scholarly journals Optimization Packed Bed Column Reactor Parameters for Enzymatic Hydrolyzing of Lactose

Author(s):  
Sevim MAZLUM ◽  
Prof.dr İsmail BOYACI ◽  
Mehmet MUTLU
Catalysts ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 518
Author(s):  
Xiaohui Yang ◽  
Xudong Tang ◽  
Fengying Dong ◽  
Lin Lin ◽  
Wei Wei ◽  
...  

The novel carboxylesterase gene (est741) was cloned from Geobacillus uzenensis. The optimal pH and temperature of Est741 were 8.0 and 50 °C. Through site-directed mutation, the optimum temperature of the mutant M160K(EstM160K) was increased from 50 to 60 °C, and showed enhanced T1/2 of 2.5 h at 70 °C in comparison to the wild type (1.3 h). EstM160K was successfully expressed Pichia pastoris and EstM160K fermentation broth was directly immobilized on epoxy-functionalized supports via a one-pot strategy to obtain the immobilized enzyme lx-EstM160K. Additionally, lx-EstM160K showed enhanced T1/2 of 36.8 h at 70 °C in comparison to free enzyme. lx-EstM160K could degrade various pyrethroid pesticides. After 40 min reaction with 50 U of the lx-EstM160K, the malathion removal was 95.8% with a malathion concentration of 20 mg/L. When 2.5 g lx-EstM160K was added to the 10 mL column reactor with the concentration of bifenthrin was 500 mg/L and the transfer rate of the pump was 0.7 mL/min, the degradation rate of lx-EstM160K to bifenthrin was 90.4%. lx-EstM160K exhibited high operational stability and maintained 72% initial activity after ten batches of continuous reaction for bifenthrin pesticide biodegradation.


2015 ◽  
Vol 57 (28) ◽  
pp. 13307-13317 ◽  
Author(s):  
Z.H.M. Yadzir ◽  
M.Y. Shukor ◽  
A. Ahmad ◽  
M.S. Nazir ◽  
S.M.U. Shah ◽  
...  

2020 ◽  
Vol 8 (3) ◽  
pp. 8-13
Author(s):  
K. Thirugnanasambandham

Global warming due to greenhouse gases has become a serious global issue. Extensive efforts are being made to fighting this phenomenon through carbon capture as carbon dioxide (CO2) is its major contributor. This study focused on CO2 capture in packed bed column reactor using Poly-(D) glucosamine under the various process parameters such as temperature, feed flow rate and mass of the adsorbent. Statistical design of experiments was carried out in order to analysis the effect process parameters on the capacity of CO2 capture in packed bed column. The obtained results show that feed flow rate has the significant affect compared to others. The maximum of 956 mg of CO2 is captured under the following operating conditions; temperature of 40oC, feed flow rate of 30 ml/min and 0.25 g of the Poly-(D) glucosamine. The ability of Poly-(D) glucosamine to capture the CO2 in packed bed column is confirmed.


1988 ◽  
Vol 10 (11) ◽  
pp. 799-804 ◽  
Author(s):  
Ibrahim Che Omar ◽  
Naomichi Nishio ◽  
Shiro Nagai

2014 ◽  
Vol 4 (1) ◽  
pp. 9
Author(s):  
Monik Kasman ◽  
Shaliza Ibrahim ◽  
Salmariza Salmariza

Sign in / Sign up

Export Citation Format

Share Document