Intra- and interobserver agreement of rectus femoris cross-sectional area in critically ill patients

2021 ◽  
Vol 87 (4) ◽  
Author(s):  
Ondrej HRDY ◽  
Kamil VRBICA ◽  
Marek KOVAR ◽  
Tomas KORBICKA ◽  
Roman GAL
Thorax ◽  
2011 ◽  
Vol 66 (Suppl 4) ◽  
pp. A95-A95
Author(s):  
B. Connolly ◽  
Z. Puthucheary ◽  
H. Montgomery ◽  
J. Moxham ◽  
N. Hart

2020 ◽  
Vol 8 (S1) ◽  
Author(s):  
Sophia van der Hoeven ◽  
◽  
Lorenzo Ball ◽  
Federico Constantino ◽  
David M. van Meenen ◽  
...  

Abstract Background Accumulated airway secretions in the endotracheal tube increase work of breathing and may favor airway colonization eventually leading to pneumonia. The aim of this preplanned substudy of the ‘Preventive Nebulization of Mucolytic Agents and Bronchodilating Drugs in Intubated and Ventilated Intensive Care Unit Patients trial’ (NEBULAE) was to compare the effect of routine vs on-demand nebulization of acetylcysteine with salbutamol on accumulation of secretions in endotracheal tubes in critically ill patients. Results In this single-center substudy of a national multicenter trial, patients were randomized to a strategy of routine nebulizations of acetylcysteine with salbutamol every 6 h until end of invasive ventilation, or to a strategy with on-demand nebulizations of acetylcysteine or salbutamol applied on strict clinical indications only. The primary endpoint, the maximum reduction in cross-sectional area (CSA) of the endotracheal tube was assessed with high-resolution computed tomography. Endotracheal tubes were collected from 72 patients, 36 from patients randomized to the routine nebulization strategy and 36 of patients randomized to the on-demand nebulization strategy. The maximum cross-sectional area (CSA) of the endotracheal tube was median 12 [6 to 15]% in tubes obtained from patients in the routine nebulization group, not different from median 9 [6 to 14]% in tubes obtained from patients in the on-demand nebulization group (P = 0.33). Conclusion In adult critically ill patients under invasive ventilation, routine nebulization of mucolytics and bronchodilators did not affect accumulation of airway secretions in the endotracheal tube. Trial registration Clinicaltrials.gov Identifier: NCT02159196


2019 ◽  
Vol 47 (5) ◽  
pp. 423-434 ◽  
Author(s):  
Luke M Weinel ◽  
Matthew J Summers ◽  
Lee-Anne Chapple

Muscle wasting in the intensive care unit (ICU) is common and may impair functional recovery. Ultrasonography (US) presents a modern solution to quantify skeletal muscle size and monitor muscle wasting. However, no standardised methodology for the conduct of ultrasound-derived quadriceps muscle layer thickness or cross-sectional area in this population exists. The aim of this study was to compare methodologies reported for the measurement of quadriceps muscle layer thickness (MLT) and cross-sectional area (CSA) using US in critically ill patients. Databases PubMed, Ovid, Embase, and CINAHL were searched for original research publications that reported US-derived quadriceps MLT and/or CSA conducted in critically ill adult patients. Data were extracted from eligible studies on parameters relating to US measurement including anatomical location, patient positioning, operator technique and image analysis. It was identified that there was a clear lack of reported detail and substantial differences in the reported methodology used for all parameters. A standardised protocol and minimum reporting standards for US-derived measurement of quadriceps muscle size in ICU is required to allow for consistent measurement techniques and hence interpretation of results.


2021 ◽  
Vol 10 (12) ◽  
pp. 2721
Author(s):  
Nobuto Nakanishi ◽  
Shigeaki Inoue ◽  
Rie Tsutsumi ◽  
Yusuke Akimoto ◽  
Yuko Ono ◽  
...  

Ultrasound has become widely used as a means to measure the rectus femoris muscle in the acute and chronic phases of critical illness. Despite its noninvasiveness and accessibility, its accuracy highly depends on the skills of the technician. However, few ultrasound phantoms for the confirmation of its accuracy or to improve technical skills exist. In this study, the authors created a novel phantom model and used it for investigating the accuracy of measurements and for training. Study 1 investigated how various conditions affect ultrasound measurements such as thickness, cross-sectional area, and echogenicity. Study 2 investigated if the phantom can be used for the training of various health care providers in vitro and in vivo. Study 1 showed that thickness, cross-sectional area, and echogenicity were affected by probe compression strength, probe angle, phantom compression, and varying equipment. Study 2 in vitro showed that using the phantom for training improved the accuracy of the measurements taken within the phantom, and Study 2 in vivo showed the phantom training had a short-term effect on improving the measurement accuracy in a human volunteer. The new ultrasound phantom model revealed that various conditions affected ultrasound measurements, and phantom training improved the measurement accuracy.


Author(s):  
Suhani Patel ◽  
Claire M Nolan ◽  
Ruth E Barker ◽  
Sarah E Jones ◽  
Matthew M Maddocks ◽  
...  

2017 ◽  
Vol 49 (5S) ◽  
pp. 901-902
Author(s):  
Thomas J. Kopec ◽  
Bailey A. Welborn ◽  
James E. Leeper ◽  
Elizabeth E. Hibberd ◽  
Phillip A. Bishop ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document