scholarly journals The Generalizability of a Medication Administration Discrepancy Detection System: Quantitative Comparative Analysis (Preprint)

2020 ◽  
Author(s):  
Eric Kirkendall ◽  
Hannah Huth ◽  
Benjamin Rauenbuehler ◽  
Adam Moses ◽  
Kristin Melton ◽  
...  

BACKGROUND As a result of the overwhelming proportion of medication errors occurring each year, there has been an increased focus on developing medication error prevention strategies. Recent advances in electronic health record (EHR) technologies allow institutions the opportunity to identify medication administration error events in real time through computerized algorithms. MED.Safe, a software package comprising medication discrepancy detection algorithms, was developed to meet this need by performing an automated comparison of medication orders to medication administration records (MARs). In order to demonstrate generalizability in other care settings, software such as this must be tested and validated in settings distinct from the development site. OBJECTIVE The purpose of this study is to determine the portability and generalizability of the MED.Safe software at a second site by assessing the performance and fit of the algorithms through comparison of discrepancy rates and other metrics across institutions. METHODS The MED.Safe software package was executed on medication use data from the implementation site to generate prescribing ratios and discrepancy rates. A retrospective analysis of medication prescribing and documentation patterns was then performed on the results and compared to those from the development site to determine the algorithmic performance and fit. Variance in performance from the development site was further explored and characterized. RESULTS Compared to the development site, the implementation site had lower audit/order ratios and higher MAR/(order + audit) ratios. The discrepancy rates on the implementation site were consistently higher than those from the development site. Three drivers for the higher discrepancy rates were alternative clinical workflow using orders with dosing ranges; a data extract, transfer, and load issue causing modified order data to overwrite original order values in the EHRs; and delayed EHR documentation of verbal orders. Opportunities for improvement were identified and applied using a software update, which decreased false-positive discrepancies and improved overall fit. CONCLUSIONS The execution of MED.Safe at a second site was feasible and effective in the detection of medication administration discrepancies. A comparison of medication ordering, administration, and discrepancy rates identified areas where MED.Safe could be improved through customization. One modification of MED.Safe through deployment of a software update improved the overall algorithmic fit at the implementation site. More flexible customizations to accommodate different clinical practice patterns could improve MED.Safe’s fit at new sites.

10.2196/22031 ◽  
2020 ◽  
Vol 8 (12) ◽  
pp. e22031
Author(s):  
Eric Kirkendall ◽  
Hannah Huth ◽  
Benjamin Rauenbuehler ◽  
Adam Moses ◽  
Kristin Melton ◽  
...  

Background As a result of the overwhelming proportion of medication errors occurring each year, there has been an increased focus on developing medication error prevention strategies. Recent advances in electronic health record (EHR) technologies allow institutions the opportunity to identify medication administration error events in real time through computerized algorithms. MED.Safe, a software package comprising medication discrepancy detection algorithms, was developed to meet this need by performing an automated comparison of medication orders to medication administration records (MARs). In order to demonstrate generalizability in other care settings, software such as this must be tested and validated in settings distinct from the development site. Objective The purpose of this study is to determine the portability and generalizability of the MED.Safe software at a second site by assessing the performance and fit of the algorithms through comparison of discrepancy rates and other metrics across institutions. Methods The MED.Safe software package was executed on medication use data from the implementation site to generate prescribing ratios and discrepancy rates. A retrospective analysis of medication prescribing and documentation patterns was then performed on the results and compared to those from the development site to determine the algorithmic performance and fit. Variance in performance from the development site was further explored and characterized. Results Compared to the development site, the implementation site had lower audit/order ratios and higher MAR/(order + audit) ratios. The discrepancy rates on the implementation site were consistently higher than those from the development site. Three drivers for the higher discrepancy rates were alternative clinical workflow using orders with dosing ranges; a data extract, transfer, and load issue causing modified order data to overwrite original order values in the EHRs; and delayed EHR documentation of verbal orders. Opportunities for improvement were identified and applied using a software update, which decreased false-positive discrepancies and improved overall fit. Conclusions The execution of MED.Safe at a second site was feasible and effective in the detection of medication administration discrepancies. A comparison of medication ordering, administration, and discrepancy rates identified areas where MED.Safe could be improved through customization. One modification of MED.Safe through deployment of a software update improved the overall algorithmic fit at the implementation site. More flexible customizations to accommodate different clinical practice patterns could improve MED.Safe’s fit at new sites.


2020 ◽  
Author(s):  
Bintang Marsondang Rambe

Latar Belakang Keselamatan pasien (patient safety) rumah sakit adalah suatu sistem dimana rumah sakit membuat asuhan pasien lebih aman yang meliputi assessment risiko, identifikasi dan pengelolaan hal yang berhubungan dengan risiko pasien, pelaporan dan analisis insiden, kemampuan belajar dari insiden dan tindak lanjutnya serta implementasi solusi untuk meminimalkan timbulnya risiko dan mencegah terjadinya cedera yang disebabkan oleh kesalahan akibat melaksanakan suatu tindakan atau tidak mengambil tindakan yang seharusnya diambil yang dilakukan oleh perawat (Kemenkes, 2011).Salah satu kesalahan yang dapat merugikan pasien adalah medication error. Menurut WHO (2016) medication error adalah setiap kejadian yang dapat dicegah yang menyebabkan penggunaan obat yang tidak tepat yang menyebabkan bahaya kepasien, dimana obat berada dalam kendali profesional perawatan kesehatan. proses terjadi medication error dimulai dari tahap prescribing, transcribing, dispensing,dan administration. Kesalahan peresepan (prescribing error), kesalahan penerjemahan resep (transcribing erorr), kesalahan menyiapkan dan meracik obat (dispensing erorr), dan kesalahan penyerahan obat kepada pasien (administration error). Medication error yang paling sering terjadi adalah pada fase administration / pemberian obat yang dilakukan oleh perawat.Administration error terjadi ketika pemberian obat kepada pasien tidak sesuai dengan prinsip enam benar yaitu benar obat, benar pasien, benar dosis, benar rute pemberian, benar waktu pemberian dan benar pendokumentasian. Secara global, kesalahan pemberian obat (medication errors) sampai saat ini masih menjadi isu keselamatan pasien dan kualitas pelayanan di beberapa rumah sakit (Depkes RI, 2015; AHRQ, 2015). Perawat sebagai bagian terbesar dari tenaga kesehatan di rumah sakit, mempunyai peranan dalam kejadian medication error. Perawat berkontribusi karena perawat banyak berperan dalam proses pemberian obat. Pemberian obat/ Medication Administration adalah salah satu intervensi keperawatan yang paling banyak dilakukan, dengan sekitar 5- 20% waktu perawat dialokasikan untuk kegiatan ini (Härkänen et al.,, 2019). Pemberian obat juga mencakup tugas-tugas lain, seperti menyiapkan dan memeriksa obat obatan, memantau efek obat-obatan, mengedukasi pasien tentang pengobatan, dan memperdalam pengetahuan perawat tentang obat – obatan sendiri (DrachZahavy et al., 2014 dalam Yulianti et al., 2019)Berdasarkan isu tersebut, penulis tertarik untuk melakukan literature review terkait faktor perawat dalam pelaksanakan keselamatan pasien terhadap kejadian medication administration error di Rumah Sakit.


2020 ◽  
Vol 27 (3) ◽  
pp. e100170
Author(s):  
Johanna I Westbrook ◽  
Neroli S Sunderland ◽  
Amanda Woods ◽  
Magda Z Raban ◽  
Peter Gates ◽  
...  

BackgroundElectronic medication systems (EMS) have been highly effective in reducing prescribing errors, but little research has investigated their effects on medication administration errors (MAEs).ObjectiveTo assess changes in MAE rates and types associated with EMS implementation.MethodsThis was a controlled before and after study (three intervention and three control wards) at two adult teaching hospitals. Intervention wards used an EMS with no bar-coding. Independent, trained observers shadowed nurses and recorded medications administered and compliance with 10 safety procedures. Observational data were compared against medication charts to identify errors (eg, wrong dose). Potential error severity was classified on a 5-point scale, with those scoring ≥3 identified as serious. Changes in MAE rates preintervention and postintervention by study group, accounting for differences at baseline, were calculated.Results7451 administrations were observed (4176 pre-EMS and 3275 post-EMS). At baseline, 30.2% of administrations contained ≥1 MAE, with wrong intravenous rate, timing, volume and dose the most frequent. Post-EMS, MAEs decreased on intervention wards relative to control wards by 4.2 errors per 100 administrations (95% CI 0.2 to 8.3; p=0.04). Wrong timing errors alone decreased by 3.4 per 100 administrations (95% CI 0.01 to 6.7; p<0.05). EMS use was associated with an absolute decline in potentially serious MAEs by 2.4% (95% CI 0.8 to 3.9; p=0.003), a 56% reduction in the proportion of potentially serious MAEs. At baseline, 74.1% of administrations were non-compliant with ≥1 of 10 procedures and this rate did not significantly improve post-EMS.ConclusionsImplementation of EMS was associated with a modest, but significant, reduction in overall MAE rate, but halved the proportion of MAEs rated as potentially serious.


2001 ◽  
Vol 16 (4) ◽  
pp. 128-134 ◽  
Author(s):  
Bonnie J. Wakefield ◽  
Mary A. Blegen ◽  
Tanya Uden-Holman ◽  
Thomas Vaughn ◽  
Elizabeth Chrischilles ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document