scholarly journals Study of Thermal Neutron Flux and Generated Energy from Linac using CR-39 Detector in Liquid Medium

Natural-B ◽  
2018 ◽  
Vol 004 (03) ◽  
pp. 145-152
Author(s):  
Kurnia Nur Widyanti ◽  
Chomsin S. Widodo ◽  
Bunawas Bunawas
Natural-B ◽  
2018 ◽  
Vol 004 (03) ◽  
pp. 145-152
Author(s):  
Kurnia Nur Widyanti ◽  
Chomsin S. Widodo ◽  
Bunawas Bunawas

1993 ◽  
Vol 11 (3) ◽  
pp. 559-566 ◽  
Author(s):  
Y.R. Shaban ◽  
G.H. Miley

A practical, visible nuclear-pumped laser (NPL) has been sought at the University of Illinois and other laboratories for a number of years. Yet, the results from successful visible NPLs to date have not been fully satisfactory, e.g., the threshold pumping power is too high for conventional applications. Progress in recent studies of 3He-Ne-H2 as a candidate NPL operating in the visible region at 585.3 nm on the 2P1,-1S2 Ne transition is described. We obtained lasing on the above transition for 3He-Ne-H2 concentrations of 1,140, 588, and 412 torr, respectively, with the laser cavity placed in the beamport of the University of Illinois TRIGA reactor. The threshold thermal neutron flux is 1014 n/cm2-s, corresponding to a threshold pumping power of 5 W/cm3.


Author(s):  
Suzanne Nowicki ◽  
Stephen Wender ◽  
Aaron Couture ◽  
Laura Dominik ◽  
Adam Warniment ◽  
...  

2021 ◽  
Vol 10 (1) ◽  
pp. 11-20
Author(s):  
Tho Nguyen Thi ◽  
Anh Tran Tuan ◽  
Cuong Trinh Van ◽  
Doanh Ho Van ◽  
Duong Tran Quoc ◽  
...  

The accuracy of elements concentration determination using the k0-standardization method directly depends on irradiation and measurement parameters including Non-1/E epithermal neutron flux distribution shape α (ϕ epi ≈1/E1+α ) , thermal-to-epithermal neutron flux ratio f, efficiency ε, peak area… In the case of the irradiation position at the rotary rack of the Dalat Nuclear Research Reactor (DNRR), the difference of thermal neutron flux between the bottom (3.54x1012 n.cm-2.s-1) and the top (1.93x1012 n.cm-2.s-1) of the 15 cm aluminum container is up to 45%. Therefore, it is necessary to accurately determine above-mentioned parameters in the sample irradiation position. The present paper deals with the determination of the distribution of thermal neutron flux along the sample irradiation container by using 0.1% Au–Al wire activation technique. The thermal neutron flux was then used to calculate the concentration of elements in the Standard Reference Material 2711a and SMELS type III using k0-INAA method at different positions in the container. The obtained results with the neutron flux correction were found to be in good agreement with the certified values. In conclusion, the proposed technique can be applied for activation analyses without sandwiching flux monitors between samples during irradiations.


Sign in / Sign up

Export Citation Format

Share Document