scholarly journals SIMULTANEOUS DETERMINATION OF CADMIUM, COPPER AND LEAD IN SEA WATER BY ADSORPTIVE STRIPPING VOLTAMMETRY IN THE PRESENCE OF CALCON AS A COMPLEXING AGENT

2013 ◽  
Vol 13 (3) ◽  
pp. 236-241 ◽  
Author(s):  
Deswati Deswati ◽  
Hamzar Suyani ◽  
Safni Safni ◽  
Umiati Loekman ◽  
Hilfi Pardi

A selective and sensitive adsorptive stripping voltammetric (AdSV) procedure for the simultaneous determination of cadmium, copper and lead in the sea water was conducted. The aim of this research is to get optimum condition for simultaneous determination of cadmium, copper and lead. Adsorptive stripping voltammetry has been used for determination of trace amount of Cd(II), Cu(II) and Pb (II) by using calcon as a complexing agent. The parameters studied were variation of calcon concentration, pH, accumulation potential and accumulation time. In this study, the optimum conditions were calcon concentration of 0.6 mM, pH = 4.0, accumulation potential of -0.7 V and accumulation time of 80 sec. At the optimum conditions, the relative standard deviation were 8.78%, 3.12%, and 4.02% for Cd(II), Cu(II) and Pb(II) respectively for eight replicates (n = 8) measurements of 10 μg/L mixed standard solution of Cd(II), Cu(II) and Pb(II). The method was applied to the direct simultaneous determination of Cd(II), Cu(II) and Pb(II) in sea water around Bungus, Padang City. Concentration of Cd(II), Cu(II) and Pb(II) in samples were equal to 1.8 μg/L for Cd(II), 38.6 μg/L for Cu(II) and 0.7 μg/L for Pb(II) with recovery of 87.03%, 98.80%, and 95.73%, respectively.

2015 ◽  
Vol 3 (1) ◽  
pp. 22
Author(s):  
Deswati ◽  
Hamzar Suryani ◽  
Imelda ◽  
Yulia

 ABSTRACT Study of optimation chromium (VI) in sea water by adsorptive stripping voltammetry has been done. The aim of this method to get optimum conditions for determination of Cr(VI). Adsorptive stripping voltammetry (AdSV) has been used for the ultra trace determination of chromium using 2,2’- bipyridin as ligand. Parameters were done, like accumulation time, concentration of ligand, pH, accumulation potential, electrolyte concentration and catalyst concentration. In this case, the optimum conditions were reached in accumulation time 80 second, pH 5.0, concentration of 2,2’- bipyridin 10 μM, accumulation potential -0,6 Volt and electrolyte concentration (NH4Cl) 0,1 M. In the optimum conditions, a linear calibration graph was obtained with correlation coefficient of 0.9971, the relative standard deviation was 15.06 % for eight replicates (n = 8) measurements of 10 μg/L of Cr(VI). The detection limit method was 0.1692 μg/L. The method was applied to the direct determination of Cr(VI) in sea water around Muara Padang water. Concentration Cr(VI) in sample was equal to 0.9684 μg/L with recovery of 90.23 %. Keywords : optimation, chromium, adsorptive, stripping, voltammetry


2012 ◽  
Vol 5 (2) ◽  
pp. 100
Author(s):  
Deswati ◽  
Hamzar Suyani ◽  
Umiati Loekman ◽  
Nilam Sari

A selective and sensitive adsorptive stripping voltammetric (AdSV) method for simultaneous determination of lead(II) and cadmium(II) were proposed. The aim of this study was to get the optimum condition for simultaneuos determination of lead(II) and cadmium(II). The parameters were studied such as: variation of accumulation potential, accumulation time, pH, and variation ofcalcon concentration. In this case, the optimum conditions were reached at accumulation potential –0.7 V, accumulation time 80 s, concentration of 0.12 mM calcon, and pH 7.0. At the optimumconditions the relative standard deviation were 2.90% and 1.46% for Pb(II) and Cd(II) respectively for eight replicates (n = 8) measurements. The method was applied for the direct determination of Pb(II) and Cd(II) in sea water around Bungus, Padang City. Concentration Pb(II) and Cd(II) insample were 9.918 μg/L – 27.320 μg/L for Pb(II) and 7.997 μg/L - 32.521 μg/L for Cd(II), with recovery of 99.48%, and 103.28 for Pb(II), and Cd(II) respectively.


2015 ◽  
Vol 4 (2) ◽  
pp. 55
Author(s):  
Deswati ◽  
Hamzar Suyani ◽  
Bustanul Arifin ◽  
Imelda ◽  
Yunita Salamah

 ABSTRACT The research about determination of Cu(II) by adsorptive stripping voltammetry (AdSV) was conducted. AdSV method was applied to the determination of copper in ultra trace concentration. The parameters of ligand, accumulation potential, accumulation time, pH and ligand concentration was studied. Calcon was found as complexing agent that give the highest peak current. The optimum condition are accumulation potential -0,7 V, accumulation time 60 s, pH 10, and calcon concentration 0.12 mM. The relative standar deviation (n=8) at 10 µg/L standard concentration were obtained 4,27 %. This method was applied to determination of Cu(II) in sample from Batang Air Dingin, Lubuk Minturun and Muara Padang. The sample concentration were 4,778 µg/L and 5,189 µg/L for Batang Air Dingin and Muara Padang, respectively. The recovery of this method was studied for sample from Muara Padang and 98,31 % was obtained. Key words :   Adsorptive, Stripping, Voltammetry, Calcon and Copper    


2015 ◽  
Vol 3 (2) ◽  
pp. 122
Author(s):  
Deswati Deswati ◽  
Hamzar Suyani ◽  
Citra Buhatika

  ABSTRACT Study of optimation cadmium(II) by adsorptive stripping voltammetry has been done. The aim of this study to get optimum conditions for determination of Cd(II). Parameters were done : potential accumulation, time accumulation, pH, supporting electrolite concentration and optimum of complex concentration. In this case, the optimum conditions were reached in potential accumulation -0.7 V, time accumulation 60 second, pH 7.0, NH4Cl 0.12 M, calcon concentration 0.12 mM. In the optimum condition was obtained with the relative standard deviation was 4.61% for eight replicates, measurements of 0.01 ppm. The method was applied to the direct determination of Cd(II) in water around Batang Air Dingin Lubuk Minturun and Muara Padang. Concentration Cd(II) in sample was equal to 7.359 μg/L and 3.659 μg/L with recovery of 99.04%. Keywords: cadmiun, adsorptive, stripping, voltammetry


2013 ◽  
Vol 69 (2) ◽  
pp. 438-442 ◽  
Author(s):  
Shahryar Abbasi ◽  
Abbas Farmany ◽  
Mahmoud Roushani ◽  
Seyede Shima Mortazavi

A simple and sensitive adsorptive stripping voltammetry method was developed for determination of Zn using N-nitrozo-N-phenylhydroxylamine (cupferron) as a selective complexing agent. This complex absorbed on the hanging mercury drop electrode and created a sensitive peak current. The peak current and concentration of zinc accorded with a linear relationship in the range of 0.85–320 ng mL−1. The influence of pH and the nature of supporting electrolytes, concentration of ligand, preconcentration time and applied potential were investigated. The relative standard deviation at a concentration level of 50 ng mL−1 was 1.8%. The method was applied to the determination of zinc in city, river and mineral water samples, with satisfactory results.


2012 ◽  
Vol 12 (1) ◽  
pp. 20-27 ◽  
Author(s):  
Deswati Deswati ◽  
Hamzar Suyani ◽  
Safni Safni

A sensitive and selective absorptive stripping voltammetric (AdSV) method to determine Cd(II), Cu(II), Pb(II) and Zn(II) in sea water is proposed. The aim of this study was to get optimum condition for the determination of Cd(II), Cu(II), Pb(II) and Zn(II). Absorptive stripping voltammetry has been used for ultra trace determination of Cd(II), Cu(II), Pb(II) and Zn(II) using calcon as a complexing agent (ligand). In this case, the optimum conditions were reached at 0.1 M KCl supporting electrolyte, concentration of 0.5 mM calcon for Cd(II), Cu(II) 0.3 mM while 0.7 mM for Pb(II) and Zn(II), pH 6 for Cu(II) and pH 7 for Cd(II), Pb(II) and Zn(II), accumulation potential -0.5 V for Cu(II) and Pb(II) and -0.6 V for Cd(II) and Zn(II) and accumulation time 70 sec for Cd(II), 90 sec for Cu(II) and Pb (II) while 50 s for Zn(II). At the optimum condition the relative standard deviations were 7.80%, 4.25%, 8.70% and 0.86% for Cd(II), Cu(II), Pb(II) and Zn(II) respectively for eight replicates (n = 8) measurements of 10 μg/L Cd(II), Cu(II), Pb(II) and Zn(II). The method was applied for the direct determination of Cd(II), Cu(II), Pb(II) and Zn(II) in sea water around Bungus, Padang City. Concentration Cd(II), Cu(II), Pb(II) and Zn(II) in sample were 13.200 μg /L for Cd(II), 17.200 μg/L for Cu(II), 0.089 μg/L for Pb(II) and 62.000 μg/L for Zn(II) with recovery of 98.68%, 97.99%, 96.17% and 99.96% for Cd(II), Cu(II), Pb(II) and Zn(II), respectively.


Chemosensors ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 94
Author(s):  
Víctor Padilla ◽  
Núria Serrano ◽  
José Manuel Díaz-Cruz

A commercial and disposable screen-printed carbon electrode (SPCE) has been proposed for a fast, simple and low-cost determination of Ni(II) at very low concentration levels by differential pulse adsorptive stripping voltammetry (DPAdSV) in the presence of dimethylglyoxime (DMG) as complexing agent. In contrast with previously proposed methods, the Ni(II)-DMG complex adsorbs directly on the screen-printed carbon surface, with no need of mercury, bismuth or antimony coatings. Well-defined stripping peaks and a linear dependence of the peak area on the concentration of Ni(II) was achieved in the range from 1.7 to 150 µg L−1, with a limit of detection of 0.5 µg L−1 using a deposition time of 120 s. An excellent reproducibility and repeatability with 0.3% (n = 3) and 1.5% (n = 15) relative standard deviation, respectively, were obtained. In addition, the suitability of the SPCE as sensing unit has been successfully assessed in a wastewater certificated reference material with remarkable trueness and very good reproducibility.


Sign in / Sign up

Export Citation Format

Share Document