A Computation Investigation of Broadband Noise Generation in a Low-Speed Axial-Fan

Author(s):  
Graham Ashcroft ◽  
Dirk Nuernberger
2016 ◽  
Vol 64 (1) ◽  
pp. 13-23 ◽  
Author(s):  
Alain Guedel ◽  
Mirela Robitu
Keyword(s):  

2013 ◽  
Vol 61 (2) ◽  
pp. 180-189 ◽  
Author(s):  
Korcan Kucukcoskun ◽  
Julien Christophe ◽  
Christophe Schram ◽  
Michel Tournour

2018 ◽  
Vol 2018 ◽  
pp. 1-12
Author(s):  
Aurélie Ortolan ◽  
Suk-Kee Courty-Audren ◽  
Nicolas Binder ◽  
Xavier Carbonneau ◽  
Yannick Bousquet ◽  
...  

A steady mixing plane approach is compared with the time-averaged solution of an unsteady full annulus calculation for a conventional fan operating at load-controlled windmill. The objective is to assess the added value of a complete unsteady calculation compared with a more classical approach, especially concerning the effect of the spatial and temporal periodicity release in such an unusual operation as windmill. Experiment with global steady measurements and rotor radial characterizations was conducted. Numerical analysis demonstrates that windmilling global performances obtained with the time-averaged solution of the unsteady simulation are not far different from the steady case, especially in the rotor. Some differences arise in the stator, particularly regarding the velocity field. Temporal periodicity release in this row has clearly a significant effect on the flow unsteady response. A detailed analysis highlights that generic patterns of windmilling flows recorded on a steady approach are also reported on the unsteady case.


2010 ◽  
Vol 128 (1) ◽  
pp. 152-163 ◽  
Author(s):  
L. Huang ◽  
X. Ma ◽  
L. G. Feng
Keyword(s):  

2014 ◽  
Vol 136 (7) ◽  
Author(s):  
Chetan Mistry ◽  
A. M. Pradeep

The influence of circumferential inflow distorted on the performance and flow behavior of a high aspect ratio, low speed contra rotating fan is reported in this paper. The total pressure at the inlet is artificially distorted by means of 90 deg mesh sector with a porosity of 0.70. The performance of the contra rotating fan was studied under different speed combinations of the two rotors under clean and distorted inflow conditions. Detailed flow analyses were conducted under design and off-design conditions. In order to understand the effect of distortion and its extent, the distortion sector was rotated circumferentially at intervals of 15 deg to cover the entire annulus. Detailed measurements of the total pressure, velocity components, and flow angles were carried out at the inlet of the first rotor, between the two rotors, and at the exit of the second rotor. The study reveals a few interesting aspects on the effect of inflow distortion on the performance of a contra-rotating stage. For the design speed combination and lower rotational speed of rotor-2, a reduction in the overall operating range with a shift of the peak pressure point towards higher mass flow rate, was observed. It is observed that the effect of inflow distortion at the inlet of rotor-1 gets transferred in the direction of rotor-1 rotation and spreads across the entire annulus. The opposite sense of rotation of rotor-2 causes the distortion effect to get transferred in the direction of rotation of rotor-2 with an associated reduction in the total pressure near the hub. It is observed that a higher rotational speed of the second rotor has a beneficial effect on the overall performance due to the strong suction by generated higher rotational speed of rotor-2.


2021 ◽  
Author(s):  
Sumit Tambe ◽  
Ugaitz Bartolom\xe9 Oseguera ◽  
Arvind Gangoli Rao

Author(s):  
Sumit Tambe ◽  
Ugaitz Bartolomé Oseguera ◽  
Arvind Gangoli Rao

Abstract In the pursuit of reducing the fuel burn, future aircraft configurations will feature several types of improved propulsion systems, e.g. embedded engines with boundary layer ingestion, high-bypass ratio engines with short intakes, etc. Depending on the design and phase of flight, the engine fan will encounter inflow distortion of varying strength, and fan performance will be adversely affected. Therefore, investigation of the flow phenomena causing performance losses in fan and distortion interaction is important. This experimental study shows the effect of varying distortion index on four aspects of fan performance: distortion topology, upstream redistribution, performance curve, and flow unsteadiness. A low speed fan is tested under 60° circumferential distortion of varying strength, generated using distortion screens. The flow field in the upstream redistribution region is measured using PIV (planar and stereo). The fan performance is obtained using total pressure measurements. The noise spectra measured by a microphone are used to quantify the unsteadiness in the flow field. The distortion index (DC60) varies linearly with the grid porosity at constant wall thickness and aspect ratio of the grid cells. However, the distortion topology is significantly different as a stream-wise vortex pair appears in distorted flow at higher DC60. The vortices are stronger at higher DC60, but their order of magnitude is much lower than the circulation corresponding to fan itself. The spinner, distortion index and topology significantly affect the upstream redistribution mechanism. The vortex pair redistributes the flow which results in lower asymmetry in the symmetry plane. With increasing distortion, the performance is reduced and the unsteadiness is increased.


2010 ◽  
Vol 9 (3) ◽  
pp. 237-251 ◽  
Author(s):  
V. Jurdic ◽  
P. Joseph ◽  
A. Moreau ◽  
L. Enghardt
Keyword(s):  

2010 ◽  
Vol 127 (3) ◽  
pp. 1781-1781
Author(s):  
W.C. Kirkpatrick Alberts ◽  
Kevin J. Sanchez ◽  
Mark A. Coleman ◽  
Josh Gabrielse ◽  
David A. Ligon
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document