes ◽  
Durvalino de Oliveira ◽  
Fábio Luis Miranda Pedro ◽  
...  

Introduction: The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. Methods: One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%. Results: ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05). Conclusion: Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.

2021 ◽  
Vol 6 (2) ◽  
pp. 101-105
Author(s):  
Kadam Krutika Kiran ◽  
Vagarali Hemant ◽  
Pujar Madhu A ◽  
Tamase Aishwarya S ◽  
Sahana Umesh

This study aimed to compare the canal transportation and canal centering ability in the preparation of curved root canals after instrumentation with TruNatomy (TN) (TN; Dentsply Sirona, Maillefer, Ballaigues, Switzerland) and ProTaper Gold (PG) (PG; Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA) files using cone‑beam computed tomography (CBCT). 30 Single rooted extracted human teeth with root curvature ranging from 20-30° according to Schneider’s method were selected. Teeth with any visible cracks or fractures, calcifications, previous root canal treatments were excluded. The teeth were randomly assigned into two groups i.e. Group 1-TN and Group 2-PG (n = 15 each). The teeth were instrumented according to manufacturer’s guidelines for both the groups. Canals were scanned using a CBCT scanner before and after preparation to evaluate the transportation and centering ratio at 3 mm, 5 mm, and 7 mm from the apex. The data analysis was done using SPSS software and the test used was independent sample t test for comparison between the 2 groups.Data obtained suggested that TN group presented lesser canal transportation at the middle third of the root. The PG group showed better centering abitily at apical third of the root canal when both the groups were compared. TN resulted in less transportation than PG at the middle third, and PG showed better centering ability at the apical third. Overall, both systems safely prepared root canals, causing minimal errors.


2021 ◽  
Vol 11 (14) ◽  
pp. 6599
Author(s):  
Khoa Van Pham

The aim of the present study is to compare cone beam computed tomography and periapical digital radiography for the evaluation of root canal preparation. Nine extracted human molars were used in this study. Following access cavity preparation, mesio-buccal roots of maxillary and mesial roots of mandibular molars were prepared and the remaining roots were cut off. Three amalgam cavities were prepared on the coronal part of the teeth and were filled with amalgam to be used as landmarks. Specimens were scanned using cone-beam computed tomography and periapical digital radiograph images were obtained before and after root canal preparation. WaveOne Gold Primary was used for root canal preparation to full working length. Specimens were then scanned using CBCT and a periapical radiograph for the after-instrumentation images. The transportation and centering ratio were measured and calculated on the CBCT and periapical radiographic images. The Bland–Altman method was used for detecting the bias in the evaluation of agreement between the two methods’ measurements. There was agreement between the two methods’ measurements using CBCT scans and periapical digital radiographic images in the evaluation of transportation and centering ratio parameters. The two methods could be used interchangeably in measurements of transportation and calculating the centering ratio.


2018 ◽  
Vol 12 (1) ◽  
pp. 32-45 ◽  
Author(s):  
Iussif Mamede-Neto ◽  
Álvaro Henrique Borges ◽  
Ana Helena Gonçalves Alencar ◽  
Marco Antonio Hungaro Duarte ◽  
Manoel Damião Sousa Neto ◽  
...  

Objective: To evaluate transportation (T) and centering ability (CA) of root canal preparations using continuous or reciprocating nickel-titanium endodontic files. Materials and Methods: Ninety-six mesiobuccal root canals of mandibular first and second molars were randomly divided into 6 groups (n=16) according to the rotary file used: 1. ProTaper Next; 2. ProTaper Gold; 3. Mtwo; 4. BioRaCe; 5. WaveOne Gold; 6. Reciproc. Root canals were prepared according to manufacturer’s instructions. Cone beam computed tomography scans were obtained before and after root canal preparation. Measurements were made at six different reference points: 2, 3 and 4 mm from the apex and 2, 3 and 4 mm below furcation in different directions. Results: The greatest Mesiodistal (MD) Transportation (T) was found for Reciproc files (p<0.05), and the greatest buccolingual (BL) T, for Reciproc, ProTaper Gold and ProTaper Next files (p<0.05). The greatest Mesiodistal (MD) Centering Ability (CA) was found for BioRaCe files (p<0.05), and the greatest Buccolingual (BL) CA, for BioRaCe and Mtwo files (p<0.05). Conclusion: All systems produced root canal transportation. No file system achieved perfect CA of root preparation. Reciproc files had the greatest MD T and BL T. BioRaCe files had the greatest MD CA, whereas BL CA was similar for BioRaCe and Mtwo files.


2015 ◽  
Vol 16 (11) ◽  
pp. 869-872 ◽  
Author(s):  
Suhashini Ramanathan ◽  
Pradeep Solete

ABSTRACT Aim To evaluate the remaining dentin thickness of teeth after cleaning and shaping the root canal using three rotary instrumentation technique using cone-beam computed tomography (CBCT). Materials and methods This in vitro study is being done with 30 premolar samples with 20’ curvature. The study is divided into three groups a CBCT was taken to measure the shortest distance from the root canal outline to the closest adjacent root surface was measured at each level from the cementoenamel junction (CEJ) (1,3, 5 and 7 mm) before and after root canal instrumentation. The purpose of this study was to compare the effects of different instruments used to prepare curved root canals on the remaining cervical dentin thickness and total amount of dentin removed from root canals during instrumentation by using multi-slice CBCT. The remaining dentin thickness is very much necessary for the success rate of root canal treatment. However, this study helps to prove that a conservative preparation with a sound remaining dentin thickness is much more advisable. Result It was observed that there was a significant difference at 1 and 3 mm (p < 0.05) and at 5 and 7 mm there was no significant difference (p > 0.05). Mtwo has removed less amount dentin when compared to ProTaper Universal and ProTaper Next system at 1 and 3 mm. Conclusion Under the conditions of the study, we concluded that ProTaper Universal and ProTaper Next should be used judiciously, as it causes higher thinning of root dentin of the root when compared with Mtwo. How to cite this article Ramanathan S, Solete P. Cone-beam Computed Tomography Evaluation of Root Canal Preparation using Various Rotary Instruments: An in vitro Study. J Contemp Dent Pract 2015;16(11):869-872.


2017 ◽  
Vol 43 (6) ◽  
pp. 1014-1017 ◽  
Author(s):  
Thiago Oliveira Sousa ◽  
Bassam Hassan ◽  
Hesam Mirmohammadi ◽  
Hagay Shemesh ◽  
Francisco Haiter-Neto

2014 ◽  
Vol 15 (2) ◽  
pp. 174-180 ◽  
Author(s):  
Dina Al-Sudani ◽  
Majed Almalki ◽  
Saad Al-Shahrani ◽  
Michael Ahlquist

ABSTRACT Aim The present study was conducted with the aim of evaluating and comparing the shaping ability of two Nickel-titanium rotary instruments, with two disparate design features, on root canal geometry of extracted human maxillary first premolars using microcomputed tomography. Study design Twenty four bifurcated maxillary first premolars were divided into two groups and embedded in a rubber-based impression material. Both groups were submitted to microcomputed tomography before and after canal preparation (buccal and palatal) with either ProFile Vortex or Revo-S rotary instruments. Images were reconstructed and cross-sections corresponding to a distance 1, 2, 3, 4, 5, 6, and 7 mm from the anatomical apex were selected for canal transportation analysis. Volume changes were also measured. Results The degree and direction of canal transportation were non-significant for both instruments. Statistically significant differences were observed only between levels in the buccal canal in both groups. There was no significant difference between the two rotary systems in regards to the volume of dentin removed. Conclusion Our findings showed that ProFile Vortex and Revo-S instruments respected the original root canal anatomy and behaved similarly. ProFile Vortex rotary systems produced with innovative process were concluded to shape the upper maxillary premolar by leading minimal canal transportation, similar to Revo-S, rotary systems produced from traditional process. How to cite this article Al-Sudani D, Almalki M, Al-Shahrani S, Ahlquist M. Geometric Analysis of Maxillary First Premolar Prepared by Two Nickel-Titanium Rotary Instruments. J Contemp Dent Pract 2014;15(2):174-180.


2018 ◽  
Vol 6 (02/03) ◽  
pp. 076-079
Author(s):  
Aditi Soni ◽  
Anjali Oak

Abstract Aim The aim of this study was to compare the canal transportation and canal centric ability of One Shape (Micro Mega, Besançon, France) and Mani Silk (Mani Utsunomiya, Tochigi, Japan) nickel-titanium (NiTi) rotary files in curved canals with the help of cone beam computed tomography (CBCT). Materials and Methods Total 40 mesiobuccal canals of maxillary molars with an angle of curvature ranging between 25 and 45 degrees were divided according to the instrument used in canal preparation into two groups 20 samples each: One Shape (group 1) and Mani Silk (group 2). Pre- and post-instrumentation scans were performed using CBCT (Carestream CS 9300 scanner) to evaluate the transportation and centric ability at apical, middle, and coronal levels using unpaired Student's t-test. Results Mani Silk file showed significantly less canal transportation and better canal centric ability compared to One Shape system. Conclusion Mani Silk file maintained original canal curvature better than One Shape NiTi rotary file.


Sign in / Sign up

Export Citation Format

Share Document