scholarly journals Primary Frequency Response Reserve Products for Inverter-Based Resources

2022 ◽  
Author(s):  
Manuel Garcia ◽  
Ross Baldick ◽  
Felipe Wilches-Bernal
Electricity ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 143-157
Author(s):  
Jovi Atkinson ◽  
Ibrahim M. Albayati

The operation and the development of power system networks introduce new types of stability problems. The effect of the power generation and consumption on the frequency of the power system can be described as a demand/generation imbalance resulting from a sudden increase/decrease in the demand and/or generation. This paper investigates the impact of a loss of generation on the transient behaviour of the power grid frequency. A simplified power system model is proposed to examine the impact of change of the main generation system parameters (system inertia, governor droop setting, load damping constant, and the high-pressure steam turbine power fraction), on the primary frequency response in responding to the disturbance of a 1.32 GW generation loss on the UK power grid. Various rates of primary frequency responses are simulated via adjusting system parameters of the synchronous generators to enable the controlled generators providing a fast-reliable primary frequency response within 10 s after a loss of generation. It is concluded that a generation system inertia and a governor droop setting are the most dominant parameters that effect the system frequency response after a loss of generation. Therefore, for different levels of generation loss, the recovery rate will be dependent on the changes of the governor droop setting values. The proposed model offers a fundamental basis for a further investigation to be carried on how a power system will react during a secondary frequency response.


2016 ◽  
Vol 88 ◽  
pp. 985-990 ◽  
Author(s):  
Fei Teng ◽  
Yunfei Mu ◽  
Hongjie Jia ◽  
Jianzhong Wu ◽  
Pingliang Zeng ◽  
...  

2019 ◽  
Vol 8 (1) ◽  
pp. 91
Author(s):  
Seyed Saed Heidary Yazdi ◽  
Jafar Milimonfared ◽  
Seyed Hamid Fathi

Lack of synchronism between VSC-HVDC (Voltage Source Converter - High Voltage Direct Current) connected offshore wind farm and onshore grid leads to immunity of wind turbines to grid contingencies. Focusing on DFIG (Doubly Fed Induction Generator) based wind farms; this paper has presented a univalent control structure based on inertial and primary frequency response in which DC link voltage is utilized as synchronization interface. Based on the presented structure, four approaches based on the communication system, frequency, voltage and combined frequency and voltage modulation are utilized and compared to inform the onshore grid status to individual wind turbines. Considering Kondurs two area power system, results have revealed that all four approaches have similar ability (with negligible error) in offering inertial and primary frequency response to improve slow network oscillations. On the other hand, voltage and combined frequency and voltage modulation approaches have the ability to satisfy Fault Ride Through (FRT) requirements thanks to superior dynamics. However, communication and frequency modulation approaches lose that ability as communication and frequency measurement delays increase respectively. It has been concluded that combined frequency and voltage modulation, as the superior approach, has advantages like minimum FRT DC voltage profile increase and deviation from operating point after the fault, the minimum imposition of electrical and mechanical stress on DFIG and preservation of prevalent control structure thanks to appropriate dissociation between slow and fast dynamics.©2019. CBIORE-IJRED. All rights reservedArticle History: Received Dec 8th 2017; Received in revised form July 16th 2018; Accepted December 15th 2018; Available onlineHow to Cite This Article: Yazdi, S.S.H., Milimonfared, J. and Fathi, S.H. (2019). Adaptation of VSC-HVDC Connected DFIG Based Offshore Wind Farm to Grid Codes: A Comparative Analysis. Int. Journal of Renewable Energy Development, 8(1), 91-101.https://doi.org/10.14710/ijred.8.1.91-101


Sign in / Sign up

Export Citation Format

Share Document