scholarly journals Reliability of different three-dimensional cephalometric landmarks in cone-beam computed tomography: A systematic review

2018 ◽  
Vol 89 (2) ◽  
pp. 317-332 ◽  
Author(s):  
Alycia Sam ◽  
Kris Currie ◽  
Heesoo Oh ◽  
Carlos Flores-Mir ◽  
Manuel Lagravére-Vich

ABSTRACT Objectives: Conventional two-dimensional (2D) cephalometric radiography is an integral part of orthodontic patient diagnosis and treatment planning. One must be mindful of its limitations as it indeed is a 2D representation of a vaster three-dimensional (3D) object. Issues with projection errors, landmark identification, and measurement inaccuracies impose significant limitations, which may now be overcome with the advent of cone-beam computed tomography (CBCT). A systematic review of the reliability of different 3D cephalometric landmarks in CBCT imaging was conducted. Materials and Methods: Electronic database searches were administered until October 2017 using PubMed, MEDLINE via OvidSP, EBMR and EMBASE via OvidSP, Scopus, and Web of Science. Google Scholar was used as an adjunctive search tool. Results: Thirteen articles considering CBCT scans of human subjects from preexisting data sets were selected and reviewed. Most of the studies had methodological limitations and were of moderate quality. Because of their heterogeneity, key data from each could not be combined and were reported qualitatively. Overall, in 3D, midsagittal plane landmarks demonstrated greater reliability compared with bilateral landmarks. A minimum number of dental landmarks were reported, although most were recommended for use. Conclusions: Further research is required to evaluate the reliability of 3D cephalometric landmarks when evaluating 3D craniofacial complexes.

2011 ◽  
Vol 81 (5) ◽  
pp. 843-849 ◽  
Author(s):  
Mariko Fuyamada ◽  
Hiroyuki Nawa ◽  
Momoko Shibata ◽  
Kazuhito Yoshida ◽  
Yoshitaka Kise ◽  
...  

Abstract Objective: To compare the reproducibility of landmark identification on three-dimensional (3D) cone-beam computed tomography (CBCT) images between procedures based on traditional cephalometric definitions (procedure 1) and those tentatively proposed for 3D images (procedure 2). Materials and Methods: A phantom with embedded dried human skull was scanned using CBCT. The acquired volume data were transferred to a personal computer, and 3D images were reconstructed. Eighteen dentists plotted nine landmarks related to the jaws and teeth four times: menton (Me), pogonion (Po), upper-1 (U1), lower-1 (L1), left upper-6 (U6), left lower-6 (L6), gonion (Go), condyle (Cd), and coronoid process (Cp). The plotting reliabilities of the two procedures were compared by calculating standard deviations (SDs) in three components (x, y, and z) of coordinates and volumes of 95% confidence ellipsoid. Results: All 27 SDs for procedure 2 were less than 1 mm, and only five of them exceeded 0.5 mm. The variations were significantly different between the two procedures, and the SDs of procedure 2 were smaller than those of procedure 1 in 21 components of coordinates. The ellipsoid volumes were also smaller for procedure 2 than procedure 1, although a significant difference was not found. Conclusions: Definitions determined strictly on each three sectional images, such as for procedure 2, were required for sufficient reliability in identifying the landmark related to the jaws and teeth.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


2020 ◽  
Vol 5 (1) ◽  
Author(s):  
Ateksha Bhardwaj Khanna

Abstract Background Endodontic disease can adversely affect the quality of life and therefore early diagnosis and consequent timely treatment is of paramount importance for the Endodontist. Radiology is an essential component in treatment planning, disease monitoring and assessment of treatment outcome. Periapical radiographs and panoramic radiography are frequently utilised but they provide only two-dimensional representation of three-dimensional structures. The advent of cone beam computed tomography (CBCT) offers three-dimensional accuracy of the hard tissue images with a reasonable cost and this has revolutionised imaging of the dentomaxillofacial structures. This imaging system has been seen to overcome some limitations of conventional radiography, as brought out in this review. The improvement in the accuracy is, however, accompanied at the cost of increased radiation exposure to the patient. Nevertheless, smaller areas of exposure are normally appropriate for endodontic imaging, and adjustment in the exposure parameters can further moderate the effective dose (Loubele et al. 37(6):309-18, 2008). Aims and objectives The aim of this review is to present the pertinent literature on the various applications of cone beam computed tomography in the field of endodontics. Methods Literature was electronically searched on the following sources; Medline and Keats Library. Further, a manual search was performed on the following journals: International Endodontic Journal, Journal of Endodontics, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, Endodontology, Journal of Dental Research, European Journal of Oral Sciences & Odontology and Dentomaxillofacial Radiology. A preliminary search was performed to gain an idea of the available literature using keywords ‘Cone Beam Computed Tomography’ to view the volume of the literature evident and identify questions to be addressed in this review. The initial search showed 243 potential articles. After scrutinising the titles and abstracts of the retrieved articles, 70 relevant studies were reviewed in full text. Furthermore, ‘published guidelines on the use of CBCT’ were also searched so as to include the results as an additional source material. All the articles eligible to be included in the review were in the English language and ranged from the year 1960 to the present. Also all the studies reviewed were based on the various uses of cone beam computed tomography in the field of endodontics. The keywords used to search were ‘Cone Beam Computed Tomography (CBCT)’, ‘Conventional radiography’, ‘Applications of CBCT in endodontics’, ‘CBCT and tooth morphology’, ‘CBCT and apical periodontitis’, ‘CBCT and vertical root fractures’, ‘CBCT and resorption’, ‘CBCT and pre-surgical assessment’, ‘CBCT and dento-alveolar trauma’ and ‘CBCT and endodontic outcome’. Results Every case is unique and CBCT should be considered only after studying each case individually. CBCT imaging needs to be adopted or used where information from conventional imaging systems is either inadequate for the management of endodontic problems or inconclusive. Having said that, it is safe to state that CBCT imaging has the potential to become the first choice for endodontic treatment planning and outcome assessment, especially when new scanners with lower radiation doses and enhanced resolution would be available.


Sign in / Sign up

Export Citation Format

Share Document