scholarly journals A New Neutrosophic Approach of Wiener Filtering for MRI Denoising

2013 ◽  
Vol 13 (4) ◽  
pp. 177-186 ◽  
Author(s):  
J. Mohan ◽  
V. Krishnaveni ◽  
Yanhui Guo

In this paper, a new filtering method based on neutrosophic set (NS) approach of wiener filter is presented to remove Rician noise from magnetic resonance image. A neutrosophic set, a part of neutrosophy theory, studies the origin, nature and scope of neutralities, as well as their interactions with different ideational spectra. Now, we apply the neutrosophic set into image domain and define some concepts and operators for image denoising. The image is transformed into NS domain, described using three membership sets: True (T), Indeterminacy (I) and False (F). The entropy of the neutrosophic set is defined and employed to measure the indeterminacy. The ω-wiener filtering operation is used on T and F to decrease the set indeterminacy and remove noise. The experiments have conducted on simulated Magnetic Resonance images (MRI) from Brainweb database and clinical MR images corrupted by Rician noise. The results show that the NS wiener filter produces better denoising results in terms of visual perception, qualitative and quantitative measures compared with other denoising methods, such as classical wiener filter, the anisotropic diffusion filter, the total variation minimization scheme and non local means filter.

Magnetic resonance image noise reduction is important to process further and visual analysis. Bilateral filter is denoises image and also preserves edge. It proposes Iterative bilateral filter which reduces Rician noise in the magnitude magnetic resonance images and retains the fine structures, edges and it also reduces the bias caused by Rician noise. The visual and diagnostic quality of the image is retained. The quantitative analysis is based on analysis of standard quality metrics parameters like peak signal-to-noise ratio and mean structural similarity index matrix reveals that these methods yields better results than the other proposed denoising methods for MRI. Problem associated with the method is that it is computationally complex hence time consuming. It is not recommended for real time applications. To use in real time application a parallel implantation of the same using FPGA is proposed.


2020 ◽  
Vol 13 (4) ◽  
pp. 14-31
Author(s):  
Nikita Joshi ◽  
Sarika Jain ◽  
Amit Agarwal

Magnetic resonance (MR) images suffer from noise introduced by various sources. Due to this noise, diagnosis remains inaccurate. Thus, removal of noise becomes a very important task when dealing with MR images. In this paper, a denoising method has been discussed that makes use of non-local means filter and discrete total variation method. The proposed approach has been compared with other noise removal techniques like non-local means filter, anisotropic diffusion, total variation, and discrete total variation method, and it proves to be effective in reducing noise. The performance of various denoising methods is compared on basis of metrics such as peak signal-to-noise ratio (PSNR), mean square error (MSE), universal image quality index (UQI), and structure similarity index (SSIM) values. This method has been tested for various noise levels, and it outperformed other existing noise removal techniques, without blurring the image.


Sign in / Sign up

Export Citation Format

Share Document