scholarly journals Analysis of Slip Ring Induction Motor Drive Using Slip Power Recovery Scheme with Inverter and Chopper Control for Id Fan in Power Plant

Author(s):  
Manish Kapse

Abstract: Induction motors are used as industrial drive and for various applications in power plant due to their rugged, robust and simple construction as well as low cost. The speed control of SRIM is dexterous by slip power recovery scheme consisting of inverter control, chopper control, and rotor resistance control techniques. This paper presents the boost in the performance characteristics and energy saving of SRIM drive by inverter and buck-boost chopper based slip power recovery scheme (SPRS). The simulation model of a WRIM drive using inverter and based buck-boost chopper control has been executed in the Simulink platform. The simulation results using inverter and chopper control have been studied. The active power and reactive power have been taken as parameter for analyzing the energy saving by the drive. The simulation result has shown that inverter chopper control SPRS large amount of energy saving.

Author(s):  
Nagamani Chandra Sekara ◽  
Somanatham R ◽  
Chaitanya Kumar U

The use of Squirrel Cage for Traction has revolutionised the motive power of a Locomotive. The Asynchronous Motor is rugged with high starting Torque, has a very smooth Voltage and Speed control as compared to a DC Series Motor. When looking at the Traction perspective, a Slip Ring Induction Motor can be an alternative to the Squirrel Cage Motor as it has higher starting Torque and better efficiency than a Squirrel Cage Motor. the Slip Power Recovery scheme also plays a proactive role as ther can be substantial savings of energy in case of a Slip Ring Induction Motor. A detailed design and analysis of a Drive System with Slip Ring Induction Motor for Electric Traction is presented in this Research Paper


Author(s):  
Siamak Farhad ◽  
Maryam Younessi-Sinaki ◽  
M. Saffar-Avval

The purpose of this paper is to show how the ASME performance test codes can be used as a low cost and efficient tool for energy survey in order to reduce fuel and power consumptions in operating steam power plants. In this regard, A 1000 MW steam power plant was selected and many studies were performed to evaluate the possibility and effects of performing such tests on this power plant. The results show that many of the instruments of this plant are suitable for the desired purpose and the tests can be applied for achieving energy saving. Also, the results show that the natural gas and heavy oil fuel consumptions have increased around 10 and 8.3 percent, respectively, relative to the design conditions of this plant and at least half of these increases can be reduced by proper adjustments of control devices and simple repairs.


2011 ◽  
Vol 10 (3) ◽  
pp. 341-347 ◽  
Author(s):  
Maria Harja ◽  
Marinela Barbuta ◽  
Lacramioara Rusu ◽  
Corneliu Munteanu ◽  
Gabriela Buema ◽  
...  

2021 ◽  
Vol 13 (13) ◽  
pp. 7279
Author(s):  
Zbigniew Skibko ◽  
Magdalena Tymińska ◽  
Wacław Romaniuk ◽  
Andrzej Borusiewicz

Wind power plants are an increasingly common source of electricity located in rural areas. As a result of the high variability of wind power, and thus the generated power, these sources should be classified as unstable sources. In this paper, the authors attempted to determine the impact of wind turbine operation on the parameters of electricity supplied to farms located near the source. As a result of the conducted field tests, variability courses of the basic parameters describing the supply voltage were obtained. The influence of power plant variability on the values of voltage, frequency, and voltage distortion factor was determined. To estimate the capacity of the transmission lines, the reactive power produced in the power plant and its effect on the value of the power factor were determined. The conducted research and analysis showed that the wind power plant significantly influences voltage fluctuations in its immediate vicinity (the maximum value registered was close to 2%, while the value required by law was 2.5%). Although all the recorded values are within limits specified by the current regulations (e.g., the THD value is four times lower than the required value), wind turbines may cause incorrect operation of loads connected nearby. This applies mainly to cases where consumers sensitive to voltage fluctuations are installed in the direct vicinity of the power plant.


Nanoscale ◽  
2021 ◽  
Author(s):  
Xianyun Peng ◽  
Junrong Hou ◽  
Yuying Mi ◽  
Jiaqiang Sun ◽  
Gaocan Qi ◽  
...  

Electrocatalytic hydrogen evolution reaction (HER) for H2 production is essential for future renewable and clean energy technology. Screening energy-saving, low-cost, and highly active catalysts efficiently, however, is still a grand...


Sign in / Sign up

Export Citation Format

Share Document