Outcome of endoscopic reintervention for malignant hilar obstruction treated by stent-in-stent deployment

Author(s):  
Dae Hwan Kang
Medicine ◽  
2017 ◽  
Vol 96 (48) ◽  
pp. e8867 ◽  
Author(s):  
Joung Boom Hong ◽  
Dae Hwan Kang ◽  
Hyeong Seok Nam ◽  
Cheol Woong Choi ◽  
Hyung Wook Kim ◽  
...  

2012 ◽  
Vol 7 (2) ◽  
pp. 81
Author(s):  
Bruce R Brodie ◽  

This article reviews optimum therapies for the management of ST-elevation myocardial infarction (STEMI) with primary percutaneous coronary intervention (PCI). Optimum anti-thrombotic therapy includes aspirin, bivalirudin and the new anti-platelet agents prasugrel or ticagrelor. Stent thrombosis (ST) has been a major concern but can be reduced by achieving optimal stent deployment, use of prasugrel or ticagrelor, selective use of drug-eluting stents (DES) and use of new generation DES. Large thrombus burden is often associated poor outcomes. Patients with moderate to large thrombus should be managed with aspiration thrombectomy and patients with giant thrombus should be treated with glycoprotein IIb/IIIa inhibitors and may require rheolytic thrombectomy. The great majority of STEMI patients presenting at non-PCI hospitals can best be managed with transfer for primary PCI even with substantial delays. A small group of patients who present very early, who are at high clinical risk and have long delays to PCI, may best be treated with a pharmaco-invasive strategy.


2021 ◽  
pp. 159101992110251
Author(s):  
Hyun Ho Choi ◽  
Young Dae Cho ◽  
Dong Hyun Yoo ◽  
Hyun-Seung Kang ◽  
Moon Hee Han

Stenting of vertebral artery dissecting aneurysms (VADAs) may promote mural apposition of intimal flaps, preserving the patency of injured vessels. Moreover, stent deployment may serve to alter intra-aneurysm flow, inducing saccular thrombus formation, neointimal development, and remodeling of injured vessels. Although an overlapping multistent strategy with coiling has proven successful in this setting, yielding good anatomic and clinical outcomes, coiling may be technically infeasible in some VADAs with unfavorably configured circumferential elevations. Herein, we describe three patients with VADAs for whom coiling was deemed technically problematic. Each underwent double stenting (LVIS within Enterprise), without coil insertion, using local anesthesia. Conventional angiographic follow-up regularly disclosed excellent saccular occlusion and subsequent remodeling of stented arteries. LVIS-within-Enterprise double stenting may be of particular benefit in patients with VADAs, the Enterprise providing outer support to minimize stent bulging (as a fusiform aneurysm) as the inner LVIS reinforces flow diversion.


2021 ◽  
pp. 197140092110269
Author(s):  
Kenji Yatomi ◽  
Yumiko Mitome-Mishima ◽  
Takashi Fujii ◽  
Kohsuke Teranishi ◽  
Hidenori Oishi ◽  
...  

Purpose Among all stents available for neuroendovascular therapy, the low-profile visible intraluminal support stent bears the highest metal coverage ratio. We deployed a low-profile visible intraluminal support stent with a delivery wire or/and microcatheter system push action to shorten the low-profile visible intraluminal support stent and thus achieve a flow diversion effect. We report our single-institution experience with the use of low-profile visible intraluminal support stents for intentionally shortened deployment (shortening group) and non-shortened deployment (non-shortening group) for unruptured intracranial aneurysms. Methods We retrospectively reviewed the medical records of 130 patients with 131 intracranial aneurysms who were treated with low-profile visible intraluminal support stent-assisted coil embolization from February 2016–January 2019. All perioperative complications were noted. Every 6 months, we re-examined the patients with cerebral angiography or magnetic resonance angiography. The outcomes of aneurysm occlusion were evaluated by the modified Raymond–Roy occlusion classification. We used the finite element method and computational fluid dynamics to investigate the hemodynamics after shortened low-profile visible intraluminal support stent deployment. Results Immediately after treatment, the modified Raymond-Roy occlusion classification was significantly better in the shortening group than in the non-shortening group ( p<0.05). The latest angiographic outcomes showed the same tendency. Hemodynamic analysis by computational fluid dynamics suggested an adequate flow diversion effect with the use of our intentional shortening method. Conclusions Stent-assisted coil embolization using this technique showed good results of a high complete occlusion rate and low complication rate. These findings suggest that shortened low-profile visible intraluminal support stent deployment yields a flow diversion effect and may lead to early intra-aneurysmal thrombus formation.


2021 ◽  
Vol 73 (1) ◽  
Author(s):  
Magdy Algowhary ◽  
Mohammed Aboel-Kassem F. Abdelmegid

Abstract Background Stent manufacturers always record stent shortening data while they do not record stent elongation data. The aim of this study is to identify both stent shortening and elongation occurring after deployment in the coronary arteries and know their percentage. Results The length of coronary stents was measured by intravascular ultrasound (IVUS) by (1) edge-to-edge (E-E) length, measured from the appearance of the first distal strut to the last proximal strut, and (2) area-to-area (A-A) length, measured from the first distal struts seen at more than one IVUS quadrant to the last proximal struts seen at more than one IVUS quadrant. Stent shortening was defined as both E-E and A-A lengths were shorter than the manufacturer box-stated length (shortened group). Stent elongation was defined as both E-E and A-A lengths were longer than the manufacturer box-stated length (elongated group), otherwise unchanged group. Consecutive 102 stents deployed in ischemic patients were included. Stent elongation was detected in 67.6% (69 stents), and shortening was detected in 15.7% (16 stents), while unchanged stents were detected in 16.7% (17 stents). Although the 3 groups had similar box-stated length and predicted foreshortened length, they had significantly different measurements by IVUS, p<0.001 for each comparison. Differences from box-stated length were 1.9±1.4mm, −1.4±0.4mm, and 0.4±0.3mm, respectively, p<0.001. The elongated group had significantly longer differences from the corresponding box-stated and predicted foreshortened lengths, while the shortened group had significantly shorter differences from the corresponding box-stated length and similar foreshortened length. By multinomial regression analysis, the plaque-media area and stent deployment pressure were the independent predictors of the stent length groups, p=0.015 and p=0.026, respectively. Conclusions Change in stent length is not only shortening—as mentioned in the manufacturer documents—but also stent elongation. Stent elongation is dominant, and the most important predictors of longitudinal stent changes are plaque-media area and stent deployment pressure.


2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Naoki Hayakawa ◽  
Satoshi Kodera ◽  
Keisuke Takanashi ◽  
Shuichi Sahashi ◽  
Sandeep Shakya ◽  
...  

Abstract Background There is no consensus on the optimal guidewire passage route for femoropopliteal (FP) chronic total occlusion (CTO). If intraplaque wiring can be performed, a stent-less strategy using a drug-coated balloon can be realized even with FP CTO, and there is a high possibility that good expansion can be obtained even when stent deployment is performed. AnteOwl WR (AnteOwl) is a novel intravascular ultrasound (IVUS) device useful for navigating the second guidewire into the intraplaque route under IVUS observation from the subintimal space. Here, we describe representative cases of FP CTO in which CTO-specific IVUS was extremely useful. Case presentation Case 1 involved a 79-year-old man with total occlusion of the left superficial femoral artery (SFA). We used a contralateral antegrade approach, but the guidewire was advanced into the subintimal space. We advanced AnteOwl into the CTO. By utilizing the asymmetric structure of the transducer and the IVUS wire, we were able to reflect the positional relationship among the IVUS transducer, IVUS wire, and target plaque onto the angiographic image. By aiming the wiring in that direction, we succeeded in traversing the center of the plaque and finally succeeded in obtaining good expansion using the drug-coated balloon. Case 2 involved a 76-year-old woman with total occlusion from the SFA to the popliteal artery. We used an ipsilateral antegrade approach. When AnteOwl was placed on the wire and advanced to the popliteal artery, the subintimal space in the middle of the SFA could be visualized. We employed an IVUS-guided parallel wiring technique and succeeded in passing through all intraplaque routes. Although the CTO was long, we could easily advance through the intraplaque route by reflecting the information obtained from AnteOwl in angiography. Conclusions AnteOwl is an effective IVUS for FP CTO and facilitates a complex IVUS-guided procedure.


VideoGIE ◽  
2021 ◽  
Author(s):  
Eduardo Rodrigues-Pinto ◽  
Joel Ferreira-Silva ◽  
Pedro Pereira ◽  
Guilherme Macedo
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document