scholarly journals Optimization of Gas Exposure Time for Ethylene Oxide (ETO) Sterilization

Author(s):  
Ravi Vital Kandisa

Advancement in technology made the medical device manufacturing industry prominent among all the industrial sectors. Most health care products and medical devices require sterilization. Due to the heat sensitivity of the medical devices, Ethylene Oxide (ETO) sterilization is recommended but ETO is an expensive and long process. Now, there is a need to find an efficient, minimal cost and a lesser amount of time for sterilization process. In this present study, we developed and validated a minimum time, low cost, and efficient ETO sterilization process that can be used at an Industrial scale.

2017 ◽  
Vol 33 (S1) ◽  
pp. 116-117
Author(s):  
Jana Hemmerling ◽  
Karolin Eberle ◽  
Sara Hogger ◽  
Maike Gupta ◽  
Anna Ullraum ◽  
...  

INTRODUCTION:National Health Technology Assessments (HTAs) for medical devices are crucial to regulate the quality and costs of healthcare systems. However, there is diversity in several aspects among European countries. Consequently, controversial results might arise, generating contrary reimbursement decisions. The European Network for Health Technology Assessment (EUnetHTA) is an interface platform for the harmonization of HTA information across Europe. The European Commission expects national uptake of a European HTA. Thus, European HTAs might overcome the diversity of national HTA requirements.METHODS:We aimed to compare German and European HTAs for medical devices regarding processes, methods, timelines, and involvement of medical device companies. Therefore we analyzed guidelines, requirements, and output of EUnetHTA and compared those aspects with the German G-BA (Federal Joint Committee, Gemeinsamer Bundesausschuss) standard and IQWiG (Institute for Quality and Efficiency in Health Care, Institut für Qualität und Wirtschaftlichkeit im Gesundheitswesen) methods.RESULTS:We found differences between the European and German HTAs for medical devices regarding timelines, involvement of medical device companies, body of evidence, use of surrogate endpoints, and methodology. European HTAs for medical devices reflect the clinical reality by integrating the existing evidence (including real world data) and by using comprehensive statistical methods for medical devices. In contrast, German HTAs for medical device-based technologies are long lasting and are often restricted to a small body of evidence.CONCLUSIONS:As a conclusion, similar to pharmaceuticals, the European HTA framework might also become a worldwide platform for HTAs of medical device-based technologies with the potential to harmonize reimbursement decisions and patients health care across countries on the basis of clinical reality.


2020 ◽  
Author(s):  
Aaron Ceross ◽  
Jeroen Bergmann

UNSTRUCTURED Software-as-a-medical-device (SaMD) has gained popularity as a type of medical device. However, to date, empirical analysis of SaMD trends have been lacking. Using databases managed by the US medical device regulator (the Food and Drug Administration), we map the path SaMD takes towards classification and recorded adverse events. The findings show that while SaMD has been identified in literature as an area of development, the data analysis suggests that this growth has been modest. These devices are overwhelming classified as moderate to high risk and they take a very particular path to that classification. The digital revolution in health care is less pronounced when evidence is considered of SaMD. In general, the trend for software registration mimics that of medical devices.


Sign in / Sign up

Export Citation Format

Share Document