Bender-Gestalt Test and Background Interference Procedure in Discernment of Organic Brain Damage

1975 ◽  
Vol 40 (1) ◽  
pp. 103-109 ◽  
Author(s):  
Angela M. Pardue

Although the Bender-Gestalt test has proven adequate in differentiating groups of organic from groups of nonorganic Ss, attempts at individual diagnosis have frequently met with failure. Canter's Background Interference Procedure was designed to increase the sensitivity of the Bender test to the discernment of organic brain damage. The purpose of this paper was to check the validity of the Canter procedure, and to investigate its applicability to Hain's scoring system for the Bender test. 20 brain-damaged patients, 20 schizophrenics, and 20 nonorganic, non-brain-damaged patients were matched for age and intelligence. Each of these groups was further divided into outpatients and inpatients All patients were administered the Bender test on the standard white paper, the WAIS vocabulary subtest, and again the Bender test, on paper for the Background Interference Procedure. Significant results were obtained with the Background Interference administration for both Pascal-Suttell's and Hain's scoring systems where the standard administration had failed to yield significance. The tentative criteria proposed by Canter for individual diagnosis, however, were adequate for Pascal-Suttell's scoring system but not for Hain's method. Possible explanations for this disagreement, as well as suggestions for further research, are offered.

1993 ◽  
Vol 77 (3) ◽  
pp. 883-893 ◽  
Author(s):  
Laura Parsons ◽  
Sharon Lawner Weinberg

Although several objective scoring systems have been developed for use with the abbreviated form of the Bender-Gestalt test of visuomotor development (Figures A, 1, 2, 4, 6, and 8), each has been criticized as being inadequate in some way or other. This paper reviews the inadequacies of these systems as described in the literature and presents the results of a small study designed to investigate the psychometric properties of a new objective scoring system, recently proposed by Sugar, which incorporates both quantitative and qualitative perspectives. The new system is shown to be psychometrically sound in validity and reliability. Additional advantages are described. The new system is recommended as a good, if not better, alternative to other, existing methods for scoring the Bender-Gestalt test.


2000 ◽  
Vol 90 (1) ◽  
pp. 209-214 ◽  
Author(s):  
Po Wah Chan

This study compared the Qualitative Scoring System for the Modified Version of the Bender-Gestalt test and the Developmental Scoring System for the Bender-Gestalt test in predicting performance on the Standardized Attainment Test of young children in Hong Kong. The study was done in two phases. First, 748 middle class children ages 4 to 8 years from 6 kindergartens and 6 primary schools were given the Bender-Gestalt test individually in kindergarten and in groups for older children, respectively. Both scoring systems were used to measure the children's visual motor development. Second, among the participants' protocols, 257 Primary 1 to Primary 3 children ages 6 to 8 years were selected to compare the Qualitative Scoring System for the 6 designs of the Modified Version of the Bender-Gestalt test and the Developmental Scoring System for the 9 designs of the Bender-Gestalt test in predicting performance on the Standardized Attainment Test. Results indicated that the Qualitative Scoring System differentiates better than the Developmental Scoring System in evaluating visual-motor development among young Chinese children from Hong Kong. Results also indicated that the Qualitative Scoring System correlated significantly with achievement in Chinese and English at all three levels. Scores on the Developmental Scoring System correlated significantly with only marks for Primary 1 and Primary 2 Chinese.


Author(s):  
Edoardo Cipolletta ◽  
Emilio Filippucci ◽  
Andrea Di Matteo ◽  
Giulia Tesei ◽  
Micaela Ana Cosatti ◽  
...  

Abstract Purpose i) To assess the inter- and intra-observer reliability of ultrasound (US) in the evaluation of the hyaline cartilage (HC) of the metacarpal head (MH) in patients with rheumatoid arthritis (RA) and in healthy subjects (HS) both qualitatively and quantitatively. ii) To calculate the smallest detectable difference (SDD) of the MH cartilage thickness measurement. iii) To correlate the qualitative scoring system and the quantitative assessment. Materials and Methods US examination was performed on 280 MHs of 20 patients with RA and 15 HS using a very high frequency probe (up to 22 MHz). HC status was evaluated both qualitatively (using a five-grade scoring system) and quantitatively (using the average value of the longitudinal and transverse measures). The HC of MHs from II to V metacarpophalangeal joint of both hands were scanned independently on the same day by two rheumatologists to assess inter-observer reliability. All subjects were re-examined using the same scanning protocol and the same US setting by one sonographer after a week to assess intra-observer reliability. Results The inter-observer agreement and intra-observer agreement were moderate to substantial (k = 0.66 and k = 0.73) for the qualitative scoring system and high (ICC = 0.93 and ICC = 0.94) for the quantitative assessment. The SDD of the MH cartilage thickness measurement was 0.09 mm. A significant correlation between the two scoring systems was found (r = –0.35; p < 0.001). Conclusion The present study describes the main methodological issues of HC assessment. Using a standardized protocol, both the qualitative and the quantitative scoring systems can be reliable.


2021 ◽  
pp. 021849232110304
Author(s):  
Mehrnoush Toufan ◽  
Zahra Jabbary ◽  
Naser Khezerlou aghdam

Background To quantify valvular morphological assessment, some two-dimensional (2D) and three-dimensional (3D) scoring systems have been developed to target the patients for balloon mitral valvuloplasty; however, each scoring system has some potential limitations. To achieve the best scoring system with the most features and the least restrictions, it is necessary to check the degree of overlap of these systems. Also the factors related to the accuracy of these systems should be studied. We aimed to determine the correlation between the 2D Wilkins and real-time transesophageal three-dimensional (RT3D-TEE) scoring systems. Methods This cross-sectional study was performed on 156 patients with moderate to severe mitral stenosis who were candidates for percutaneous balloon valvuloplasty. To morphologic assessment of mitral valve, patients were examined by 2D-transthoracic echocardiography and RT3D-TEE techniques on the same day. Results A strong association was found between total Wilkins and total RT3D-TEE scores (r = 0.809, p < 0.001). The mean mitral valve area assessed by the 2D and 3D was 1.07 ± 0.25 and 1.03 ± 0.26, respectively, indicating a mean difference of 0.037 cm2 (p = 0.001). We found a strong correlation between the values of mitral valve area assessed by 2D and 3D techniques (r = 0.846, p < 0.001). Conclusion There is a high correlation between the two scoring systems in terms of evaluating dominant morphological features. Partially, mitral valve area overestimation in the 2D-transthoracic echocardiography and its inability to assess commissural involvement as well as its dependence on patient age were exceptions in this study.


2021 ◽  
Vol 20 (1) ◽  
Author(s):  
Qing Wu ◽  
Jie Wang ◽  
Mengbin Qin ◽  
Huiying Yang ◽  
Zhihai Liang ◽  
...  

Abstract Background Recently, several novel scoring systems have been developed to evaluate the severity and outcomes of acute pancreatitis. This study aimed to compare the effectiveness of novel and conventional scoring systems in predicting the severity and outcomes of acute pancreatitis. Methods Patients treated between January 2003 and August 2020 were reviewed. The Ranson score (RS), Glasgow score (GS), bedside index of severity in acute pancreatitis (BISAP), pancreatic activity scoring system (PASS), and Chinese simple scoring system (CSSS) were determined within 48 h after admission. Multivariate logistic regression was used for severity, mortality, and organ failure prediction. Optimum cutoffs were identified using receiver operating characteristic curve analysis. Results A total of 1848 patients were included. The areas under the curve (AUCs) of RS, GS, BISAP, PASS, and CSSS for severity prediction were 0.861, 0.865, 0.829, 0.778, and 0.816, respectively. The corresponding AUCs for mortality prediction were 0.693, 0.736, 0.789, 0.858, and 0.759. The corresponding AUCs for acute respiratory distress syndrome prediction were 0.745, 0.784, 0.834, 0.936, and 0.820. Finally, the corresponding AUCs for acute renal failure prediction were 0.707, 0.734, 0.781, 0.868, and 0.816. Conclusions RS and GS predicted severity better than they predicted mortality and organ failure, while PASS predicted mortality and organ failure better. BISAP and CSSS performed equally well in severity and outcome predictions.


2021 ◽  
pp. 25-28
Author(s):  
M. Vijaya Kumar ◽  
Manasa Manasa

Acute appendicitis is the most common condition encountered in the Emergency department .Alvarado and Modied Alvarado scores are the most commonly used scoring system used for diagnosing acute appendicitis.,but its performance has been found to be poor in certain population . Hence our aim was to compare the diagnostic accuracy of RIPASA and ALVARADO Scoring system and study and compare sensitivity, specicity and predictive values of these scoring systems. The study was conducted in Government district hospital Nandyal . We enrolled 176 patients who presented with RIF pain . Both RIPASA and ALVARADO were applied to them. Final diagnosis was conrmed either by CT scan, intra operative nding or post operative HPE report. Sensitivity,specicity, positive predictive value, negative predictive value, diagnostic accuracy was calculated both for RIPASA and ALVARADO. It was found that sensitivity and specicity of the RIPASA score in our study are 98.7% and 83.3%, respectively. PPV and NPV were 98.1% and 88.2% and sensitivity and specicity of the Alvardo score in our study are 94.3% and 83.3%, respectively. PPV and NPV were 98% and 62.5%.Diagnostic accuracy of RIPASA score and Alvarado score are 97% and 93% respectively. RIPASA is a more specic and accurate scoring system in our local population when compared to ALVARADO . It reduces the number of missed appendicitis cases and also convincingly lters out the group of patients that would need a CT scan for diagnosis (score 5-7.5 ) BACKGROUND: Acute appendicitis is one of the most commonly dealt surgical emergencies, with a lifetime prevalence rate of approximately 1 one in seven. The incidence is 1.5–1.9 per 1,000 in the male and female population, and is approximately 1.4 times greater in men than in women. Despite being a common problem, it remains a difcult diagnosis to establish, particularly among the young, the elderly and females of reproductive age, where a host of other genitourinary and gynaecological inammatory conditions can present with signs and symptoms that are 2 similar to those of acute appendicitis. A delay in performing an appendectomy in order to improve its diagnostic accuracy increases the risk of appendicular perforation and peritonitis, which in turn increases morbidity and mortality. A variable combination of clinical signs and symptoms has been used together with laboratory ndings in several scoring systems proposed for suggesting the probability of Acute Appendicitis and the possible subsequent management pathway. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) and ALVARADO score are new diagnostic scoring systems developed for the diagnosis of Acute Appendicitis and has been shown to have signicantly higher sensitivity, specicity and diagnostic accuracy. AIMS AND OBJECTIVES PRIMARY OBJECT 1. To compare RIPASA Scoring system and ALVARADO Scoring system in terms of diagnostic accuracy in Acute Appendicitis. 2. To study and compare sensitivity, specicity and predictive values of above scoring systems. SECONDARY OBJECT 1. To study the rate of negative appendicectomy based on above scoring systems. CONCLUSION: The RIPASA score is a simple scoring system with high sensitivity and specicity for the diagnosis of acute appendicitis. The 14 clinical parameters are all present in a good clinical history and examination and can be easily and quickly applied. Therefore, a decision on the management can be made early. Although the RIPASA score was developed for the local population of Brunei, we believe that it should be applicable to other regions. The RIPASA score presents greater Diagnostic accuracy and Sensitivity and equal specicity as a diagnostic test compared to the Alvarado score and is helpful in making appropriate therapeutic decisions. In hospitals like ours, the diagnosis of AA relies greatly on the clinical evaluation performed by surgeons. An adequate clinical scoring system would avoid diagnostic errors, maintaining a satisfactory low rate of negative appendectomies by adequate patient stratication, while limiting patient exposure to ionizing radiation, since 21 there is an increased risk of developing cancer with computed tomography, particularly for the paediatric age group.


Sign in / Sign up

Export Citation Format

Share Document