scholarly journals Pars plana vitrectomy with extraction of intraocular foreign body in patients with siderosis of the eye: Report of two cases

2013 ◽  
Vol 141 (5-6) ◽  
pp. 371-374
Author(s):  
Igor Kovacevic ◽  
Ivan Stefanovic ◽  
Milos Jovanovic ◽  
Jelena Potic ◽  
Goran Damjanovic

Introduction. Penetrating injury is characterized by the existence of entry wound only, and it can be with or without an intraocular foreign body (IOFB). IOFB can lead to a mechanical injury of the eye and to cause infection or to manifest other toxic effects on intraocular structures. Iron and copper can dissolve and cause siderosis, i.e. chalcosis of the eye. Ocular siderosis is diagnosed by clinical and electroretinogram (ERG) findings. Outline of Cases. The first patient was a 37?year?old male who was injured by a metal foreign body. He presented at the Clinic two years after the injury. Visual acuity of the right eye (VOD) on admission was VOD=L+P+ (light projection). Pars plana phacovitrectomy with IOFB extraction was done. Visual acuity on discharge was VOD=3/60 cc + 7.50 Dsph=0.2. The second patient was a 55?year?old male who presented at the clinic 18 months after injury. On admission visual acuity in his left eye was VOS 1/60. Pars plana phacovitrectomy with IOFB extraction was done. Visual acuity on discharge was VOS=0.7 through the stenopeic slit. Conclusion. In penetrating injuries caused by a metal IOFB pars plana vitrectomy with IOFB extraction is indicated. In cases with IOFB, when visual acuity is preserved, the lens is transparent, while the eye is without signs of infection, urgent pars plana vitrectomy is not necessary. Such patients need regular follow?up with obligatory ERG findings.

2020 ◽  
Vol 58 (226) ◽  
Author(s):  
Lily Rajbanshi ◽  
Archana Kumari ◽  
Sanjay Singh

Firecracker induced open globe injury is a big challenge for ophthalmic surgeons. Its associationwith the intraocular foreign body makes the diagnosis and treatment even more difficult resultingin poor anatomical and visual outcomes. We report a case of a 35-year-old male who presented withbilateral, multiple corneal and intraocular foreign body due to firecracker explosion. His vision waslimited to hand movement in both eyes. Combined penetrating keratoplasty and cataract surgerywere done in both eyes followed by pars plana vitrectomy for intraocular foreign body removal.The final best-corrected visual acuity of the patient stood to be 6/6 and 6/9 in the right and left eyerespectively. The encouraging result in our case prompts ophthalmologists for a timely stepwisemultidisciplinary approach in all open globe injuries with intraocular foreign body cases havingpoor initial acuity.


2021 ◽  
Vol 13 (1) ◽  
pp. 22-30
Author(s):  
Bikram Bahadur Thapa ◽  
Sweta Singh ◽  
Gyanendra Lamichhane ◽  
Shanti Gurung ◽  
Saurav Piya

Introduction: Posterior segment retained Intraocular foreign body (IOFB) management is challenging. Facility of pars plana vitrectomy (PPV) and availability of well trained vitreo retina surgeons are the basic need to accomplish this work.  Encircling band provide permanent 360° support to close the anterior retinal break and prevent traction on the retina. The objective of this study is to analyse the clinical characteristics and predictors of the final visual outcome and survival of the globe in cases of retained IOFB in the posterior eye segment. Materials and methods: A hospital based retrospective observational study was conducted. All the patients of retained IOFB in the posterior segment presented from January 2016 to June 2019 were enrolled. Patients presented with visual acuity of NPL were excluded. Statistical analysis was performed using a variety of tests using SPSS version 21.   Results: Forty eyes of 40 patients were included. The mean age was 27.08±10.68 years (range 5-66). 95% of our patients were male. Most of them (52.5%) worked on the farm. 26(65%) of 40 eyes had Zone I injury. The median time spent before presentation was 13.5 day. Retinal detachment, vitreous hemorrhage, and endophthalmitis were present in 15, 23 and 5 eyes, respectively, before IOFB removal. The mean LogMAR visual acuity was improved significantly from 2.50±0.87 to 1.33± 1.01 (p=0.003). Poor presenting visual acuity, retinal detachment and large diameter of IOFB were found as the predictor of poor final visual acuity. Conclusion:  Pars plana vitrectomy by a vitreo retinal surgeon can give encouraging results in the cases of retained posterior segment IOFB. Poor presenting visual acuity, large diameter of IOFB and RD before IOFB removal are predictors of poor visual outcome.


2017 ◽  
Vol 8 (1) ◽  
pp. 116-119 ◽  
Author(s):  
Irini Chatziralli ◽  
George Theodossiadis ◽  
Maria Douvali ◽  
Alexandros A. Rouvas ◽  
Panagiotis Theodossiadis

Introduction: Postoperative eccentric macular hole (MH) formation is an uncommon complication after pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling for epiretinal membrane or MH treatment. Herein, we present a case of eccentric MH formation after PPV with ILM peeling for MH. Case Description: A 72-year-old female patient underwent 23-gauge PPV with ILM peeling for idiopathic MH in her right eye. The visual acuity was 6/24 in the right eye. One week postoperatively the retina was attached and the MH seemed to be closed, while visual acuity was 6/12. One month after PPV, there was a single eccentric retinal hole below the macula, which was detected at the fundoscopy and was confirmed by OCT. The visual acuity was 6/9 and the patient referred no symptoms. No further intervention was attempted, and at the 6-month follow-up the visual acuity and the size of the eccentric MH remained stable. Conclusions: Eccentric MHs can develop after PPV and are usually managed conservatively by observation.


2013 ◽  
Vol 141 (1-2) ◽  
pp. 81-84 ◽  
Author(s):  
Igor Kovacevic ◽  
Aleksandar Gakovic ◽  
Ivan Stefanovic ◽  
Smiljka Djuric ◽  
Sofija Davidovic ◽  
...  

Introduction. An intraocular foreign body may traumatize the eye mechanically, introduce infection or exert other toxic effects on the intraocular structures. Removal of a metallic intraocular foreign bodies (IOFB) use an internal (vitrectomy followed by forceps or internal magnet use) or external approach (large electromagnet). Outline of Cases. A 51-year-old man sustained injury of the left eye by a metal foreign body. On admission visual acuity was normal (VOS=1.0) and intraocular tension was within normal limits (TOS=10 mmHg). Nasal scleral entry wound was noticed. Ultrasound of the left eye was done, which confirmed existence of IOFB laying nasally, next to the ciliary body. Extraction of IOFB with a big electric magnet was done. Visual acuity on discharge was the same (VOS=1.0). Another man, aged 30 years, came to the clinic after injury of the left eye by a foreign body. On admission visual acuity was VOS=L+P+ (light and projection), TOS=44 mmHg (higher), traumatic cataract, scleral entry wound, corneal edema, existence of IOFB and initial endophtalmitis. Lensectomia and vitrectomia via pars plana with IOFB extraction were done. Visual acuity on discharge was VOS=5/60 with +6.50 Dsph = 0.3-0.4; TOS=17 mmHg. Conclusion. Magnet removal is indicated in patients when IOFB is laying free in the vitreous body or stopped near the entry wound during injury without other complications. Internal approach - pars plana vitrectomy with forceps removal is used when IOFB is stuck either on the peripheral or posterior part of the retina or if there are some of aforementioned complications.


2020 ◽  
Vol 76 (1) ◽  
pp. 14-23
Author(s):  
Štěpán Rusňák ◽  
Lenka Hecová

Purpose: Penetrating eye trauma with an intraocular foreign body is very frequent, especially in men in their productive age. Pars plana vitrectomy would be the standard surgical method at our department. However, in indicated cases (metallic intraocular bodies in the posterior eye segment in young patients with well transparent ocular media without detached ZSM and without any evident vitreoretinal traction) transscleral extraction of the intraocular foreign body is performed using the exo magnet, eventually endo magnet with a minimal PPV without PVD induction under the visual control of endo-illumination. Materials and Methods: Between June 2003 and June 2018, 66 eyes of 66 patients diagnosed with a penetrating eye trauma caused by an intraocular foreign body located in the posterior eye segment were treated. In 18 eyes (27,3 %) with a metallic foreign body in vitreous (body) or in retina, no PPV or a minimal PPV without PVD was used as a surgical method. In the remaining 48 eyes (72,7 %), a standard 20G, respectively 23G PPV method were used together with PVD induction and the foreign body extraction via endo or exo magnet. Conclusions: As demonstrated by our survey/study, in the cases of a thoroughly considered indication an experimented vitreoretinal surgeon can perform a safe NCT transscleral extraction from the posterior eye segment via exo magnet, eventually endo magnet under the visual control of a contact display system with a minimal PPV. Thereby, the surgeon can enhance the patient´s chance to preserve their own lens and its accommodative abilities as well as reduce the risk of further surgical interventions of the afflicted eye.


Author(s):  
Tomasz K. Wilczyński ◽  
Alfred Niewiem ◽  
Rafał Leszczyński ◽  
Katarzyna Michalska-Małecka

A 36-year-old patient presented to the hospital with recurrent dislocation of the intraocular lens (IOL). The patient with the diagnosis of familial ectopia lentis was first operated on for crystalline lens subluxation in the left eye in 2007 and in the right eye in 2009. In both eyes, lens extraction with anterior vitrectomy and transscleral fixation of a rigid IOL was performed. In 2011, the IOL in the right eye luxated into the vitreous cavity due to ocular trauma. The patient underwent a pars plana vitrectomy with the IOL resuturation to the sclera. Seven years later, a spontaneous vision loss in the right eye was caused by a retinal detachment. The pars plana vitrectomy with silicone oil tamponade and a consequential oil removal three months later were performed in 2018. The follow-up examination revealed recurrent IOL dislocation in the same eye. Due to a history of previous suture-related complications a decision was made to remove the subluxated rigid polymethyl-methacrylate (PMMA) IOL and fixate to sclera a sutureless SOLEKO FIL SSF Carlevale lens. The purpose of this report is to present a single case of a 36-year-old patient who was presented to the hospital with recurrent dislocation of the intraocular lens. In a three-month follow-up period, a good anatomical and functional outcome was finally obtained with transscleral sutureless intraocular lens. This lens is an option worth considering especially in a young patient with a long life expectancy and physically active.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Enchi Kristina Chang ◽  
Sanchay Gupta ◽  
Marika Chachanidze ◽  
John B. Miller ◽  
Ta Chen Chang ◽  
...  

Abstract Purpose The purpose of this study is to report the safety and efficacy of pars plana glaucoma drainage devices with pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement in patients with refractory glaucoma. Methods Retrospective case series of 28 eyes of 28 patients who underwent combined pars plana glaucoma drainage device and pars plana vitrectomy between November 2016 and September 2019 at Massachusetts Eye and Ear. Main outcome measures were intraocular pressure (IOP), glaucoma medication burden, best corrected visual acuity, and complications. Statistical tests were performed with R and included Kaplan-Meier analyses, Wilcoxon paired signed-rank tests, and Fisher tests. Results Mean IOP decreased from 22.8 mmHg to 11.8 mmHg at 1.5 years (p = 0.002), and mean medication burden decreased from 4.3 to 2.1 at 1.5 years (p = 0.004). Both IOP and medication burden were significantly lower at all follow-up time points. The probability of achieving 5 < IOP ≤ 18 mmHg with at least 20% IOP reduction from preoperative levels was 86.4% at 1 year and 59.8% at 1.5 years. At their last visit, three eyes (10.7%) achieved complete success with IOP reduction as above without medications, and 14 eyes (50.0%) achieved qualified success with medications. Hypotony was observed in 1 eye (3.6%) prior to 3 months postoperatively and 0 eyes after 3 months. Visual acuity was unchanged or improved in 23 eyes (82.1%) at their last follow-up. Two patients had a visual acuity decrease of > 2 lines. Two eyes required subsequent pars plana vitrectomies for tube obstruction, and one eye had transient hypotony. Conclusions The results of pars plana glaucoma drainage device and pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement are promising, resulting in significant IOP and medication-burden reductions through postoperative year 1.5 without additional risk of postoperative complications. Inserting glaucoma drainage devices into an existing vitrectomy sclerotomy site may potentially save surgical time by obviating the need to create another sclerotomy for tube placement and suture one of the vitrectomy ports.


2020 ◽  
Vol 2020 ◽  
pp. 1-4
Author(s):  
A. Altun

Purpose. We aimed at reminding that X-linked retinoschisis may also be seen in female patients and share our vitreoretinal surgical experience. Methods. The patient underwent pars plana vitrectomy including the closure of the macular holes with inverted ILM flap technique bilaterally. Lens extractions were performed by phacoemulsification during the removal of silicone oil endotamponade. Patient. An 18-year-old girl with X-linked retinoschisis and large macular holes in both eyes presented to the clinic of ophthalmology. It was confirmed that the patient had RS1 mutation Results. Nine-month-follow-up was uneventful for retinal findings. Significant improvement in visual acuity was achieved, and macular holes were remained closed. Conclusion. In cases with large macular holes due to XLR, an inverted ILM flap technique might be safe and effective. Four-month-silicone-endotamponade might be sufficient.


Author(s):  
Noviana Kurniasari Vivin ◽  
Ari Djatikusumo ◽  
Elvioza Elvioza ◽  
Gitalisa Andayani ◽  
Anggun Rama Yudantha ◽  
...  

Abstract Background: The incidence of nucleus drop or intraocular lens (IOL) drop as the complication of phacoemulsification increases due to the increased frequency of phacoemulsification. Pars plana vitrectomy (PPV) followed by endofragmentation and secondary IOL implantation is the choice of procedure for management. This study aims to determine the frequency, outcomes, and complication of PPV in the case of nucleus drop or IOL drop in the Department of Ophthalmology, Fakultas Kedokteran Universitas Indonesia – Rumah Sakit Cipto Mangunkusumo (FKUI-RSCM) Methods: This study is a retrospective descriptive study conducted in the Vitreoretinal Division of the Department of Ophthalmology, FKUI - RSCM. Research data was taken from the medical records of all nucleus drop or IOL drop patients underwent PPV in January 2017-December 2017. Results: There were 19 cases studied. The incidence of nucleus drop occurred in phacoemulsification surgery techniques (94.7%) and ECCE techniques (5.3%). Vitrectomy surgery was performed ≤2 weeks in 31.6% and >2 weeks in 68.4% after the patient first arrived at the vitreoretinal clinic. Most pre-PPV visual acuity was 1/60-6/60 (47.1%). In the final follow-up, visual acuity improved from 6/45 to 6/6 occurred in 42.2% of cases. Complication after PPV and secondary IOL implantation include elevated IOP (10.5%), IOL decentration (5.3%), corneal decompensation (5.3%), macular edema (5.3%), and retinal detachment (5.3%). Conclusion: Nucleus drop or IOL drop generally occurs in phacoemulsification cataract surgery techniques. Improved visual acuity was achieved after PPV and secondary IOL implantation at the end of the follow-up period. Most common post-PPV complication is elevated IOP.  


Sign in / Sign up

Export Citation Format

Share Document