scholarly journals Evaluation of Denture Functions in Complete Denture Wearers by Using Electromyography and Pressure Distribution Measuring System.

1991 ◽  
Vol 35 (4) ◽  
pp. 804-816
Author(s):  
Toshio Hosoi ◽  
Yoshikazu Ishikawa ◽  
Tsutomu Okajima ◽  
Takashi Sagae ◽  
Ryuichi Masuo ◽  
...  
2013 ◽  
Vol 281 ◽  
pp. 329-334
Author(s):  
Jun He ◽  
Huang Ping ◽  
Qian Qian Yang

In the present paper, a new method for measuring elastohydrodynamic lubrication (EHL) pressure in line contact is proposed, which is based on the photoelastic technique. The pressure distribution of EHL film and the inner stresses in the friction pairs are fundamental issues to carry out EHL research. The film thickness, pressure and temperature have been successfully obtained with solving the basic equations such as Reynolds equation and energy equation simultaneously or separately, with numerical model of EHL problem. The film thickness can be also measured with the optical interference technique. However, the pressure measurement is still a problem which has not been well solved yet, so as the inner stresses inside the friction pairs. With the experimental mechanics, the photoelastic technique is a possible method to be used for measuring the pressure distribution of EHL film and inner friction pair in the line contact. Therefore, A flat plastic disk and a steel roller compose the frictional pairs of the photoelastic pressure measuring rig with combining the monochromatic LED light source, polarizer CCD camera and stereomicroscope to form the whole pressure measuring system of the line contact EHL. The experimental results with the rig display the typical features of EHL pressure. This shows that the method is feasible to be used for measuring the pressure of EHL film and the inner stresses of the friction pairs in the line contact.


2012 ◽  
Vol 79 ◽  
pp. 94-99 ◽  
Author(s):  
Ewa Klimiec ◽  
Wiesław Zaraska ◽  
Jacek Piekarski ◽  
Barbara Jasiewicz

The paper presents a dynamic measurement method of the distribution of foot pressure exerted on the ground by a four-point shoe insole, developed by authors, which can be placed in any sport footwear. The value of pressure was measured on the heel, medial midfoot, metatarsal, and great toe by recording values of a generated voltage by sensors which were made of piezoelectric polymer PVDF film 110 µm thick with printed silver electrodes. As confirmed by scanning microscope studies, the foil applied in the sensors is semi-crystalline. The shoe measurement insert consists of two polyester films without piezoelectric properties between them, electroactive polymer sensors were placed. The films were glued together. To match the measuring circuit to the sensors used, two circuits were tested, a voltage measuring circuit with an input resistance of above 1012 Ω (open circuit), and a charge measuring circuit (shorted circuit). The charge measuring circuits with the RC high-pass filter, which attenuates the slow-changing pyroelectric signal was selected as it ensures the desired measurement accuracy. As presented in the paper, as PVDF sensors are very sensitive to any mechanical deformation, it is important to properly design the shoe insole to ensure its correct use during pressure distribution measurements. The measuring system developed by the authors, allows testing of foot pathology for any length of time in a dynamic way.


Sign in / Sign up

Export Citation Format

Share Document