scholarly journals Review on Heat Transfer Augmentation Techniques: Application in Gas Turbine Blade Internal Cooling

2012 ◽  
Vol 5 (1) ◽  
pp. 57-62 ◽  
Author(s):  
S. Gupta ◽  
◽  
A. Chaube ◽  
P. Verma ◽  
◽  
...  
2007 ◽  
Vol 130 (1) ◽  
Author(s):  
Evan A. Sewall ◽  
Danesh K. Tafti

The problem of accurately predicting the flow and heat transfer in the ribbed internal cooling duct of a rotating gas turbine blade is addressed with the use of large eddy simulations (LES). Four calculations of the developing flow region of a rotating duct with ribs on opposite walls are used to study changes in the buoyancy parameter at a constant rotation rate. The Reynolds number is 20,000, the rotation number is 0.3, and the buoyancy parameter is varied between 0.00, 0.25, 0.45, and 0.65. Previous experimental studies have noted that leading wall heat transfer augmentation decreases as the buoyancy parameter increases with low buoyancy, but heat transfer then increases with high buoyancy. However, no consistent physical explanation has been given in the literature. The LES results from this study show that the initial decrease in augmentation with buoyancy is a result of larger separated regions at the leading wall. However, as the separated region spans the full pitch between ribs with an increase in buoyancy parameter, it leads to increased turbulence and increased entrainment of mainstream fluid, which is redirected toward the leading wall by the presence of a rib. The impinging mainstream fluid results in heat transfer augmentation in the region immediately upstream of a rib. The results obtained from this study are in very good agreement with previous experimental results.


Author(s):  
James Batstone ◽  
David Gillespie ◽  
Eduardo Romero

A novel form of gas turbine blade or vane cooling in which passages repeatedly branch within the wall of the cooled component is introduced in this paper. These so called dendritic cooling geometries offer particular performance improvements compared to traditional cooling holes where the external cross flow is low, and conventional films have a tendency to lift off the surface. In these regions improved internal cooling efficiency is achieved, while the coolant film is ejected at a low momentum ratio resulting in reduced aerodynamic losses between the film and hot gases, and a more effective surface film. By varying the number of branches of the systems at a particular location it is possible to tune the flow and heat transfer to the requirements at that location whilst maintaining the pressure margin. The additional loss introduced using the internal branching structure allows a full film-coverage arrangement of holes at the external blade surface. In this paper the results of transient heat transfer experiments characterising the internal heat transfer coefficient distribution in large scale models of dendritic passages are reported. Experiments were conducted with 1, 2 and 3 internal flow branches at a range of engine representative Reynolds numbers and exit momentum ratios. CFD models are used to help explain the flow field in the cooling passages. Furthermore the sensitivity of the pressure loss to the blowing ratio at the exit of the cooling holes is characterised and found to be inversely proportional to the number of branches in the dendritic system. Surprisingly the highly branched systems generally do not exhibit the highest pressure losses.


Author(s):  
Naris Pattanaprates ◽  
Ekachai Juntasaro ◽  
Varangrat Juntasaro

Abstract The present work is aimed to investigate whether the modification to the bend geometry of a multipass internal cooling passage in a gas turbine blade can enhance heat transfer and reduce pressure drop. The two-pass channel and the four-pass channel are modified at the bend from the U shape to the bulb and bow shape. The first objective of the work is to investigate whether the modified design will still improve heat transfer with reduced pressure drop in a four-pass channel as in the case of a two-pass channel. It is found out that, unlike the two-pass channel, the heat transfer is not improved but the pressure drop is still reduced for the four-pass channel. The second objective is to investigate the rotating effect on heat transfer and pressure drop in the cases of two-pass and four-pass channels for both original and modified designs. It is found out that heat transfer is improved with reduced pressure drop for all cases. However, the modified design results in the less improvement on heat transfer and lower reduced pressure drop as the rotation number increases. It can be concluded from the present work that the modification can solve the problem of pressure drop without causing the degradation of heat transfer for all cases. The two-pass channel with modified bend results in the highest heat transfer and the lowest pressure drop for rotating cases.


Author(s):  
Evan A. Sewall ◽  
Danesh K. Tafti

The problem of accurately predicting the flow and heat transfer in the ribbed internal cooling duct of a rotating gas turbine blade is addressed with the use of large eddy simulations (LES). Four calculations of the developing flow region of a rotating duct with ribs on opposite walls are used to study changes in the buoyancy parameter at a constant rotation rate. The Reynolds number is 20,000, the rotation number is 0.3, and the buoyancy parameter is varied between 0.00, 0.25, 0.45, and 0.65. Previous experimental studies have noted that leading wall heat transfer augmentation decreases as the buoyancy parameter increases with low buoyancy, but heat transfer then increases with high buoyancy. However, no consistent physical explanation has been given in the literature. The LES results from this study show that the initial decrease in augmentation with buoyancy is a result of larger separated regions at the leading wall. However, as the separated region spans the full pitch between ribs with an increase in buoyancy parameter, it leads to increased turbulence and increased entrainment of mainstream fluid which is redirected toward the leading wall by the presence of a rib. The impinging mainstream fluid results in heat transfer augmentation in the region immediately upstream of a rib. The results obtained from this study are in very good agreement with previous experimental results.