scholarly journals Macro- and micro-element analysis in milk samples by inductively coupled plasma-optical emission spectrometry

2016 ◽  
pp. 51-62 ◽  
Author(s):  
Sanja Petrovic ◽  
Sasa Savic ◽  
Zivomir Petronijevic

The paper describes the determination of Ag, Al, B, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Na, Ni, Pb, Sr, Tl and Zn, as well as total fat content of milk samples, originated from different sources. The analyzed milk samples were: human milk, fresh cow milk, pasteurized cow milk from a local market, and reconstituted powder milk. The milk samples were obtained from Jablanica District (Serbia) territory. Preparation of samples for macro- and micro-analyses was done by wet digestion. Concentrations of the elements after digestion were determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Total fat content of milk samples was determinate by the Weibull and Stoldt method. The results showed that potassium and calcium concentrations were the highest in all samples: 1840.64 - 2993.26 mg/L and 456.05 - 1318.08 mg/L, respectively. Of all heavy metals from the examined milk samples (copper, zinc, manganese, nickel, cadmium, and lead), the most common were zinc and copper, with approximately similar content in the range of 5 - 12 mg/l, while cadmium nickel and manganese were not detected at all. Samples of fresh cow milk and human milk showed the highest fat content of 3.6 and 4.2 %, respectively. Results for total fat and macro- and micro-analyses showed that fresh cow milk has the highest contents of fat and calcium, making it the most nutritious.

Nutrients ◽  
2018 ◽  
Vol 10 (9) ◽  
pp. 1218 ◽  
Author(s):  
Ching Lai ◽  
Hazel Gardner ◽  
Donna Geddes

Sodium (Na), potassium (K), and the ratio Na:K in human milk (HM) may be useful biomarkers to indicate secretory activation or inflammation in the breast. Previously, these elements have been measured in a laboratory setting requiring expensive equipment and relatively large amounts of HM. The aim of this study was to compare measurements of Na and K in HM using inductively coupled plasma optical emission spectrometry (ICP-OES) with small portable ion selective electrode probes for Na and K. Sixty-five lactating women donated 5 mL samples of HM. Samples were analyzed with two ion selective probes (Na and K) and also ICP-OES. The data were analyzed using paired t-test and Bland–Altman plots. Na concentrations were not significantly different when measured with ion selective electrode (6.18 ± 2.47mM; range: 3.59–19.8) and ICP-OES (5.91 ± 3.37 mM; range: 2.59–21.5) (p = 0.20). K concentrations measured using the ion selective electrode (11.7 ± 2.21 mM: range: 7.69–18.1) and ICP-OES (11.1 ± 1.55 mM: range: 7.91–15.2) were significantly different (p = 0.01). However, the mean differences of 0.65 mM would not be clinically relevant when testing at point of care. Compared to ICP-OES, ion selective electrode is sufficiently accurate to detect changes in concentrations of Na and K in HM associated with secretory activation and inflammation in the mammary gland.


Author(s):  
Masoud Aghahoseini ◽  
Gholamhassan Azimi ◽  
M. K. Amini

Determination of traces of Cd, Co, Cu, Mn and Pb elements in zirconium and its alloys by inductively coupled plasma optical emission spectrometry (ICP OES) suffers from severe spectral interferences...