scholarly journals UV-Vis Spectrophotometric Determination of Selected Heavy Metals (Pb, Cr, Cd and As) in Environmental, Water and Biological Samples with Synthesized Glutaraldehyde Phenyl Hydrazone as the Chromogenic Reagent

2021 ◽  
Vol 2 (3) ◽  
pp. 1-5
Author(s):  
Samuel Echioda ◽  
Adepeju Oluwabunmi Ogunieye ◽  
Salisu Salisu ◽  
Amina Abdulazeez Abdulrasheed ◽  
I. Y. Chindo ◽  
...  

A simple, sensitive, selective, and non-extractive UV-Vis spectrophotometric method for the determination of cadmium, lead, chromium, and arsenic in biological, soil and water samples using synthesized and characterized phenyl hydrazone; glutaraldehydephenyl hydrazone (GPH) as the chromogenic reagent was developed. GPH was synthesized as new chromogenic analytical reagents for the direct UV-Vis spectrophotometric determination of the selected metals of interest in a slightly acidic pH of 6.5-7.5 and 20 % dimethylformamide (DMF) solution to give stable coloured metal-ligand complexes. The reactions were instantaneous; the wavelengths of maximum absorptions were followed spectrophotometrically and noted. The reagent GPH revealed a wavelength of maximum absorption between 360.0 (Cr) to 395.0 nm for (Pb and As) at a working pH of 6.5 to 7.5 room temperature (37 °C). The reagent GPH had a molar absorptivity (L mol-1 cm-1) ranging from 2.213×104 (Pb) to 2.460×104 (As), a mole ratio of metal to ligand of 2:1, the detection limit (µg/g) ranging from 0.3432 (As) to 0.5250 (Pb) and the metal-ligand complex was stable for 0-48 hours. The reagents had a Beer’s law validity range (mg L-1) of 0.001 to 100. The Sandell’s sensitivities (µg/cm2) ranged from 0000409 (As) to 0.00499 (Pb) for APDH and 0.00406 (As) to 0.00452 (Pb) respectively. Large excess of cations and anions as possible interferences up to 15 folds were studied and do not interfere with the determination of the selected metals of interest. The developed method is highly selective for Cd, Pb, and Cr and As and was successfully used for the determination for the said elements in soil, water, and biological samples. The results of the developed methods were comparable with AAS and were found to be in good agreement. The method had very high precision and very good accuracy.

2015 ◽  
Vol 98 (1) ◽  
pp. 218-224 ◽  
Author(s):  
Shuo Wang ◽  
Xv Dong ◽  
Bingye Dai ◽  
Mingfei Pan ◽  
Shaoyuan He ◽  
...  

Abstract A method was developed for detection of V, Cr, Cu, As, and Pb in water and biological samples by combining online flow injection and preconcentration with inductively coupled plasma-MS. The 2-nitroso-1-naphthol-4-sulfonic acid (Nitroso-S) impregnated MCI GEL CHP20P resin was prepared as an enrichment sorbent. Some parameters affecting the efficiency of the preconcentration process were investigated in the experiment, including the pH and volume of sample solution, the flow rate for sample loading, the type and concentration of eluent, and the influence of co-existing ions. Under the optimal experimental conditions, the enrichment factor and LOD (3s) of chosen metal ions V, Cr, Cu, As, and Pb were in the ranges of 71–268 and 4.89–23.76 ng/L, respectively. Based on 11 repeated measurementsof standard solutions (1.0 μg/L), the RSD ofthe ions ranged from 1.2 to 2.9%. The detection procedure was also performed for analyzing two certifiedreference materials, GBW 08607 (water) and GBW 10052 (green tea), as well as environmental water and biological samples. Good agreement with certified valuesand high recoveries have demonstrated improved accuracy of the proposed method.


Sign in / Sign up

Export Citation Format

Share Document